Georg Fischer Signet

Committed to product excellence, Georg Fischer Signet continues its pursuit of quality through innovative, leading-edge technology in flow control and measurement. Award winning design, ISO 9001 certification and comprehensive technical and customer support are just a few reasons why Signet products are leading the industry well into the new millennium.

  • 714-731-8800
  • 714 731 62 01
  • signet.ps@georgfischer.com
  • 9271 Jeronimo Road
    Irvine, CA 92618
    United States

Filter Results By:

Products

Applications

Showing results: 31 - 40 of 40 items found.

  • Variable Area Flow Meter

    SK Series - Georg Fischer Signet

    The plastic variable area flow meters in the SK series from GF Piping Systems are radially-installed dismountable meters for measuring the rate of flow in industrial pipework applications.

  • Multi-Parameter Controller

    8900 - Georg Fischer Signet

    The Signet 8900 Multi-Parameter Controller takes the concept of modularity to the extreme. Each 8900 Controller is field-commissioned with the users-specified combination of inputs, outputs, and relays using simple-to-install modular boards into the base unit. Configure the system by selecting either two, four, or six input channels which accepts any of the Signet sensors listed below, and/or other manufacturer's sensors via a 4 to 20 mA signal converter (Signet Model 8058). To complete your unit, choose a power module with universal AC line voltage or 12 to 24 VDC.

  • Ultrasonic Flowsensor

    ULTRAFLOW U3000 / U4000 - Georg Fischer Signet

    The Ultraflow brings simplicity to the non-invasive measurement of liquid flow, offering the user quick and accurate flow measurement with its easy to follow menu and simple set up. Dry servicing, providing minimum downtime and maximum availability, even in a continuously running system. Compact, rugged and reliable, the Ultraflo has been designed to provide sustained performance in industrial environments.

  • Guided Wave Radar Level Transmitter

    2291 - Georg Fischer Signet

    The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids, pulps and solids. The 2291 level gauge operates based on the well-known TDR (Time Domain Reflectometry) principle. Micropulses are sent along a probe guide at the speed of light. As soon as the impulse reaches the surface of the medium, it is reflected back to the electronic module. Level distance is directly proportional to the flight time of the impulse.

  • Ultrasonic Gap Switch

    2284 - Georg Fischer Signet

    The Ultrasonic Gap Switch consists of Polyphenylene Sulphide (PPS) and is high corrosion resistant in most liquids. The gap switch is designed for high or low level alarm in different tank applications as well as pump control. However, if there is a liquid present, the signal will be transmitted across the gap and the integral electronics will switch the output circuitry to signal the presence of a liquid.

  • Magmeter Flow Sensor

    2551 - Georg Fischer Signet

    The Signet 2551 Magmeter is an insertion-style magnetic flow sensor that features no moving parts. The patented* sensor design is available in corrosion-resistant materials to provide long-term reliability with minimal maintenance costs. Material options include PP with stainless steel, PVDF with Hastelloy-C, or PVDF with Titanium. Utilizing the comprehensive line of Signet installation fittings, sensor alignment and insertion depth is automatic. These versatile, simple-to-install sensors deliver accurate flow measurement over a wide dynamic range in pipe sizes ranging from DN15 to DN900 ( to 36 in.), satisfying the requirements of many diverse applications.

  • Flow Wet-Tap Valve

    3519 - Georg Fischer Signet

    The Signet 3519 Flow Wet-Tap Valve serves as a unique interface between the installation fitting and the wet-tap style Signet 515 or 2536 Rotor-X Flow Sensor. It provides a fast method of removing the sensor from the pipe under specified operating pressures. The PVC and stainless steel design of Wet-Tap makes it resistant to corrosion and chemical attack by acids, alkalis, salt, and a number of other harsh chemicals.

  • Stainless Steel High Performance Flow Sensor

    2540 - Georg Fischer Signet

    The Signet 2540 Paddlewheel Flow Sensor offers field-replaceable electronics and transient voltage suppression (TVS) to provide greater immunity to large voltage disturbances (i.e. lightning) sometimes encountered in field wiring. Sensors can be installed in DN40 to DN600 (1 to 24 in.) pipes using the 1 inch NPT or ISO 7/1-R 1.5 threaded process connection. The sensors are also offered in a hot-tap configuration with a bleed valve service without process shutdown in pipes up to DN900 (36 in.). Both styles of sensors must be used in full pipes and can be used in low pressure systems.

  • Conductivity-Resistivity Sensor Electronics and Integral System with PVDF Sensor

    2850 - Georg Fischer Signet

    The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet Conductivity/Resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, 10.0 or 20.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 400,000 S or a resistivity range of 18.2 M to 10 k.

  • Metal Magmeter Flow Sensor

    2552 - Georg Fischer Signet

    The Signet 2552 Metal Magmeter features all-stainless steel construction. The PVDF nosepiece and FPM O-rings are the only other wetted materials. The 2552 installs quickly into standard ISO 7-R 1 or ISO 7-R 1 (1 in. to 1 in. NPT) pipe outlets, and is adjustable to fit pipes from DN50 to DN2550 (2 to 102 in.). Two sensor lengths allow maximum flexibility to accommodate a variety of hardware configurations, including ball valves for hot-tap installations.

Get Help