Showing results: 91 - 105 of 345 items found.
-
-
887 PR -
Standard Electric Works Co., Ltd
● Indicates phase rotation. ● Indicates phase presence.● No battery required.● Phase rotation phase presence indicated on large liquid crystal display.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 40Vac to as high as 600Vac.● Fused.● Lightweight, robust and compact.● EN 61010-1 CAT III 600V EN 61010-2-032
-
ST-2000 Hz -
Standard Electric Works Co., Ltd
● Principle : Frequency sensing transducer● Accuracy : ±0.5% of full scale value on 45 to 65 Hz range ±0.5% of full scale value on 0 to 100Hz range ±0.5% of full scale value on 0 to 500Hz range● Scale Length : Approx. 135mm (5-3/8”)● Case Material : Bakelite with glass window
-
3000 MPR -
Standard Electric Works Co., Ltd
● 4000-count LCD● Auto ranging● Voltage, Resistance, Current, Continuity, Diode measurement● Can measure Resistance up to 200.0 Mohm● Checks a wide range of 3-phase power sources (80~750VAC)● Phase Rotation indication : clockwise and counter-clockwise on LCD● The LCD will show AC voltage between phases and Phase Rotation● Wide range for capacitance test: 0~40000μF(40.00mF)● REL / Auto-Zero function● MAX /MIN function● VAHz function● Frequency : 40.00 MHz● Data hold function● Over range indication● Low battery detection● Auto power off in 15 minutes● Convenient stand for viewing● Comply with EN 61010-1, CAT III 600V for the range of 600V AC/DC
-
2804 IN (Ranges: 1kV, 2.5kV, 5kV, 10kV) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.
-
4105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
ST-80 -
Standard Electric Works Co., Ltd
● DC up to 50A● AC up to 50A● Hz Meter : Measuring Ranges : 45~55 Hz, 45~65 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0● Case and Composition: Acrylic resin front. Bakelite case. Four studs mounting.● Accuracy :DC : Class 2.0 AC : Class 2.5 Rectifier : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
1612 EL -
Standard Electric Works Co., Ltd
●Microprocessor-controlled●Extra large LCD (78 × 67mm)●Very low power consumption●50Hz and 60Hz operation●Accurate digital readout of disconnection time●Over temperature protection●Over voltage protection●Fuse protection●Zero crossing circuitry permits testing at 0° or 180°●Auto power off●Backlight function●Wiring polarity indicator●Measures voltage between Line and Earth before testing●Frequency measurement indication
-
ST-3501 -
Standard Electric Works Co., Ltd
● Display: 3½ digit liquid crystal display (LCD) with max. reading of 1999.● Polarity: Automatic, (-) negative polarity indication.● Zero Adjustment: Automatic.● Over Range Indication: Highest digit of (1) or (-1) is displayed.● Low Battery Indication: The (BAT) is displayed when the battery voltage drops below the operating voltage.● Measurement Rate: 3 measurements per second, nominal.● Operating Temperature: 0°C to ±50°C, 0-70% RH.● Storage Temperature: -20°C to +60°C, 0-80% RH, with battery removed.● Accuracy: Accuracy specifications at 23±5°C, less than 75% RH.● Power: Single, 006P 9 volt battery● Dimensions: 128(L)×72(W)×33(D)mm.● Weight: Approx .200g
-
3920 CL -
Standard Electric Works Co., Ltd
● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Low battery indication.
-
1154 TMF -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
1152 MF-M -
Standard Electric Works Co., Ltd
● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ratio (DAR).● BS 16 edition.
-
191 CBI -
Standard Electric Works Co., Ltd
● 191 CBI is an easy tool to find the circuit breaker or fuse supplying electrical power to an outlet or lighting fixture. Just plug the transmitter into the outlet.● Use the receiver to scan the circuit breaker panel box. An audible tone will be clearly heard when the right circuit breaker is scanned.● The plug of transmitter is changeable. The plug of transmitter could be changed for customers' requirement from different countries.
-
8010 IN -
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1
-
810 EL -
Standard Electric Works Co., Ltd
● Wiring check.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● Sense automatically 50 or 60 Hz.● No battery required.● Simple operation.● Current injected in phase with the voltage.● Fused.● Wide operating voltage (195Vac to 265Vac).● Other voltage optional (110V).● Robust.