PXI Medium Density Switch Matrix Modules
Pickering's range of medium density switch matrix modules is a cost-effective solution for applications that require mid-range matrices in the PXI format. Selected modules are supported by our Diagnostic Test Tools, Built-In-Relay-Self-Test (BIRST) and eBIRST Switching System Test Tools, these tools provide a quick and simple way of finding relay failures within LXI, PCI and PXI switch systems.
- PXI Matrix Switch Modules
- PXI Medium Density Switch Matrix Modules
- Low-Density PXI Switch Matrix Modules
- High-Voltage PXI Switching Matrix Modules
- High-Power PXI Switch Matrix Modules
- High-Density PXI Switch Matrix Modules
-
product
PXI Single 44 x 4 Matrix 1 Pole Screened
40-523-021-S
40-523-021-S - Pickering Interfaces Inc.
The 40-523 module is configured as a 44x4 high density matrix with available reedrelay formats of 1-pole, 2-pole and 1-pole screened. The screened version is suitablefor switching signals up to 50MHz. Model 40-524 is a similar matrix, available insingle pole 46x4 format. Typical applications include signal routing in FunctionalATE and data acquisition systems. These PXI matrix cards are constructed using highreliability Ruthenium Electro-Plated Reed Relays, offering >10e8 operations togive maximum switching confidence with long life and stable contact resistance.
-
product
PXI High-Density Matrix Module, 16x8, 1-Pole, 2 A 60 W, With Interlock
40-529B-001-HI
40-529B-001-HI - Pickering Interfaces Inc.
The 40-529B-001-HI is a 128 crosspoint PXI matrix with single pole switching and includes hardware intrlock. The matrix is configured as 16x8 using electro-mechanical relays with 2 A current handling.
-
product
PXI 16x4 Signal Insertion and Monitor Matrix
40-525A-002
40-525A-002 - Pickering Interfaces Inc.
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also available in a 34x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system.
-
product
PXI High Density Matrix Module, 32x4, 1-Pole, 2A, 60W
40-528B-001
40-528B-001 - Pickering Interfaces Inc.
PThe 40-528B is a 128 crosspoint PXI matrix with single pole switching and a configuration of 32x4 using electromechanical relays with 2 A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems.
-
product
PXI High-Density Matrix Module, 16x8, 1-Pole, 2 A 60 W
40-529B-001
40-529B-001 - Pickering Interfaces Inc.
The 40-529B-001 is a 128 crosspoint PXI matrix with single pole switching. The matrix is configured as 16x8 using electro-mechanical relays with 2 A current handling.
-
product
PXI 64x2 Matrix Module, 1-Pole, 2A, 60W
40-527A-001
40-527A-001 - Pickering Interfaces Inc.
The 40-527A, is a PXI single-pole 64x2 matrix and is part of a range of matrices supporting 128 crosspoints. All models use gold-plated contact electromechanical relays.
-
product
PXI 34x4 Signal Insertion and Monitor Matrix
40-525A-001
40-525A-001 - Pickering Interfaces Inc.
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also availablein a 16x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system. Each pass thru connection from LX to X can be open or closed to allow the programmatic disconnection of the signal to check the response of the UUT. The matrix can be used to connect test equipment, such as a DMM or scope, to monitor the pass thru signals via Y connections while the LY connections can be used to insert a fault condition or insert external signals. When external signals are injected the LX connections can be opened and the LY connections closed.
-
product
PXI 32x4 2-Pole 2A Matrix Module
40-519B-002
40-519B-002 - Pickering Interfaces Inc.
The 40-519B-002 is a 32x4 2-pole medium density matrix module and is designed for switching medium voltage/power signals in test applications where reed relays do not have sufficient rating. They are also suitable for telecoms applications where send and return signals need to be switched simultaneously.
-
product
PXI 16x8 2-Pole 2A Matrix
40-518A-002
40-518A-002 - Pickering Interfaces Inc.
The 40-518A-002 is a 16x8 2-pole medium density matrix module and is designed for switching medium voltage/power signals in test applications where reed relays do not have sufficient rating. They are also suitable for telecoms applications where send and return signals need to be switched simultaneously.
