6237 DLRO -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measure down to 1μΩ.● 6 ranges from 2.000mΩ to 200.0Ω.● Maximum resolution of 1μΩ.● Three test currents with over-temperature protection.● Four terminal measurement.● Protection against inadvertent connection to over- voltage. (crow bars for current and voltage)● Clear & large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave™ Inside.● EnerSave™ Auto-hold.● EnerSave™ Auto-off.● Rechargeable battery operated● Robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.
-
-
4136 mO -
Standard Electric Works Co., Ltd
● Protection class: IP66 (Lid closed)● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.
-
8012 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Extra large LCD(78 × 67mm).● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Auto power off.● Auto off and off override.● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.●Frequency measurement indication.
-
4103 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.
-
LVD-415 -
Standard Electric Works Co., Ltd
● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.
-
ST-2004 -
Standard Electric Works Co., Ltd
● Big-size liquid crystal display.● 3 ¾ digital LCD with a maximum display of 3999.● Bar-graph LCD.● Back light function.● Data hold function.● Auto-ranging design.● Range change function.● Relative/Maximum/Minimum modes.● Peak hold mode.● VAHz mode measures frequency in voltage or current mode.● 40M Hz frequency counter.● Auto power off.● Continuity check.● Low battery indication.● Over range indication.● Fuse protection.● Easy-to-carry handle that doubles as a convenient stand.● Robust case.● Holster is optional.
-
1811 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Suitable for industrial applications.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto off and off override.● Polarity Trip indicator (Positive of Negative Phase).
-
2751 IN -
Standard Electric Works Co., Ltd
● Timer for test function (count 3-5 minutes).● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338”) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● Data hold function● Auto power off function.● BS 16 edition.
-
6410 DM -
Standard Electric Works Co., Ltd
● 3000 counts with a maximum display of 2999.● Angled display design helps the user to identify the reading of value easier.● Auto scanning function for AC/DC voltage, and current.● Auto ranging.● Range change function.● Continuity check.● Diode & Capacitance measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.
-
PC7k, PC11k, PC22k, PC33k, PC44k -
Standard Electric Works Co., Ltd
● No user’s assembled parts.● Dual color-coded scale (%, Vac).● Neon indicator when >1200Vac.● Lightweight, robust & compact.● Carry case included.● Compare between phases.● Measure and test phase to earth.● High quality fiberglass wound rod.● Self powered operation. No battery required.● DC version available.● Measure phase to phase.● Hi immunity to interference fields.● Suitable for indoor and outdoor use.● Current is limited to ±1 milli-ampere.● Grounded or ungrounded systems.● Meets IEC 61481 (excludes PC44K).
-
1107 IM -
Standard Electric Works Co., Ltd
● Large LCD : 68 × 34mm(2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.
-
855 PRB -
Standard Electric Works Co., Ltd
● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.
-
189 DM -
Standard Electric Works Co., Ltd
● 4000-count LCD.● Auto ranging.● Voltage, Resistance, Continuity, Diode measurement.● Frequency, Capacitance, Current measurement.● Wide range for capacitance test : 0~4000μF.● Data hold function.● Low battery indication.● Over range indication.● Auto power off.● With a convenient stand for viewing.● Compact and lightweight.
-
HLV-3 -
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.