Filter Results By:

Products

Applications

Manufacturers

Optical

Of or related to vision, light and/or optics.

See Also: Optic


Showing results: 2776 - 2790 of 3061 items found.

  • 4-in-1 AOI Solution

    Ultra Dimension™ Series - Orbotech Ltd.

    ltra Dimension™ Automated Optical Inspection (AOI) Series for PCB production. Designed to meet the rigorous demands of advanced PCB manufacturing processes, the innovative Ultra Dimension is the first AOI solution to integrate four leading solutions - pattern inspection, laser via inspection, Remote Multi-Image Verification and 2D metrology - into a single system. This solution enables manufacturers to increase quality and yield as well as dramatically reduce their overall total cost of ownership (TCO), signifying a revolution in the AOI room workflow.

  • Multiparameter Water Quality Meter

    ProDSS - YSI Incorporated

    Handheld multiparameter instrument with multiple cable options. The YSI ProDSS (digital sampling system) handheld multiparameter meter provides extreme flexibility with two main cable options. Choose between the fully loaded 4-port cable assembly outfitted with any four DSS sensors (with depth or no depth) or the ODO/CT probe and cable - where you get accurate DO measurements every time with an optical dissolved oxygen sensor with an inline conductivity sensor, allowing for real-time salinity compensation.

  • NED-LMD Near-Eye Display Measurement Systems

    NED-LMD WG Series - Gamma Scientific Inc.

    Gamma Scientific is introducing the NED-LMD Waveguide Tester as the world’s first specialized near-eye display measurement system that mimics human visual perception for fast, accurate and repeatable characterization of next generation optical waveguide-based Augmented/Mixed Reality displays and display components (light engine, waveguide, etc.). This comprehensive offering features a ‘robotic eye’ to help device manufacturers predict how the human eye would perceive their AR/MR displays, quantifying end user experience mapping the entire display field of view.

  • Visual Fault Locator

    HW-205 - Shanghai Fibretool Technology Co.,Ltd.

    The HW-205 is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in an optical network during and after installation.- 2.5mm universal connector- Operates either in CW or Pulsed- Constant output power- Long battery life (up to 60 hours)- Laser case ground design prevents ESD damage- Portable and rugged, easy to use- Burning testing to ensure the reliability.- Optional 1.25mm connector adapter

  • Gasmet Portable FTIR Ambient Air Gas Analyser

    DX4040 - Quantitech Limited

    The Gasmet DX4040, the only truly portable FTIR gas analyser in the world, is a lightweight battery operated system capable of measuring multiple gases (both organic & inorganic) at low concentrations simultaneously in real-time. The system has been developed based on the highly successful Gasmet DX4030 and shares the same optical components and internal hardware. Significant advances have been implemented to the operating software and control apparatus to make the Gasmet DX4040 one of the most versatile gas analysis solutions available.

  • NanoSpectralyzer

    NS1 - Applied NanoFluorescence, LLC

    ANF offers the NS1 NanoSpectralyzer®, a unique automated fluorimetric analyzer based on the most advanced research in nanotube spectroscopy. This patent-pending instrument combines a specialized optical system with custom software to enable efficient, turn-key analyses of bulk SWNT samples. The NS1 NanoSpectralyzer is valuable for tuning the process conditions in SWNT growth reactors, for quality control, for guiding nanotube sorting and separation methods, and for a wide range of research applications that require detailed compositional data on a rapid time scale.

  • Laser Spectrum Analyzer

    771 Series - Bristol Instruments, Inc.

    The 771 Series Laser Spectrum Analyzer from Bristol Instruments combines proven Michelson interferometer technology with fast Fourier transform analysis resulting in a unique instrument that operates as both a high-resolution spectrum analyzer and a high-accuracy wavelength meter. With spectral resolution up to 2 GHz, wavelength accuracy as high as ± 0.2 parts per million, and an optical rejection ratio of more than 40 dB, the model 771 provides the most detailed information about a laser’s spectral properties.

  • PXI Dual 2 Channel Fiber MUX SC

    40-855-222-M - Pickering Interfaces Ltd.

    Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.

  • Luminance Meters

    Konica Minolta Sensing Americas, Inc

    Luminance meters are single element detectors that measure photometric brightness. The Konica Minolta luminance meter measures the amount of emitted or reflected light from a surface. These instruments display luminance in either cd/m2 or foot-lambert (ft-L) and they are lightweight, compact and portable. They can be connected to a PC which can store the measurement data and control the device. The LS-160 has a single lens reflex optical system to precisely measure very small (0.4mm) diameters at very short distances, making it extremely easy to use.

  • DCA-X Sampling Oscilloscopes

    Keysight Technologies

    The DCA-X wide-bandwidth sampling oscilloscopes are in our digital communication analyzer (DCA) family. These are modular platforms that provide accurate and precise measurements of high-speed digital designs from 50 Mb/s to 224 Gb/s. You can configure the DCA-X mainframes by selecting from a variety of plug-in modules that perform precision optical, electrical, and time domain reflection / transmission (TDR / TDT) measurements. Select specific modules to obtain the desired bandwidth, filtering, and sensitivity that match your measurement needs.

  • PXI Single 2 x 2 Fibre Optic (M Mode)STM62.5

    40-860-512-M62.5 - Pickering Interfaces Ltd.

    Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.

  • PXI Single 2 x 2 Fibre Optic (M Mode) ST M50

    40-860-512-M50 - Pickering Interfaces Ltd.

    Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.

  • PXI Single 2 x 2 Fibre Optic (M Mode) SC M50

    40-860-212-M50 - Pickering Interfaces Ltd.

    Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.

  • Multi-Wavelength Meter

    86122C - Keysight Technologies

    With an absolute wavelength accuracy of 0.2 ppm and 0.15 ppm differential accuracy, the new Keysight 86122C Multi-Wavelength Meter belongs in the top class of wavelength meters available for optical communication testing. Its wavelength range of 1270 to 1650 nm covers all fiber-to-the-home, metro and long-haul transmission systems. The instrument can measure the spectra of up to 1,000 laser lines at once, which is more than sufficient for fully populated dense-wavelength-division multiplexed systems (DWDM).

  • Laser Heads

    Keysight Technologies

    The laser head is the source of the laser beam used in all laser motion and position measurement systems. The primary difference between laser heads is in the velocity, reference frequency and optical output power. Other considerations are size, heat dissipation, and input power requirements. Which laser you choose depends primarily on the application in which it will be used. For example, semiconductor lithography systems typically have faster moving parts (stages), and therefore need higher velocities than machine tool applications.

Get Help