Showing results: 121 - 135 of 345 items found.
-
ST-123U -
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.
-
8052 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on “low ohms” : 3Ω & 500Ω.● AC voltmeter with linear scale up to 600 Vac.● 200mA short circuit current for continuity.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display of external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Supplied with high quality test leads.
-
ST-95 -
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : ± 2.0% full scale● Case and Composition: ABS case and PC cover Four studs mounting● Accuracy : ± 2.0% full scale value● Color:Black case and white scale plate.● Pointer:Knife-type, color in black.
-
ST-90U -
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.
-
6280 TB -
Standard Electric Works Co., Ltd
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1
-
2801 IN -
Standard Electric Works Co., Ltd
● Microprocessor-controlled with advanced safety features.● Three test voltages : 250 / 500 / 1000V.● Displays and sound warning if external voltage present.● Ener-Save™ feature to extend battery life.● Continuous battery monitoring.● Auto ranging / auto-null / auto-off.● Insulation tested at 1mA.● Built-in carry case, test leads in separate pouch.● Real-time barg-raph display of test voltage and voltage decay during discharge.● Audible and visual message displayed if external voltage is present.● Large LCD.● Display can be customized for special orders.● Continuity buzzer.● Show test time duration (up to 99.9s) for easy comparison.● BS 16 edition.
-
ST-2001 ACV -
Standard Electric Works Co., Ltd
● Big-size LCD (112 x 59mm)● Backlight function.● Analog scale with Bar-graph for viewing. (100 bars)● 10000 counts (high resolution).● DCV Ranges: 99.99mV~999.9V (ST-2001 DCV). ● ACV Ranges: 99.99mV~800.0V (ST-2001 ACV). ● 5 manual ranges controlled by rotary switch.● Data Hold function● Low battery indication● 9V power supply● Best resolution of 0.01mV (10uV)● Precision meter for factory maintenance, field servicing and educational purposes.● With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)● 2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)● Well isolated to contact. (DCV-R & ACV-R)● The software is included (Compact disc). (DCV-R & ACV-R)
-
4310 IN -
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
-
-
285 HD -
Standard Electric Works Co., Ltd
● Three different ranges of identification of AC voltage: 285-A HD : 3~7 kV 285-B HD : 6.6~11 kV 285-C HD : 10~22 kV● The LCD will "flash continuously" for high voltage testing.● Physical contact with electrical conductors is not nec- essary when testing for live wires.● The 285 HD senses the radiated field that surrounds live conductors.● Radiated field strength increases with voltage and decreases quickly with distance.● Large LCD.● Continuous monitoring.● Easy to install.● No batteries required.● Weight : Approx. 80g.● Meets EN 61326-1 EN 55011 EN 61000-4-2 EN 61000-4-3
-
180 CB -
Standard Electric Works Co., Ltd
● The Amplifier Probe is designed to identify and trace wires or cables within a group without damaging the insulation.● Works with any Tone Generator to identify wires.● Volume control for increased sensitivity and adjustable to suit work environment.● Recessed ON/OFF button prevents battery drain.● A phone jack is designed for headset or handset.
-
2330 LX -
Standard Electric Works Co., Ltd
● Wide range for measurements up 40000 lux and 4000 fc.● 0.01 lux and 0.001 fc resolution for accurate low light level measurements.● Light sensor cover is included for preserving sensor life.● Auto off function.● Data hold function.● Low battery indication.● Over range indication.● Auto-ranged.● Manual-ranged.● Calibration mode is provided.● 9V battery system.● Selection key for lux and fc.● The spectral sensitivity close to CIE photopic curve.● Ideal tool for workplace, clean-room and computer room light testing.● Video, photographic, office, classroom, and architectural uses.
-
2713 PU -
Standard Electric Works Co., Ltd
● Designed to proof: -Phasing sticks. -High voltage detectors (contact type only, not to be used with non contact proximity detectors.) -High voltage and voltage testers.● Battery operated.● Led indicates when power is “ON”.● Small and hand-held.● Quick connection with normal 4mm test leads.
-
HLV-2 -
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.