Applied Image, Inc.
APPLIED IMAGE Inc. is a world leader in the design and manufacture of precision-imaged optical components intended for a wide range of applications and industries that require NIST-traceable standards and/or precision-imaged components to test, calibrate, align, control or measure their optical or photonics systems. In addition to its large catalog of standard products, APPLIED IMAGE specializes in designing and manufacturing custom components, imaged to the strictest tolerances. Its mission is to provide the highest-quality products and customer service to consistently meet and exceed the expectations of its customers such as NASA (Mars Rover) and Goddard (International Space Station).
- (585) 482-0300
- (585) 288-5989
- 1653 East Main Street
Rochester, NY 14609
United States
Filter Results By:
Products
Applications
-
product
Standard Step Tablets, Gray Scales & Density Reference Charts
Standard Step Tablets, Gray Scales & Density Reference Charts are available in a wide variety of patterns, designs and sizes to fit a multitude of today’s application needs. Our gray scales and density patches are measured on a variety of NIST traceable instrumentation, including some of the most sophisticated microdensitometers available to the industry. They are imaged on either Photo Paper (RM) or Film (TM) to function for reflective or transmissive applications.
-
product
Optical Apertures
The APPLIED IMAGE Optical Aperture reticles are available in sizes from 10μm (0.01mm) to 1,000μm (1.0mm) center openings (noted by -10, -25, -30 etc.), on either Chrome on Glass or Chrome on Opal material, with an overall size of 25.4mm (1.0 inch) diameter.
-
product
Optical Slits
The APPLIED IMAGE Optical Slit reticles are available in sizes from 10μm (0.01mm) to 1,000μm (1.0mm) widths, on either Chrome on Glass or Chrome on Opal material, with an overall size of 25.4mm (1.0 inch) diameter.
-
product
PhotoMASK Services
For years APPLIED IMAGE has been serving customers who work with semiconductors, displays, PCB, MEMS, along with college professors, researchers, and students with Photomask making solutions tailored specifically to each customer’s needs. Working with a dedicated sales engineer means that you will have all of your questions answered.
-
product
Custom Solutions
We employ a collaborative process that provides our customers with the perfect component. This step-by-step process guides our customers through the creation of totally customized products. Our expert sales engineers take you from conceptual design to prototype, and then final part production, making the process as easy as possible.
-
product
USAF Targets
These targets conform to MIL-STD-150A. Frequencies change by the 6th root of 2. This target is also available in custom sizes and contrasts. This test target meets requirements as specified in MIL-STD-150A for resolving power tests. The target consists of a series of Elements having two sets of lines at right angles. Each set of lines consists of three lines separated by spaces equal to the line width. Each bar has a length to width ratio of 5:1. (Line width is equal to one half of line pitch, which is the inverse of line frequency.) Elements are arranged in groups of six each and Groups are arranged in pairs. Even numbered Groups occupy the left side and bottom right corner and contain a square feature having and edge length equal to the line length of Element 2 in that group. Odd numbered Groups occupy the top right corner and side. Groups and Elements are labeled and differentiated by numbering adjacent to their features. Frequencies in cycles/mm (c/mm) increase between each Element by the sixth root of two (approximately 12.25% per step). The general formula for the line frequency of any target Element can be expressed as 2Group+(Element-1)/6.
-
product
Test Targets & Charts
APPLIED IMAGE is a world leader in the field of IMAGE EVALUATION Test Targets and Test Charts. Some of the specialized test charts include camera image evaluation ISO, NIST, ANSI, and MIL standard image evaluation applications; photonic and optophotonic applications; test charts for copiers and scanner; DATAcapture and BARcode Scanning testing; Security & Identification Image Capture; and all other type of imaging industries that require quality evaluation of thier image capture systems.
-
product
ISO Test Charts
ISO has been the governing body for Image Quality Testing all over the world. To that end, APPLIED IMAGE is proud to be a participant in assuring that the industry has products that meet or exceed the requirements of ISO. Since ISO covers many levels, we provide test patterns of various types that can be used for Image Capture and Evaluation of Optical and Imaging systems of all types.
-
product
NBS Targets
NBS Targets by Applied Image - NBS-1952 Resolution Test Chart, ANSI/ISEA Z87.1-2020 Test Resolution Standard
-
product
ACCUplace BullsEye /Recognition Grid
AP-B Series
A unique concept in imaging calibration technology, The ACCUplace Bulls Eye / Recognition Grid allows the end user to calibrate magnification at multiple power levels, as well as test the system’s ability to recognize and locate distinctive shapes within shapes by focusing on the concentric circles.Each Bulls Eye / Recognition Grid target has individual patterns consisting of 5 concentric circles with 0.50mm line width and 0.50mm spacing between circles (10mm Pitch) with a 0.100mm center dot. In addition, each row and column is labeled with X & Y coordinates. The AP-B series is offered on four standard substrates; Chrome on Glass (CG) Opal (OP) Photopaper (RM) and Film (TM).
-
product
ACCUplace Dot Distortion Target
AP-DD Series
All machine vision lenses will show some type of distortion. Minimizing or correcting that distortion is crucial in most applications. The ACCUplace Dot Distortion target is designed to detect the presence of both barrel/pincushion distortion as well as alignment distortion that causes the keystone effect. The precise amount of distortion is determined from an array of precisely placed dots in a regular array. The results can be used to correct for any distortion that occurs within the optical system. The AP-DD is offered on three standard substrates; Chrome on Glass (CG) Opal (OP) and Photo Paper (RM).
-
product
O.E.M. Specific Test Charts
O.E.M. Specific Test Charts by Applied Image - IMATEST SFRPlus Chart, ISA ColorGauge Targets, ISA Device Level Target, ISA Object-Level Target Family, ISA Spatial Frequency Response Target
-
product
O.E.M. Optical Standards
O.E.M. Optical Standards by Applied Image - Boston Scientific Checkerboard Array, Cognex Glass Calibration Plate Set
-
product
EIA Test Charts
EIA Test Charts by Applied Image - EIA Halftone Gray Scale Chart, EIA Video Resolution Pattern
-
product
Siemens/RIT/Other Targets
Siemens/RIT/Other Targets by Applied Image - RIT Alphanumeric Chart, Siemens/Star Sector Target, Resolution 2-Cycle Long Test Chart, Sayce Target, Resolution Linear Test Chart, Ultra-High Resolution Target, Digital/Electronic Pixel Target