Showing results: 1981 - 1995 of 4859 items found.
-
QA350 -
QuantAsylum
The QA350 relies on a built-in reference to calibrate the ratio between the hi and low ranges. If you have a preferred lab reference, you may use that it to improve the QA350 accuracy beyond the indicated +/- 400 PPM. For example, various vendors on eBay can provide calibrated +/-30 PPM 5 or 10V voltage references that can be used to set the ultimate accuracy of the QA350 to under 50 PPM at room temperature.
-
-
PSPL03 -
Pyle Audio Inc.
Max Hold FunctionSmall Shape for Easy PortabilityLevel Range: 35-100dBAccuracy: +/- 3dB (ref. 94dB @ 1kHz)Frequency Range: 31.5 Hz to 8 kHzFrequency Weighting: AOperation Temperature: 0 to 40C (32 to 104 F)Storage Temperature: -10 to 60 C (14 to 140 F)Battery Type: 9V (Included)Dimensions: 6.69' H x 2.28' W x 1.38' DWeight: 3.77 oz.Sold as : Unit
-
PTHM15 -
Pyle Audio Inc.
Auto Power OffFast Response TimeDew Point TemperatureDual Display Temperature & HumidityData Hold FunctionHumidity Range: 0-100%RHTemperature Range: -20 - 80 C / -4 - 176 FDew Point Temperature: -20 - 80 C / -4 - 176 FWet Bulb Temperature: 0- 80 C / 32 - 176 FHumidity Accuracy: +/- 3% RHAir Temperature Accuracy: +/- 0.5 C @ 25 CResolution: 0.01% RH, 0.01 C/FResponse Time: %RH: 105 (90% at +25C still air)Battery Type: 9V (Included)Operating Temperature: 32 F to 104 F, <80% RHStorage Temperature: 14F to 140 F, <80% RHDimensions: 6.89' H x 2.28' W x 1.38' DWeight: 5.04 oz.Sold as : Unit
-
CHINO
On-line multi IR wavelength analyzer utilizing infrared absorption technology for measuring product constituent and/or thickness.
-
AMPI-525 -
Amperis sl
*Short circuit loop measurement:*Impedance measurement with 23 A (44 A phase-to-phase), short circuit resistance RZW =10Ω*Measuring range: 95...440V, frequency 45...65 Hz*Short circuit loop measurement with resolution 0,01 Ω , without tripping the differential protections (I∆n ≥30mA)*Automatic short-circuit calculation, phase-neutral and phase-phase voltage detection
-
D348D -
Gentos Measurement & Control Co.
The D348D Plus ultrasonic flowmeter is a high-precision instrument with ultra-high accuracy, linearity, and repeatability, which meets strict measurement requirements.
-
OD-10 -
JFE Advantech Co., Ltd.
Measurement of dissolved oxygen for aeration flow rate control at sewage treatment plants and monitoring of water quality at rivers,lakes,and etc.
-
pH 703 -
Tecpel Co., Ltd.
High quality, light weight and compact design. Measure water pH fast and easily in many fields such as swimming pools, aquariums, cooling towers, water and wastewater treatments, sanitation plants and laboratory applications. High resolution 0.01pH and high accuracy +/- 0.02pH. Comes complete with protective carry case and standard pH7 buffer solution
-
CyberScan pH 110 -
Thermo Scientific
5-point Push-Button Calibration with Auto-Buffer Recognition for quick calibration with no calibration mistakes
-
-
CHROMA-1 -
Lisun Electronics Inc.
• Measure Pa rameters: CCT, Chromaticity Coordinate(x, y, u, v) • Display range: 1500K~25000K, Resolution: 1K • Accuracy: 0.5%F.S. • Luminance test function (lx test)
-
DA-130N -
MRC ltd.
Measuring method Natural Oscillation typeMeasurement object Liquid sample test materialsRange 0.0000 ~ 2.0000 g/cm3Precision 0.001 g/cm3Resolution 0.0001 g/cm3Temperature range 0 ~ 40.0CTemperature compensation Up to 10 entries for temperature compensation coefficient and converted temperatureAutomatic calibration All density values of pure water needed for auto calibration can be stored.Number of data 1,100 samplesExternal outputPC or Printer can be connected. (not both) IrDA interface is standard equipped. Connection via RS-232C requires optional infrared RS converter (98-029-0007).
-
DSM3700 -
ZOGLAB Microsystem Co., Ltd.
Fully coated with steel, progressive class of IP68 Unique temperature sensing design shortens measuring time Wide viewing angle for fast and accurate data reading Super-low current consumption ensures built-in battery to continuously work for 3-5 years
-
Laurel Electronics, Inc
Accepts low-level differential or single-ended 5 V logic level quadrature signals from shaft encoders to display scaled position or scaled rate. One, two or four transitions may be counted at a maximum combined rate of 250 kHz and be mathematically scaled to display in engineering units from -999,999 to +999,999. An analog output scaled to the display and relay outputs are optional.