Test Targets & Charts
APPLIED IMAGE is a world leader in the field of IMAGE EVALUATION Test Targets and Test Charts. Some of the specialized test charts include camera image evaluation ISO, NIST, ANSI, and MIL standard image evaluation applications; photonic and optophotonic applications; test charts for copiers and scanner; DATAcapture and BARcode Scanning testing; Security & Identification Image Capture; and all other type of imaging industries that require quality evaluation of thier image capture systems.
-
product
USAF Targets
These targets conform to MIL-STD-150A. Frequencies change by the 6th root of 2. This target is also available in custom sizes and contrasts. This test target meets requirements as specified in MIL-STD-150A for resolving power tests. The target consists of a series of Elements having two sets of lines at right angles. Each set of lines consists of three lines separated by spaces equal to the line width. Each bar has a length to width ratio of 5:1. (Line width is equal to one half of line pitch, which is the inverse of line frequency.) Elements are arranged in groups of six each and Groups are arranged in pairs. Even numbered Groups occupy the left side and bottom right corner and contain a square feature having and edge length equal to the line length of Element 2 in that group. Odd numbered Groups occupy the top right corner and side. Groups and Elements are labeled and differentiated by numbering adjacent to their features. Frequencies in cycles/mm (c/mm) increase between each Element by the sixth root of two (approximately 12.25% per step). The general formula for the line frequency of any target Element can be expressed as 2Group+(Element-1)/6.
-
product
ISO Test Charts
ISO has been the governing body for Image Quality Testing all over the world. To that end, APPLIED IMAGE is proud to be a participant in assuring that the industry has products that meet or exceed the requirements of ISO. Since ISO covers many levels, we provide test patterns of various types that can be used for Image Capture and Evaluation of Optical and Imaging systems of all types.
-
product
FBI / MITRE Test Charts & Kits
FBI / MITRE Test Charts & Kits by Applied Image - FBI SIQT Scanner Test Chart, Individual Personal Identity Verification Test Charts for Single Fingerprint Capture Devices, Personal Identity Verification Kits for Single Fingerprint Devices
-
product
AIIM Test Charts (Scanner/Microfilm/Digital/ Copier)
AIIM Test Charts (Scanner/Microfilm/Digital/ Copier) by Applied Image - Motion-Rotary Target, Planetary-Static Target, Small Area Target/AIIM MS-303-1980, Small Scanner Resolution Target , Copier Test Array, Rotary Test Target/AIIM X113, Film Strip Target, Eastman Kodak Copier/Scanner Digital Test Target, Small Color MTF Target
-
product
IEEE Test Charts (Video /Cine)
IEEE Test Charts (Video /Cine) by Applied Image - IEEE Video Resolution Chart, Picture Height Test Chart, Microsoft WebCam Image Quality Test, OTTO-2 Otto Nemenz Cine Lens Calibration Reticle
-
product
NBS Targets
NBS Targets by Applied Image - NBS-1952 Resolution Test Chart, ANSI/ISEA Z87.1-2020 Test Resolution Standard
-
product
Siemens/RIT/Other Targets
Siemens/RIT/Other Targets by Applied Image - RIT Alphanumeric Chart, Siemens/Star Sector Target, Resolution 2-Cycle Long Test Chart, Sayce Target, Resolution Linear Test Chart, Ultra-High Resolution Target, Digital/Electronic Pixel Target
-
product
EIA Test Charts
EIA Test Charts by Applied Image - EIA Halftone Gray Scale Chart, EIA Video Resolution Pattern
-
product
O.E.M. Specific Test Charts
O.E.M. Specific Test Charts by Applied Image - IMATEST SFRPlus Chart, ISA ColorGauge Targets, ISA Device Level Target, ISA Object-Level Target Family, ISA Spatial Frequency Response Target
-
product
USAF Targets
These targets conform to MIL-STD-150A. Frequencies change by the 6th root of 2. This target is also available in custom sizes and contrasts. This test target meets requirements as specified in MIL-STD-150A for resolving power tests. The target consists of a series of Elements having two sets of lines at right angles. Each set of lines consists of three lines separated by spaces equal to the line width. Each bar has a length to width ratio of 5:1. (Line width is equal to one half of line pitch, which is the inverse of line frequency.) Elements are arranged in groups of six each and Groups are arranged in pairs. Even numbered Groups occupy the left side and bottom right corner and contain a square feature having and edge length equal to the line length of Element 2 in that group. Odd numbered Groups occupy the top right corner and side. Groups and Elements are labeled and differentiated by numbering adjacent to their features. Frequencies in cycles/mm (c/mm) increase between each Element by the sixth root of two (approximately 12.25% per step). The general formula for the line frequency of any target Element can be expressed as 2Group+(Element-1)/6.
-
product
ISO Test Charts
ISO has been the governing body for Image Quality Testing all over the world. To that end, APPLIED IMAGE is proud to be a participant in assuring that the industry has products that meet or exceed the requirements of ISO. Since ISO covers many levels, we provide test patterns of various types that can be used for Image Capture and Evaluation of Optical and Imaging systems of all types.
-
product
FBI / MITRE Test Charts & Kits
FBI / MITRE Test Charts & Kits by Applied Image - FBI SIQT Scanner Test Chart, Individual Personal Identity Verification Test Charts for Single Fingerprint Capture Devices, Personal Identity Verification Kits for Single Fingerprint Devices
-
product
AIIM Test Charts (Scanner/Microfilm/Digital/ Copier)
AIIM Test Charts (Scanner/Microfilm/Digital/ Copier) by Applied Image - Motion-Rotary Target, Planetary-Static Target, Small Area Target/AIIM MS-303-1980, Small Scanner Resolution Target , Copier Test Array, Rotary Test Target/AIIM X113, Film Strip Target, Eastman Kodak Copier/Scanner Digital Test Target, Small Color MTF Target
-
product
IEEE Test Charts (Video /Cine)
IEEE Test Charts (Video /Cine) by Applied Image - IEEE Video Resolution Chart, Picture Height Test Chart, Microsoft WebCam Image Quality Test, OTTO-2 Otto Nemenz Cine Lens Calibration Reticle
-
product
NBS Targets
NBS Targets by Applied Image - NBS-1952 Resolution Test Chart, ANSI/ISEA Z87.1-2020 Test Resolution Standard
-
product
Siemens/RIT/Other Targets
Siemens/RIT/Other Targets by Applied Image - RIT Alphanumeric Chart, Siemens/Star Sector Target, Resolution 2-Cycle Long Test Chart, Sayce Target, Resolution Linear Test Chart, Ultra-High Resolution Target, Digital/Electronic Pixel Target
-
product
EIA Test Charts
EIA Test Charts by Applied Image - EIA Halftone Gray Scale Chart, EIA Video Resolution Pattern
-
product
O.E.M. Specific Test Charts
O.E.M. Specific Test Charts by Applied Image - IMATEST SFRPlus Chart, ISA ColorGauge Targets, ISA Device Level Target, ISA Object-Level Target Family, ISA Spatial Frequency Response Target
-
product
Custom Test Targets & Charts
Our customers in industries that require camera or scanner image evaluation certainly know the challenges that come from finding the perfect target for a specific system and measurement. Thankfully, we at APPLIED IMAGE know these challenges just as well. The ability to freely customize a target has proved important for our customers to get the image evaluation tools they need. Our sales engineers are experts in different types of targets and specifications that will give you the best results for your project, and will guide you through the process from start to finish.