OptCom Company, Ltd
Optcom plans to provide measurement technology centering on light measurement, to challenge unknown regions such as in infor- mation transmission and measurement technology by improving manufacturing tech throughout the entire photonics industry and in this way help people build richer lives.
- +81-538-21-8600
- +81-538-21-8602
- 141-1 Tomigaoka,
Iwata,, Shizuoka. Pref., 438-0803
Japan
Filter Results By:
Products
Applications
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
product
Goniophotometer
GMS2000
In this goniophotometer, the tested luminaire rotates in the prescribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously. The combined motion of the luminaire and mirror permit luminous measurement at the direction of any horizontal or vertical angle without tilting the luminaire, therefore, the luminous intensity will be not variation. The photometer head located at a fixed position of the limiting photomet- ric distance in front of the reflecting mirror to gather the light in each direction.
-
product
LED LIGHT DISTRIBUTION TESTER
Essential elements among LED inspection categories are the light quality and intensity. Accurate measuring for optical characteristic requires diverse photo-measurement technology which fits into production lines. This system extracts conditions necessary for optical measuring optical characteristics on production equipment through accurate measurement both of the quality and of intensity of LED light distribution characteristics.
-
product
2D Color Temperature Tester
LCC-900
Screens the pass/fail results or module type LED image information that is automatically reset via data transfer with handler unit. Data results are stored in server for unified management.
-
product
O-E PROBE
O-E probe is the unit to convert optical signals to electrical signals. It can be connected to Oscilloscopes or data loggers via a BNC connector and monitor the conversion waveform. It can acquire the optical signal easily by just pointing the optical fiber probe at the light source. Recently, more and more light sources utilize optical modulation for next generation lighting such as LED. Acquiring the emission timing is required to measure the emission phenomenon of the light source. This O-E probe unit is the ideal tool for these tasks.
-
product
Spectrometer
LSCM
This device performs high-speed measurement and sorting of LED electrical and optical characteristics while synched with control signals from the LED production line inspection and sorting system. The LSCM then provides that pass/fail information to the system. The LSCM is equipped with the function to test both electrical and optical characteristics by applied voltage and current to the LED. This test device was designed to integrate test functions required by the inspection and sorting system into one compact body.
-
product
Measuring System for Assessment of Optical Radiation Safety
IEC62471
The system is designed especially for the determination of optical radiation hazard exposures specified in IEC62471, such as actinic UV hazard exposure for the skin and eye, near-UV hazard exposure for the eye, retinal blue light hazard exposure, retinal thermal hazard exposure, thermal radiation hazard for eye and skin, for LED products, UV-Lamps, lighting sources, luminaires and etc.
-
product
Total Luminous Flux Measurement System
This system enables the total luminous flux measurement of luminous intensity distribution 2 and 4 light sources based on the measurement standards of LED lightings LM-78 and LM-79 approved by IESNA (Illuminating Engineering society of North America) .
-
product
Color Tester
OCM-510 series
The OCM-510 Color Tester has an internal Czerny-Turner spectro- scope and along with providing both high-wavelength precision and high-wavelength resolution in a compact unit also employs a high-precision yet high-sensitivity line sensor in the detector to serve as a versatile spectrophotometric device for making optimal high-speed measurements.
-
product
DIFFRACTIVE DIFFUSION PLATES
LSD
Optcom Diffusion Plates Not Only Diffuse Light But Also are Available in Each Diffusion Level, Which Makes Them Ideal for Adjusting Light Quantity When Measuring Light Source Optical Characteristics. Ideal for light intensity adjustment. 5 types available depending on the degree of diffusion.