Pickering Interfaces Inc.
Pickering Interfaces designs and manufactures modular signal switching and simulation for use in electronic test and verification. We offer the largest range of switching and simulation products in the industry for PXI, LXI, PCI & USB applications. Our products are specified in test systems installed throughout the world and have a reputation for providing excellent reliability and value.
- +44 (0)1255 687900
- sales@pickeringtest.com
- Stephenson Road
Clacton on Sea
Essex, CO15 4NL
United Kingdom
Filter Results By:
Products
Applications
-
product
PXI/PXIe Power Relay Module, 8xSPDT, 5 Amp, 50-Pin SGMC Connector
40-158-004
The 40/42-158-004 is a PXI/PXIe high density power relay module with 8xSPDT switches rated at 5A. User connection is via a 50-pin SGMC male connector. The 40/42-158 range is available in 8, 16, 24 or 32 SPST configurations with or without hardware interlock. Electro-mechanical power relays are used which are suitable for switching loads up to 5A at 250VAC.
-
product
8 Slot, 3U, 350W, PXI Chassis
40-908-001
This PXI chassis includes all the features and performance required by version 2.1 of the PXI standard and supports a control interface or embedded controller and up to seven more 3U peripheral modules.
-
product
PXI High Density MUX BRIC, 32-Chan, 10-Pole
40-570-412
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI High Density MUX BRIC, 16-Chan, 20-Pole
40-570-312
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI/PXIe Power Relay Module, 5xSPST, 30 Amp
40-166-002
The 40/42-166-002 is a PXI/PXIe high density power relay module with 5xSPST switches rated at 30A. The 40/42-166 range is available with SPST, SPDT or SP4T switching configurations. It uses power relays which are suitable for switching loads up to 20A at 240VAC (SPDT & SP4T versions) or 30A at 277VAC (SPST versions).
-
product
PXI MUX 1-Bank of 80 Channel 1-Pole
40-615-021-1/80/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
PXI BRIC4 FIBO Matrix Dual 40x4 3pin brkout
40-592A-002
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
PXI Single 55x8 Matrix 1-Pole Switching
40-538-021
The 40-538 ultra high density matrix module is configured as a Single 55x8 reed relay matrix with 1-pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering >10e8 operations to give maximum switching confidence with long life and stable contact resistance.
-
product
LXI High Voltage Switching - 40xSPST Plugin Module
65-233-901
The 65-233-901 plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
PXI Strain Gauge Simulator Module 2-Channel, 1.5K
40-265-402
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 2-channel, 1.5Ω) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
product
PXI/PXIe High Density Precision Resistor Module, 9-Channel
40-297A-035
The 40-297A-035 (PXI) and the 42-297A-035 (PXIe) are 9-channel programmable resistors with a range of 2 Ω to 102 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
PXI Dual 16x8 Matrix, 1 Pole Switching
40-532-021
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
product
PXI/PXIe 15W Programmable Resistor Module
42-254-030
The 40-254-030 (PXI) and 42-254-030 (PXIe) are programmable resistor modules with 1 channel which can be set between 2Ω and 6.97kΩ with 0.125Ω resolution The 40-254 range provides a simple solution for applications requiring up to 15W of power handling per channel.
-
product
PXI 8-slot BRIC Power Multiplexer, 20-Channel, 12-Pole (7 Sub-cards)
40-571A-305
The 40-571A-305 is a 20-channel, 12-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.