-
product
PXI 42x4 Matrix Module, 1-pole 2A 60W
40-505-001
40-505-001 - Pickering Interfaces Inc.
This range of medium density PXI matrix modules (40-505 thru 509) are able to switch up to 2 Amps or 300VDC/250VAC and come in42x4, 32x6, 25x8, 18x12 and 14x16 options. The modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 160-pin DIN 41612, 78-pin D-type or 50-pin D-Type connector that is fully supported by the wide range of our cable and connector accessories.
-
product
PXI 32x6 Matrix Module, 1-pole 2A 60W
40-506-001
40-506-001 - Pickering Interfaces Inc.
The 40-505/506/507/508/509 are a range of medium density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. They are constructed using high quality electro-mechanical relays for high switching confidence.
-
product
PXI 25x8 Matrix Module, 1-pole 2A 60W
40-507-001
40-507-001 - Pickering Interfaces Inc.
The 40-505/506/507/508/509 are a range of medium density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. They are constructed using high quality electro-mechanical relays for high switching confidence.
-
product
PXI 18x12 Matrix Module, 1-pole 2A 60W
40-508-001
40-508-001 - Pickering Interfaces Inc.
The 40-505/506/507/508/509 are a range of medium density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. They are constructed using high quality electro-mechanical relays for high switching confidence.
-
product
PXI Single 44x4 Matrix, 1-Pole Switching
40-523-021
40-523-021 - Pickering Interfaces Inc.
A 44x4 medium density matrix - product range comes with available reedrelay formats of 1-pole, 2-pole and 1-pole screened. The screened version is suitablefor switching signals up to 50MHz. These PXI matrix cards are constructed using highreliability ruthenium electro-plated reed relays, offering >10e8 operations togive maximum switching confidence with long life and stable contact resistance.
-
product
PXI 14x16 Matrix Module, 1-pole 2A 60W
40-509-001
40-509-001 - Pickering Interfaces Inc.
The 40-505/506/507/508/509 are a range of medium density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. They are constructed using high quality electro-mechanical relays for high switching confidence.
-
product
PXI Single 24x8 Matrix, 1 Pole Switching
40-521-021
40-521-021 - Pickering Interfaces Inc.
An ultra high density matrix module is configured as a 24x8, this range is availablein a choice of reed relay formats: 1-pole (shown here), 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability RutheniumElectro-Plated Reed Relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance.
-
product
PXI Dual 12x8 Matrix, 1 Pole Switching
40-522-021
40-522-021 - Pickering Interfaces Inc.
Medium density PXI dual 12x8, 1-pole matrix - it is also available inreed relayformats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable forswitching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems.The two banks may be used for operating a 4-wire measurement system (bank-1 for source,bank-2 for measure). Larger matrices may be constructed by daisy chaining the commonsignals from multiple PXI Modules.
-
product
PXI Single 46x4 Matrix, 1 Pole Switching
40-524-021
40-524-021 - Pickering Interfaces Inc.
Medium density PXI dual 46x4, 1-pole matrix - it is also available inreed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
product
PXI Single 44x4 Matrix, 2 Pole Switching
40-523-022
40-523-022 - Pickering Interfaces Inc.
Medium density PXI dual 44x4, 2-pole matrix - it is also available in reed relay formats of 1-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
product
PXI Dual 12x8 Matrix, 2 Pole Switching
40-522-022
40-522-022 - Pickering Interfaces Inc.
Medium density PXI dual 12x8, 2-pole matrix - it is also available in reed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
product
PXI Single 24x8 Matrix, 2 Pole Switching
40-521-022
40-521-022 - Pickering Interfaces Inc.
Typical applications for this high density matrix include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability rutheniumelectro-plated reed relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, 7 PXI modules will form a 168x8 Matrix, a total of 1344 crosspoints in a 7-slot PXI Chassis. All 40-521 series modules are fitted with reed relays (ruthenium sputtered type), these offer very long life with good low level switching performance and excellent contact resistance stability.Spare Reed Relays are built onto the circuit board to facilitate easy maintenance with minimum downtime.