Showing results: 76 - 90 of 135 items found.
-
MI-1271M12 -
Ono Sokki
The MI-1271M12 TEDS Microphone consists of 1/2-inch Free-field electrets-type condenser microphone and preamplifier conforming to the IEC 61094-4 Type WS2F.By adopting the titanium vibrating membrane of the microphone and improving electrets performance, it realizes long-term stability and wide frequency range of 1 Hz to 20 kHz. It can be used in wide temperature range of -30℃ to +80℃.
-
LA-7000 series -
Ono Sokki
The LA-7000 series is newly designed sound level meter which operation procedure has been greatly improved. The large color LCD and touch panel enable easy and intuitive operation.
-
Ono Sokki
Ono Sokki Sound & Vibration measurement products - sound level meter, microphone & amp, accelerometer, vibration, laser doppler vibrometer, and related software.
-
LV-7000 series -
Ono Sokki
The LV-7000 series detects speed, uneven speed, distance, length of moving object or rotating object without contact. By contacting with 2 sensors, it enables to calculate difference in velocity/length between the two points in real time and output with 3,000 ppm of accuracy. The frequency response can be expanded up to 20 kHz, which achieves to understand phenomena and evaluate mechanical systems at high speed, efficiently, and accurately. It is useful for evaluation of motor control and behavior measurement, improving parts quality, and reducing loss of material.
-
VX-1100A -
Ono Sokki
VX-1100 is for a piezoelectric type accelerometer which is widely used for measuring vibration. This compact calibrator is effective for checking operation(sensitivity) sensors before measurement to acquire accurate data.Built-in sensor amplifier and display in one unit allows direct reading of the sensitivity. This calibrator excites the sensor at a frequency of 159 Hz and acceleration of 10 m/s2 rms, and the sensor outputs can be used as calibration signals for a vibration measuring system.
-
PS-1300 -
Ono Sokki
The PS-1300 3-Ch Sensor Amplifier is designed to be compact and light weight, and able to be used in combination with a tri-axial accelerometer. Each channel can also be used independently and connected with a single axis accelerometer. The PS-1300 has built-in integration function and enables to optimize the input signal to vibration data analysis devices connected.
-
CH-6130/6140 -
Ono Sokki
The CH-6130/6140 charge converter is a simplified type of charge amplifier converting charge signal to voltage.It can be connected directly to an input BNC connector of a CCLD applicable equipment such as FFT analyzer or vibration comparator, enabling direct connection of a charge output pickup without suing a box type amplifier.
-
CH-1200A -
Ono Sokki
CH-1200A is a high-performance charge amplifier to convert charge signal to voltage signal. Built-in integration function allows optimization of the signal which is input to the vibration data analyzer connected.Changing into a multi-channel amplifier is easy by connecting multiple units.
-
RH series -
Ono Sokki
High rigidity: highly accurate detection of torque fluctuation with high response. The RH series is a torque detector that can accurately detect torque fluctuations with high torsional rigidity about 4.5 times compared to the existing products.
-
FZ-2200A -
Ono Sokki
The FZ-2200A Massflow Meter is Coriolis flow meter that accurately measures the flow of fuels such as gasoline, light oil and kerosene. It is used in combination with the FM-3100 Digital Flow Meter that incorporates the FM-0321 module for the FZ series. The FZ-2200A Massflow Meter is capable of measuring continuous mass flow, making it suitable for the measurement of fuel flow during mode operation, and in-line measurement of fuel density at the same time of mass flow measurement. It can measure fuel consumption from passenger vehicles and medium trucks to large vessels. (As for small flow rate, made to order. Please make sure to check the measurement range when selecting a product.)
-
FX-1100 Series -
Ono Sokki
The FX-1100 Series Mass Burette Flow Detector takes the position of the fluid surface inside the burette as the head pressure using the differential pressure detector attached at the bottom and directly measures the flow of fluid as a mass based on changes in this pressure. It does not require calculation correction of temperature and specific gravity, and has many advantages such as high accuracy and extremely less affected by air bubbles, which enable to measure fuel consumption in the tests such as chassis dynamometer and engine bench. The 3 models are available according to the measurement range and application.
-
DF-2200 -
Ono Sokki
The DF-2200 On-Board Flow Meter is a compact on-board fuel flow meter developed for our FP series Volumetric Flow Detector*. The compact body is equipped with functions such as flow rate/temperature/pressure measurement and CAN communication required for fuel consumption measurement. Adopting the same size as our CT-6700 Engine Tachometer, it can be used by stacking two units in a limited space. In addition to 12 to 24VDC of power source, an AC adapter is available as an option, which is sufficient for not only on-board measurement but also engine bench evaluation.
-
FP-5000 Series -
Ono Sokki
In engine evaluations such as emission mode tests and transient tests for performance evaluation, the evaluation methods have been shifting from steady-state tests to transient tests. In the evaluation of fuel consumption, the requirement for evaluating the fuel consumption characteristics in transient duration has been increasing as well as the total fuel consumption for each mode. The FP-5000 series has achieved high pulse resolution and wide measurement range. It enables to detect changes in the flow rate effectively and responsively, and measure large flow rate. It can be used when the flow rate increases, such as when measuring alcohol fuel.
-
FM-3100 -
Ono Sokki
In the field of engine development, it is increasing the requirement for improving the accuracy of the measurement in the small flow rate range, and evaluating the fuel consumption characteristics in transient duration. The FM-3100 enables to meet various requirements in that field.
-
MF-015 -
Ono Sokki
If the fuel passing through a flow detector has mixing of air, the flow rate cannot be measured correctly. The MF-015 is an automatic air purging tank that uses a precision float valve. When fluid enters the flow line, the air is automatically purged to the atmosphere.