Pickering Interfaces Inc.
Pickering Interfaces designs and manufactures modular signal switching and simulation for use in electronic test and verification. We offer the largest range of switching and simulation products in the industry for PXI, LXI, PCI & USB applications. Our products are specified in test systems installed throughout the world and have a reputation for providing excellent reliability and value.
- +44 (0)1255 687900
- sales@pickeringtest.com
- Stephenson Road
Clacton on Sea
Essex, CO15 4NL
United Kingdom
Filter Results By:
Products
Applications
-
product
PXI 5A Power MUX, 8-Bank, 5-Channel
40-651-004
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
PXI/PXIe Power Relay Module, 12xSPDT, 16 A, With Interlock
40-161A-101-HI
The 40/42-161A-101-HI is a PXI/PXIe 12xSPDT power relay module with optional hardware interlock. It is part of a range of high density power switching solutions with a choice of SPST, and SPDT relay configurations with or without hardware interlock.
-
product
160 Pin DIN Connector & Cable Accessories
The 160 Pin DIN connector is used on switching products to provide a high density 2A connector solution. If you would like to develop your own cabling solutions, we offer mating connectors and connector hoods that allow you to create either your own cable based solutions, or a PCB header solution. Connector Blocks directly terminate the module connector and convert the connection to arrays of screw terminal blocks, or you can select to use a remote DIN rail mounted breakout to terminate the cables at the end of a cable assembly. You can also try our Cable Design Tool to graphically design a customized cable assembly.
-
product
PXI Twelve 2:1 High Voltage Power MUX
40-331-006
The Pickering Interfaces 40-331/332 High Voltage Power Multiplexer and Matrix Modules are suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. The 40-331 is available as a single 24:1, dual 12:1, quad 6:1, hex 4:1, octal 3:1 or twelve 2:1 multiplexer, and the 40-332 is available in 12x2 or 6x4 matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
product
Cable Assembly 68-Pin Micro-D Female to Unterminated, Cut Ends, 2m, Screwlocks
A068SFR-C-6B200
The 68-Pin Connector to Unterminated Cable Assy is constructed from 7/36 (28AWG) twisted pair wires with polypropylene insulation. The wires are colour coded to match the connector pin designation. The connector can be secured to the product by 2-56 UNC Screwlocks.
-
product
PXI 5W Programmable Resistor Module, 4-Channel, 1Ω to 122Ω
40-252-012
The 40-252-012 is a programmable resistor module with 4 channels which can be set between 1Ω and 122Ω with 0.5Ω resolution The 40-252 range provides a simple solution for applications requiring up to 5W of power handling per channel. The 40-252 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems. Each channel is able to simulate short or open circuit conditions that can be experienced in a system caused by faulty wiring or sensors.
-
product
PXI High Density MUX BRIC, 12-Chan, 80-Pole
40-570-116
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI 16 Bank 5 Channel 1 Pole Multiplexer
40-616-021-16/5/1
The 40-616 16-Bank, 5-Channel, 1-Pole Multiplexer Module forms part of the System 40 PXI Programmable Switching system. The Module consists of 16 electrically isolated banks of multiplexers controlled by a PXI/ PCI interface. Each bank is a 1 to 5 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously. The module is suitable for cascading in applications that require large multiplexer systems, it is also suitable for test systems that require the switching of a large number of signals in parallel.
-
product
Single 24x4 1-Pole High-Density PXI Matrix Module
40-520-402
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
product
Cable Assembly, 50-Pin D-Type, Male to Male, 0.5m HV, Exit Away From Pin 1
40-970-050-0.5m-MM-HV
50-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24 AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assemblies can be secured to the mating part by a screwlock. The 50-Pin Female connector options of this product can be directly mated to a corresponding Pickering Interfaces switching product.
-
product
PXI 2A Multiplexer, 1-Bank, 4-Channel 32-Pole
40-614-020
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
PXI Strain Gauge Simulator Module 4-Channel, 2k
40-265-304
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 4-channel, 2kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
product
MS-M 3-Pin RF Cable Assembly, Female to Unterminated, 0.5m, RG178 Cable
40-979A-503-0.5m-FU
This 0.5m long MS-M RF 3-Pin cable assembly is constructed from RG178 Silver Plated Copper Clad Steel Wire with FEP insulation and an attenuation of 102dB/100m at 500MHz. Screwlocks are provided to secure the MS-M connector to the associated product.
-
product
Diagnostic Test Tools For Switching Systems
You know that verification and diagnosis of complex switching operation in a test system has always been an issue. Two of our latest offerings in diagnostic test tools provide a quick and simple way of finding relay failures within LXI, PCI and PXI switch systems.
-
product
High-Density PXI Multiplexer Switch Modules
This range of High-Density Multiplexer Switch Modules provides a compact array of MUX solutions with differing combinations of channel counts and poles. Most of our high-density solutions include isolation relays that allow the MUX to be disconnected from the single input/output port, enabling the convenient interconnection of other channels.