AQMS-650 -
Focused Photonics Inc.
FPI AQMS-650 measures NH3 in the ambient air, which delivers a stable and precise value. It adopts chemiluminescence technology with an external converter that can combine its use with AQMS-600 measuring NOx; during the measurement, NH3 will be converted into NO by oxidation. And it also comes with its own developed software. The remote PC software allows for a remote connection with a virtual interface and data downloading capability to operate the software.
-
NH3N -
Focused Photonics Inc.
uses international advanced sequence injection technology and combines it with the national standard method(GB7479-87); the structure is simple, with a low maintenance workload; it provides reliable, accurate ammonia nitrogen detection results. Such analyzer can operate continuously for up to 90 days without human monitoring, and it is with the functions such as automatic calibration, automatic zero adjustment, and automatic cleaning.
-
TPF-100 -
Focused Photonics Inc.
The TPF-100 product (Instrument/Apparatus) integrates a measurement module for three parameters: temperature, pressure, and flow rate. With only one measuring aperture, the compact design allows the measurement of three parameters, and its advantages include easy installation and maintenance.
-
EXPEC-1880 -
Focused Photonics Inc.
EXPEC 1880 infrared thermal imaging gas leak detector (EXPEC 1880) is a non-contact leak detector for volatile organic compounds (VOCs). It adopts a high-end mediumwave cooled type-II superlattice infrared detector and has passed Ex ic nc op IIc T4 Gc explosion-proof certification, with high protection level (IP54).
-
CDMS-1000 -
Focused Photonics Inc.
CDMS-1000 is designed with light scattering technology for continuous real-time measurement of particulate concentration along with noise and meteorological parameters. This combination consists of a particle analyzer, camera, sound level meter, and GPRS module.
-
AQMS-1000M -
Focused Photonics Inc.
The Compact system is the alternative solution against standard AQMS, it comes with integrated shelter consisting IPC, sampler, AC and all necessary accessories.
-
WOAS-1000 -
Focused Photonics Inc.
WOAS-1000 is the latest masterpiece done by FPI. It consists of a sampling module, sensors, power distribution unit, and data processing unit. The complete integration makes this system can be adopted in the various water matrix.
-
3000 Series -
Focused Photonics Inc.
FPI 3000 Series Water Quality Station is designed for online monitoring of water quality parameters in clean media. Equipped with a probe, controller, and pump, the mini-station can independently collect a water sample, analyze data, and transmit data to the central platform. This water station also can keep its sensor clear of fouling and calibrate it remotely via an inbuilt telemetry system.
-
CEMS-2000B -
Focused Photonics Inc.
Mercury analyzer applies cold vapor atomic fluorescence technology(CVAFS), integrated with dilution samplingsystem to eliminate interference with background components and ensure reliable performance. Automatic calibration of mercury check with internal CAL-200 calibration gas generator.
-
CEMS-4000 VOC -
Focused Photonics Inc.
CEMS-4000 VOC is an online emission monitoring system based on catalytic oxidation-FID technology, which can monitor volatile organic compounds (including total hydrocarbons, non-methane total hydrocarbons, etc.) in the flue gas. The system supports multiple installation methods, including wall-mounted installation, platform installation, cabin-type installation, etc. It can be widely used in the oil and gas industry, electronics industry, automobile manufacturing industry, and pharmaceuticals industry.
-
CEMS-2000 -
Focused Photonics Inc.
CEMS-2000 is a multi-gas monitoring system aimed to continuously and reliably measure emissions from various industrial combustions. The adoption of the hot-wet extractive method avoids the loss of content during sampling. The system is extendable with additional parameters upon request. All output signals proceed through the data acquisition system and then upload to the DCS or environmental authority server.
-
AQMS-3000 -
Focused Photonics Inc.
Micro AQMS gives a macro indication in terms of trend analysis against stationary AQI analysis. The micro AQMS is to find out the pattern of spatial pollution distribution during a certain period. These data support AQI results at the standard station, and most importantly, It gives a macro idea on municipal management.
-
AQMS-1000 -
Focused Photonics Inc.
FPI’s ambient air monitoring system consists of a sampling subsystem, a gas dynamic calibration subsystem, a meteorological parameters monitoring subsystem, a standard parameters monitoring subsystem, and a data acquisition and processing subsystem. It can monitor conventional air pollutants such as SO2, NO, NOX, CO, O3, PM2.5, PM10, etc. FPI also provides compact AQMS, micro AQMS, and mobile stations applicable to various customer needs.
-
EXPEC-2000 -
Focused Photonics Inc.
EXPEC-2000 VOC system is based on the principle of gas chromatography technology(GC-FID),it is of capable monitoring characteristic factors such as methane/non-methane hydrocarbons and benzene etc.
-
PMS-200M -
Focused Photonics Inc.
The PMS-200M particle multi-channel sampler accepts closed-loop response control technology to sample multiple gaseous and particulate samples simultaneously in the atmosphere. The PMS-200M can monitor meteorological parameters such as atmospheric humidity, pressure, temperature and wind speed in real time. The PMS-200M is configured with 4 sampling channels, which can be extended to 8 channels through stream and timing multiplexing.