Showing results: 16 - 28 of 28 items found.
-
PCE Instruments
A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.
-
PCE Instruments
A radiation detector is a device for measuring nuclear, electromagnetic or light radiation. A nuclear radiation detector identifies nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a geiger counter, a nuclear radiation detector consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or nuclear radiation detector.
-
ORTEC
Gamma spectroscopy is the science (or art) of identification and/or quantification of radionuclides by analysis of the gamma-ray energy spectrum produced in a gamma-ray spectrometer. It is a widely used technique, well illustrated by the following list of examples:ICS Integrated Cryocooling System for ORTEC Radiation DetectorsEnvironmental Radioactivity MonitoringHealth Physics Personnel MonitoringReactor Corrosion MonitoringNuclear Materials Safeguards and Homeland SecurityForensics and Nuclear ForensicsMaterials TestingGeology and MinerologyNuclear Medicine and RadiophamaceuticalsIndustrial Process Monitoring
-
Pixie-16 -
XIA LLC
The Pixie-16 is a data acquisition system for nuclear physics and other applications requiring coincident radiation detection with large number of channels.
-
Solar Light Company Inc.
Solar Light Company, LLC is the world’s leading manufacturer of premium Atmospheric Instrumentation Products, including the innovative Microtops II® portable Sunphotometers and Ozonometers, the field-proven 501-Series Radiometers and Biometers for permanent outdoor installations, and the pioneering Model 511 UV Warning Signal® device. These precision instruments are heavily relied upon by the most prestigious meteorological observatories, weather stations, and research agencies in the world including NASA, the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA,) the Natural Resource Ecology Laboratory (NREL,) and countless others.
-
DDC Connectivity Power Controls
DDC's radiation-hardened, hybrid, Nuclear Event Detectors (NED) sense ionizing radiation pulses generated by a nuclear event, such as the detonation of a nuclear weapon, and rapidly switches its output from the normal high state to a low state with a propagation delay time of less than 20ns. The active low Nuclear Event Detection signal (NED) is used to initiate a wide variety of circumvention functions, thus preventing upset and burnout of electronic components. The NED output is also used to initiate both hardware and software recovery. This high-speed, 14-pin hybrid detector is used in electronic systems as a general-purpose circumvention device to protect memory, stop data processing, and drive power supply switches as well as signal clamps.
-
2740 Family -
CAEN S.p.A.
The 2740 Digitizer is a 64-channel digital signal processor for radiation detectors available in VME64 (V2740), VME64X (VX2740), and Desktop (DT2740) form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others. The 2740 can perform pulse height measurements (PHA), constant fraction timing (CFD), charge integration (QDC) and pulse shape discrimination (PSD) independently for each of the 64 channels.
-
VX2745 -
CAEN S.p.A.
The VX2745 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.
-
2745 Family -
CAEN S.p.A.
The 2745 Digitizer is a 64-channel digital signal processor for radiation detectors available in VME64 (V2745), VME64X (VX2745), and Desktop (DT2745) form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others. The 2745 can perform pulse height measurements (PHA), constant fraction timing (CFD), charge integration (QDC) and pulse shape discrimination (PSD) independently for each of the 64 channels.
-
CAEN S.p.A.
CAEN SyS is the new Systems & Spectroscopy Division of CAEN Spa. Such Division relies upon an extremely strong foundational knowledge of nuclear measurement instrumentation in developing Radiation Measurements Systems and Spectroscopy Solutions. These systems and solutions are perfectly suited to operations involving Nuclear Fuel Facilities, Nuclear Power Plants, Measurements Laboratories, and Security Applications.
-
V2740 -
CAEN S.p.A.
The V2740 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64 form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.
-
V2745 -
CAEN S.p.A.
The V2745 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.
-
VX2740 -
CAEN S.p.A.
The VX2740 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.