Chroma Systems Solutions, Inc.

World recognized leader in power supply testing equipment which includes automated power supply test systems, electronic loads, programmable AC power supplies and related equipment to support the power conversion industry.

  • 949-600-6400
  • 949-600-6401
  • customercare@ChromaUSA.com
  • 19772 Pauling
    Foothill Ranch, CA 92610
    United States

Filter Results By:

Products

Applications

Showing recent results 1 - 15 of 55 products found.

  • Chroma LCR Meters

    Chroma Systems Solutions, Inc.

    Some of the key features to look for in an LCR meter (also known as an impedance meter) are: accuracy, test frequency, measured parameters, test voltage and test current. Additionally, an easy to understand display of test results and the ability to access and use these results has become increasingly important. Component testing often requires much more than simply a resistance, capacitance or inductance value at a given test frequency and stimulus voltage. An LCR meter or impedance meter must have the flexibility to provide multi-parameters over wide frequency and voltage ranges.

  • Chroma Milliohm Meters

    Chroma Systems Solutions, Inc.

    The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.

  • Chroma Thermoelectric Instruments

    Chroma Systems Solutions, Inc.

    Chroma’s Advanced TEC Controllers have an excellent temperature monitoring engine and allows for 2 T-type thermal couple inputs. The cold junction of the engine is internally stabilized up to 0.001℃ regardless the size and geometry of thermal platforms. The TEC driver uses a filtered PWM architecture, which obtains 150W, 300W high driving power efficiency with a smooth current modulation to a DC-like output. More TEC driving power means a wider temperature range, faster temperature response, and larger platform applications.

  • Modular DC Power Supply

    62000B - Chroma Systems Solutions, Inc.

    Voltage range: 1 ~ 150VCurrent range: Up to 2000A (System)Power range up to 1.5KW per module up to 120KW per systemHigh Power Density (464 mW / cm3 = 7.13 W/In3)N+1 RedundancyHot-swappableIdeal for Burn-in & PlatingRemote SenseRemote ON / OFFCAN Bus ControlDC OK Signal Output

  • Low Power Programmable AC Source

    61600 Series - Chroma Systems Solutions, Inc.

    Power:500VA (61601)1000VA (61602)1500VA (61603)2000VA (61604)4000VA (61605)Voltage range: 0-150V/0-300V/AutoFrequency: 15Hz 1000HzCompact size and weight attributable to advance PWM technologyBuilt-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage, current limitOne-key recall for 9 different voltage and frequencyLow output impedance for testing IEC 61000-3-2 ( 61605 )Comprehensive measurement capability, V, Irms, Ipk, Inrush, P, Q, S, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates ON/OFFAnalog programming interface3 units combined to 3-phase power outputEasy-use software for operation and ON/OFF testOptional GPIB and RS-232C interfaceFull protection: OP,OC,OV and OT protection

  • Multi-Channel Digital Power Meters

    66203/66204 - Chroma Systems Solutions, Inc.

    Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders

  • Impulse Winding Tester

    19301A - Chroma Systems Solutions, Inc.

    10V~1000V impulse voltage test, with 0.25V test resolutionHigh impulse test sampling rate (200MHz), 10bitsHigh/Low inductance test (0.1uH~100uH)Inductance contact check functionInductance differential voltage compensation functionBreakdown voltage analysis functionLow voltage range to increase the sensitivity of waveform analysis (32V/64V/128V/256V/512V/1024V)USB port for storing waveform & screen captureMulti-language, graphical color displayStandard LAN, USB, and RS232 interfaces

  • Milliohm Meter

    16502 - Chroma Systems Solutions, Inc.

    Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface

  • Hipot Testers, Electrical Safety Analyzers, Ground Bond Testers, & Impulse Winding Testers

    Chroma Systems Solutions, Inc.

    Hipot or dielectric withstand testing instruments manufactured by Chroma are used for conducting electrical safety tests on electrical components and products to make certain they are in compliance with IEC, UL, TUV, CSA, EN, and other electrical safety requirements. In addition, these instruments are designed for general product or component testing as well as complex medical safety testing (60601-1) ensuring human safety and product reliability.New hipot and electronic safety test instruments (EST) purchased in North America are backed by a 2-year standard warranty. This warranty assures that new Chroma EST instruments will be free from defects in workmanship for a period of up to two years from the date of shipment. For years we have been providing the best value possible when it comes to your electrical testing needs: hipot testers, electrical safety analyzers, ground bond testers, and wound component testers are no exception.

  • Hybrid Wound Component EST Scanner

    19035 - Chroma Systems Solutions, Inc.

    The Chroma 19035 Series supports 5kVac/6kVdc high voltage output to conform with withstand voltage test requirements for wound components, and has a maximum output current up to 30mA. The Insulation Resistance (IR) test measurement ranges from 1M to 50G, and voltage output can be up to 5kV; while the DCR test can measure the resistance parameters of wound components and test circuit connections (contact check) before the withstand voltage test is performed.

  • High Frequency LCR Meters up to 30MHz

    11050 - Chroma Systems Solutions, Inc.

    The Chroma 11050 Series HF LCR Meter is a precision test instrument designed to accurately measure and evaluate passive components at high speeds. Its measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components. The HF LCR Meter has a broad testing frequency range 75kHz~30MHz/1kHz~10 MHz/60Hz~5MHz suitable for analyzing component characteristics under different frequencies. Its 0.1% basic measurement accuracy provides stable and highly reliable results. A fast 7ms measurement speed effectively increases productivity when working in an automated environment.

  • High Power Programmable AC Source

    61610 - Chroma Systems Solutions, Inc.

    Power Rating:61511/61611: 12KVA61512/61612: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation

  • High Power Programmable AC Source with Transients

    61510 - Chroma Systems Solutions, Inc.

    Power Rating:61511: 12KVA61512: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation

  • 16 Channel Battery Cell Tester

    17216M - Chroma Systems Solutions, Inc.

    Chroma’s 17216M is a standalone 16 channel version of their 17011 series high precision charge/discharge tester specifically designed for Lithium-ion batteries, electrical double layer capacitors (EDLC), and lithium-ion capacitors (LIC). Suitable for product characteristics screening, cycle life testing, incoming and shipping inspection, material experiment, and balancing battery voltages.

  • Power Conversion Automated Test Platform

    C8000 - Chroma Systems Solutions, Inc.

    Power conversion testing is our core competency. Chroma's engineering delivers cost-effective automated test system and software platforms to fit your Design Validation Testing (DVT) in the lab or High Speed Functional Testing in the production line.