ECOPIA
One of the leading company in semiconductor testing equipment by man ufacturing Hall Effect Measuring system, Probe Station, RTA or RTP, LED tester, manipulator and etc..
- 82-505-389-1999
- 82-505-389-1996
- 7th Floor Gyeondgo Bld.
986-18
Hogye-dong, Dongan-gu, Anyang City, Gyeonggi-do 431-841
Korea, South
Filter Results By:
Products
Applications
-
product
Hall Effect Magnet Kit
Permanent magnet - Neodium materials - +/- 0.03Tesla deviation can be made in a process of assembling magnet. - However, we indicates correct tesla strength measured by gaussmeter, before shipping magnet kit.
-
product
Probe Station
EPS500
Reasonable price and compact design. - Sellectable chuck size : 4inch, 6inch, 8inch when ordering probe station. - Hot chuck can be installed. Temp range: RT ~ 300°C - Hot and cool chuck from 0 °C ~ 300 °C can be provided. - Maximum 6pcs of manipulators can be installed on the base unit of probe station EPS500.
-
product
Probe Station
DARK BOX
Size : 750 × 660 × 660 mm - Material : Steel - We can provide various dark box in size and shape at reasonable price as per customer requirements.And we also provide “integral sphere” with probe station as below.
-
product
Probe Station
ETCP1000
Installation of “Hot and cool chuck” - Sellectable chuck size : 4inch, 6inch. - Temperature variation : -193°C ~ 300°C (80K ~ 573K) - Additional requirements : Vacuum chamber, LN2 tank(Bombei), microscope, CCD camera, manipulators. - EPS500 is standard model in ETCP1000 probe station.
-
product
Probe Station
EPS300
Reasonable price and compact design. - Sellectable chuck size : 4inch, 6inch, 8inch when ordering probe station. - Hot chuck can be installed. Temp range: RT ~ 300°C - Hot and cool chuck from 0 °C ~ 300 °C can be provided.
-
product
Probe Station
EPS1000
Reasonable price and compact design. - Sellectable chuck size : 4inch, 6inch, 8inch when ordering probe station. - Hot chuck can be installed. Temp range: RT ~ 300°C - Hot and cool chuck from 0 °C ~ 300 °C can be provided. - Maximum pcs of manipulators can be installed on the base unit of probe
-
product
Spring loaded type sample mounting board
SPCB
Mount samples on SPCB board without bonding wires.Spring loaded clamps helps to move probe pin easily x, y, z direction.Gold plated Non-magnetic phosphor-bronze constructionContacts on sample’s four point corner by soldering materials, such as InSn may still be required for good ohmic contact.
-
product
Photonic Hall Effect
HMS7000
Classic hall effect measurement system is to read voltage difference made between both diagonal sides, when flowing current and applying magnet field strength, in perpendicular to flowing current direction. - Photonic hall effect measurement is to read various electrical properties by illuminating light of “various range of wavelength” on the sample, in addition to flowing current and applying magnet field strength. - It is great to see “RGB (Red, Green, Blue), Light intensity vs carrier density, carrier mobility, resistivity, hall coefficient”
-
product
Resistivity Test System
RMS-1000
Accurate and powerful performance. - Possible to get much accurate resistivity value by taking 8 raw data. - Good to check ohmic contact by flowing forward and reverse current.2. We provide various sample mounting board and probe head and tips.3. We have an optional item which can measure in variable temperature. - Room Temperature ~ 300dC.
-
product
Rapid Thermal Processing system
RTP - 1300
Ecopia’s RTP (Rapid Thermal Processor) is able to do heat treatment on maximum 4inch wafer in very high speed. And, we have installed 12 pcs of hallogen lamps and it can make it possible to do heat treatment on the sample uniformly.Furthermore, it is very convenient to use and we are providing at reasonable price. Therefore, it is good to use in university and laboratory.
-
product
Super high temperature hall effect measurement system
Super high temperature hall effect measurement system that is useful to flow gas into chamber with sample. - Newly developed furnace that makes it possible to increase over 800 and use for measuring hall effect. - Gas flow control system in order to flow various gas. - Sample holder for high temperature. (keep the good contact on 800) - High Temperature control system (DC power) On condition of specific temperature with gas flow , new semiconductor materials have been developed to see electrical property's change.
-
product
Hall Effect Measurement system
HMS-5500
Variable temp : 80K ~ 350K (model# : AMP55T ) - HMS-5500 can be compatibly used with both low temp magnet kit (model# :AMP55T) and high temp magnet kit (model#: AHT55T5, upto 500dC) - Below image is to show model# HMS-5500 + AMP55T, for low temp.
-
product
Hall Effect Measurement system
HMS-3300
Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.
-
product
Hall Effect Measurement system
HMS-5300
Variable temp : 80K ~ 350K (model#: AMP55T ) - HMS-5300 can be compatibly used with both low temp magnet kit (model# : AMP55T) and high temp magnet kit (model# : AHT55T3, upto 300dC). - Below image is to show model# HMS-5300 + AMP55T, for low temp.
-
product
Hall Effect Measurement system
HMS-3000
Hall Effect Measurement System is very useful for measuring Carrier Concentration, Mobility, Resistivity and Hall Coefficient that should be pre-checked in order to grasp the electrical specifications of semiconductor device. Therefore, it is essentially required system to understand the electrical characteristics of semiconductor device.Ecopia’s HMS series consist of constant current source , terminal conversion system by Van der Pauw technique, low temperature(77K) test system and magnetic flux density input system. So, it is well-established system that has all the things needed to Hall Effect Measurement System.