EMSYST Ltd
The company’s focus is in the field of test equipment designed for the purposes of testing electricity meters, current transformers and electrical network analysis. In addition, the company has developed a portfolio of equipment designed for testing water and heat meters.
- 359/2/971-83-50
- 359/2/971-84-19
- emsyst@emsyst.com
- “Tsarigradsko shousse” Blvd., 7th km, №133
office 304
BIC-IZOT, 1784
Bulgaria
Filter Results By:
Products
Applications
-
product
Portable Three-Phase Current Load
EE-120A-3
The Current Source is able to generate three-phase currents, synchronized with the service voltage, with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current is individually adjustable. The values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
product
Portable Three-Phase Phantom Load
EE-120A-3 + EE-500V-3
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. The generated values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
product
Three-Phase Network Analyzer
NET VISION 2010
NET VISION 2010 is a portable device designed for a quick and precise measurement of the electric values of a three-phase network. It is used by power engineers for check of AC motors, relay current protections, electricity meters, etc.
-
product
Portable Electricity Meter Testers
EE-120A-3S + EE-500V-3
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.
-
product
Portable Single-Phase Energy Standard
PEWM-3C-1
The single-phase energy standard PEWM-3C-1-1 is used for a quick check on site of all types single-phase electricity meters – for active, reactive or apparent energy, electromechanical and electronic. The voltage and the current are measured at the same time. The current can be measured directly within 10A or 100A range or with current clamp to 100A. The current clamp is electronically compensated.
-
product
Meter Test Benches
TST 3/5 UNIVERSAL
*A Three-Phase Voltage Generator EE-500 V for voltages up to 500Vac;*Five identical Modules EE-120A, each comprising three-phase current generators from 1 mA to 120A each) and Energy Standard Class 0.04;*Meter Suspension Rack with 5 positions for hanging the meter, Scanning Heads, Electronic Readers, Tariffs, Panic Button, Lamp;*PC with EE Software for control, memorizing, search and print of Reports.
-
product
CT Tester, Meter Tester, Circuit Analyzer
GOLD MINER IV
Gold Miner is the first device of its type to test the electricity meter using exact, simultaneous measurements made on all primary and all secondary phases of the circuit. Perform in-service meter testing with a combined 3-phase load, or a single-phase load. Gold Miner not only displays the Meter’s accuracy, but also the overall, true accuracy resulting from the CTs + Meter combination for your entire measurement circuit.
-
product
Portable Three-Phase Energy Standard
PEWM-3C
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
product
Portable Electricity Meter Testers
EE-120A-3S
The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.
-
product
Portable Electricity Meter Testers
EE-120A-1S
The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.
-
product
Meter Test Benches
Test Station
The meter test station allows simultaneous testing of 3, 5, 10 or 20 induction or static electricity meters. The test station could be constructed for single-phase electricity meters or for three-phase meters.