M. C. Miller Company

The M. C. Miller Company is a recognized leader in the corrosion control industry, from the provision of products employed to monitor the effectiveness of cathodic protection systems, to the provision of specialized kits for corrosion testing in a variety of applications

  • (772) 794-9448
  • (772) 589-9072
  • sales@mcmiller.com
  • 11640 U.S. Highway 1
    Sebastian, FL 32958
    United States

Filter Results By:

Products

Applications

Showing recent results 1 - 15 of 15 products found.

  • JR-1

    12820 - M. C. Miller Company

    • 35 Amp relay [@ 24VDC max. or @ 48VAC max.]• Crystal controlled timing• Rechargeable battery• Immediate or delayed interruption operation• Low battery indicator• Countdown and relay status indicators• On and off cycle times up to 999.9 seconds• Synchronized operation with any number of JR-1's and JR-2's

  • JR-2

    M. C. Miller Company

    100 Amp (Mercury) relay [@ 48VDC max. or @ 120VAC max.]• User Selectable input voltages (100VAC, 120VAC, 230VAC and 240VAC• Crystal controlled timing• Rechargeable battery• Immediate or delayed interruption operation• Low battery indicator• Can be clock synchronized with other JR-2 units or with JR-1 units.• Synchronization better than 1 millisecond.

  • LC-4.5 Voltmeter

    5203 - M. C. Miller Company

    Model LC-4.5 is the first hand-held voltmeter to include a number of special features which facilitate corrosion and cathodic protection testing on underground structures. It is designed for field testing under almost any environmental conditions. Sealed Mil Spec. switches, sealed windows, a gasketed case and a printed circuit board with baked-on moisture and fungus resistant coating on both sides make this possible.

  • Analog Tank Test Kit

    4108 - M. C. Miller Company

    The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.

  • Cronos Controller Unit

    12950 - M. C. Miller Company

    Rugged M. C. Miller Co. design, highly reliable, easy to operate and verycompetitively-priced.• Precision clock-timing even with an intermittent view of the GPS satellites.• Two years of continuous (current interruption) operation on a single set of replaceable "D" cell batteries - no need to recharge the unit every few days

  • Concrete Corrosion Mapping System

    15620 - M. C. Miller Company

    Our Concrete Corrosion Mapping System (CCMS) can be used to satisfy the ASTM C-876 standard test method and the kit contains all equipment items that are needed to perform a corrosion survey on virtually all types of reinforced concrete structures, such as bridges, highway slabs and parking garages.

  • Buried Casing-to-Pipe Insulation Checker

    461000 - M. C. Miller Company

    Built to provide years of dependable service, this precision instrument is light and compact.

  • 40 Amp Cronos

    12955 - M. C. Miller Company

    Rugged M. C. Miller Co. design, highly reliable, easy to operate and very competitively-priced.• Precision clock-timing even with an intermittent view of the GPS satellites.• Two years of continuous (current interruption) operation on a single set of replaceable "D" cell batteries - no need to recharge the unit every few days

  • Digital Tank Test Kit

    4109 - M. C. Miller Company

    The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `

  • Data-logger

    11250 - M. C. Miller Company

    Comes loaded with M. C. Miller's Test Site Survey application• Integrates with ProActive, M. C. Miller's corrosion control data management application• Data-types are customizable for each of your test sites and each test site can be GPS position stamped • High-resolution date/time stamped photos can be taken at your test sites during a route and recorded images are posted directly to the ProActive database • Sub-meter GPS position resolution

  • Data-logger

    11275 - M. C. Miller Company

    Comes loaded with M. C. Miller’s Pipeline Survey software application for “Over-the-Pipe” Surveys:• Close Interval Potential Surveys (CIPS or CIS)• DCVG Surveys• Combined (single-pass) DCVG/CIS Surveys• Surface Potential Surveys

  • Electrode

    14905 - M. C. Miller Company

    Highly durable, large area ceramic plug (2.25" diameter) - protective plastic cap included. • Copper/Copper Sulfate Electrode can be used in any orientation, including upside down configuration. • Ideal for concrete corrosion potential mapping (bridge decks, parking garages, etc.) - stands upright by itself. • Electrode supplied with highly absorbent sponge cap for enhanced electrical contact to concrete surfaces. • Supplied with a charge of copper sulfate crystals inside the Lexan tube

  • Model PS-1

    16820-100 - M. C. Miller Company

    The Model PS1 under tank probe is designed to be used in conjunction with customer-supplied ¾” National Pipe Thread (NPT) PVC piping and the product has a ¾” (NPT) threaded end that accepts a standard coupling. Any number of pipe pieces can be combined via couplings to provide the required probe insertion length under a tank. The probe can be combined with any standard reference electrode with a ¼ x 20 threaded fitting, including the RE-5, RE-5C and RE-7 portable reference electrodes. Reference electrodes are sold separately. The sealed cable to be fed through a customer-supplied PVC pipe comprises #16 AWG wire with red colored PVC insulation and the wire length can be selected via the radio buttons in the field below.

  • Miller 400D

    44550 - M. C. Miller Company

    No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)

  • Miller 400A

    44500 - M. C. Miller Company

    Rugged, lightweight case - safe to use on wet ground• Weatherproof, even with lid removed - IP67 rating for dust and water intrusion• Convenient case lid removal for ease of movement, with test leads attached, to new measurement locations• Resistance measurement range from 0.01Ω to 1.1MΩ • Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 97Hz (the unit’s operating frequency)• Runs on a set of C-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source