Showing results: 16 - 30 of 69 items found.
-
Model T700U -
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Model T101 -
Teledyne Advanced Pollution Instrumentation
The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.
-
Model 430 -
Teledyne Advanced Pollution Instrumentation
Teledyne API, a recognized leader in Ozone measurements, is pleased to offer the Model 430 O3 Monitor. The 430 is a compact instrument that uses the proven UV-absorption principle. The small footprint and robust design make it ideal for a variety of applications where portability and accuracy are both necessary.
-
Model T102 -
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
Model N200H -
Teledyne Advanced Pollution Instrumentation
The Model N200H uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
Model T200UP -
Teledyne Advanced Pollution Instrumentation
The Model T200UP provides trace level measurements of NO and NO2 using our Model T200U NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.
-
Model N400 -
Teledyne Advanced Pollution Instrumentation
The Model N400 Ultraviolet (UV) Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air. A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.
-
Model T703U -
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Model T200U -
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.
-
Model T200M -
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
Model T500U -
Teledyne Advanced Pollution Instrumentation
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.
-
Model T200P -
Teledyne Advanced Pollution Instrumentation
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
-
Teledyne Advanced Pollution Instrumentation
Teledyne API's Carbon compound analyzers utilize Gas Filter Correlation combined with reliable NDIR (non-dispersed infrared) technology to produce very stable and accurate gas measurements. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
Model 751H -
Teledyne Advanced Pollution Instrumentation
The Model 751H is a portable, fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with sensitive analyzers in ambient background and trace level applications. Packaged in a wheeled, high density plastic case, the Model 751H provides ultra-high purity output with a warm-up time of 30 minutes.
-
Model N200 -
Teledyne Advanced Pollution Instrumentation
The Model N200 uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases.