Showing results: 1 - 15 of 79 items found.
-
CAT Standard Series -
Amperis sl
The CAT Standard series circuit breaker analyzers & timers are stand-alone or a PC-controlled digital instruments for circuit breakers condition assessments. The timing channels record closing and opening of the arcing, resistor, and auxiliary contacts. CAT Standard series records graphs of both, trip and close coil currents and displacements of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the pre-insertion resistors (if present in the circuit breaker). Test results can be downloaded to a USB memory stick or saved to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Test results can also be printed on the 80 mm (3.15 inch) thermal printer (optional accessory) in tabular and graphical form. CAT Standard series provides an easy selection of different operational modes:
-
CoroCAM 8 UAV -
Amperis sl
*High-sensitivity UV detector, which can detect UVc light at 2.05×10-18 Watt/cm2, this allows detection of the smallest corona discharges.*9Hz (or 25Hz optional) IR radiometric camera module*Control of a limited number of camera functions from a standard RC controller using PWM or SBUS.*Remote control of all camera functions from the laptop via an Ethernet link.*Soft sync or staggered zoom of the 3 channel cameras. The IR and UV channels are digitally zoomed in, which is visible...optically zoomed in to the minimum FOV, and then digitally zoomed out.
-
CoroCAM 8 -
Amperis sl
This model of the crown effect camera family is the most advanced on the market. It combines a high specification visible camera, an infrared camera and an ultraviolet camera. The great advantage is the possibility of performing thermal and ultraviolet inspection simultaneously with the consequent benefit in terms of savings (in time and effort).
-
CAT-H Series -
Amperis sl
The operation of the breaker can be initiated in different ways (e.g. from a control room, by a local breaker or externally by a test device) depending on the test conditions. Various time measurement triggers are available to record a measurement under a different test condition:*Coil control channel*Continuous current clamping channel*DC voltage channel
-
AMZC-310S -
Amperis sl
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
AMIC-5010 -
Amperis sl
Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits
-
AMIC-2505 -
Amperis sl
Measurement of insulation resistance: 500,1000 and 2500V (2TΩ) ; 2 and 3 wire method ; Measurement of DC and AC voltages at 0...600V ; Measurement of leakage currents
-
AMIC-10k1 -
Amperis sl
Insulation resistance measurement - 40TΩ: * 50 - 1000 V, in 25 V steps, * 1000 - 10000 V, in 50 V steps ; Memory, bluetooth keyboard option, heating location ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits.
-
AMIC-5005 -
Amperis sl
Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current ;Function with digital filter
-
AMIC-10 -
Amperis sl
The AMIC-10 digital insulation resistance meter is used for direct measurements of the insulation resistance of electrical equipment working with voltage up to 1 kV. In addition, this meter makes it possible to measure compensation and protective connections, low-voltage resistance measurements and DC and AC voltage measurements.
-
RMO-A -
Amperis sl
These devices can store internally up to 500 measurements marked with date and time. The equipment is accompanied by the DV-Win software to treat the data as an Excel sheet to show them as a diagram, passing the data via USB (or optionally via Bluetooth or RS232.
-
AE865C -
Amperis sl
This lightweight cart mounted Mini-Degasser uses the latest high vacuum technology for filtering, dewatering and degassing of insulating and dielectric fluids. The equipment is ideal for processing oil in transformers and other similar locations.
-
AMPI-520 -
Amperis sl
The AMPI-520 digital meter is designed to measure impedance in short-circuit loops without tripping the differential protection, it also measures the protection tare, earth resistance, continuity and phase sequence check.
-
MPI-530-IT -
Amperis sl
Short circuit loop measurement:*impedance measurement with 23 A (44 A phase-to-phase), short circuit resistance Rzw=10Ω,*measuring range: 95...440V, frequency 45...65 Hz,
-
AMPI-525 -
Amperis sl
*Short circuit loop measurement:*Impedance measurement with 23 A (44 A phase-to-phase), short circuit resistance RZW =10Ω*Measuring range: 95...440V, frequency 45...65 Hz*Short circuit loop measurement with resolution 0,01 Ω , without tripping the differential protections (I∆n ≥30mA)*Automatic short-circuit calculation, phase-neutral and phase-phase voltage detection