Showing results: 1381 - 1395 of 4859 items found.
-
OCC-50 -
ShinewayTech
OCC-50 Handheld CWDM Optical Channel Checker is specially designed for CWDM installation, maintenance and troubleshooting, which is able to measure and monitor power values of up to 18 CWDM channels. OCC-50 can replace high-cost spectrometers and conduct quick and reliable measurements in all environments. Thanks for its light, compact and sturdy design, OCC-50 is the ideal tool for CWDM installation and maintenance technicians.
-
NivuFlow Mobile 600 -
NIVUS GmbH
The NivuFlow Mobile 600 was developed particularly for long-term measurements in field operation without external power supply. Measurements for checking and verifying can be carried out with the self-sufficient and portable system without any problems even in harsh environments. Battery lifetimes of several weeks or even months reduce personnel costs for maintenance and data readout significantly.
-
DIGI-FIELD -
I.C. Engineeering
Measuring radio frequency and microwave radiation has never been easier! This unit covers the amazing range of DC - 12 GHz and will give you digital readout of the relative field strength of broadcast signals such as cellular phone, microwave oven leakage, TV station, CB radios using the (1MHz - 1GHz) telescoping antenna provided.
-
MFJ-805 -
MFJ Enterprises, Inc.
Use this ultra-sensitive pocket-sized RFI Detector to track down and eliminates RFI caused by radiating cables and wires. Usable from VLF to VHF. Gain adjustable over 50dB range.
-
Handheld Turns Ratio & Winding Resistance Tester TWR-H -
Amperis sl
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
-
D116-PT1000 -
Gentos Measurement & Control Co.
D116-PT1000 is an upgraded version of D116, adding heat measurement function, so it can detect flow rate and calorie consumption of the fluid at the same time.
-
1503 -
Fluke Corporation
The Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.
-
SME1202 -
Scientific Mes-Technik Private Ltd
General purpose insulation resistance meter Analog indicator, High measurement speed Test voltage range: 10 V to 1000 V Suitable for Testing capacitor insulation test Easy operation
-
Changzhou Applent Instruments Inc.
Can scan and test 10 channels of resistance and can set a comparator for each channel. Its temperature compensation function can adapt different testing requirements. It can be applied to automation equipment.
-
PHOTO-100L -
Lisun Electronics Inc.
• Measuring range: 20cd/m2~2000kcd/m2; • Testing accuracy: Class 1; • Display refresh rate: 1times/sec; • Power source: 9V battery; • Power consumption: less than 20mW; • Normal technical specifications: 1) Temperature: 0~40℃, 2) relative humidity: less than 90%
-
Kikusui Electronics Corp.
designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.
-
0870S-5870S -
Hangzhou Softel Optic Co., Ltd.
SLM-5870S operating range: 05 to 870MHz, work with Return path signal generator, it will measure the return path.
-
ACS37800 (Qwiic) -
SparkFun Electronics
The Allegro MicroSystems ACS37800 power monitoring IC greatly simplifies the addition of power monitoring to many powered systems and is ideal for heavy current applications like:*Monitoring the power drawn by a 3D-printer*Monitoring the power drawn from a UAV battery*Battery charging / conditioning*Solar / photovoltaic panel power monitoring
-
Smartech Inc.
- Magnetic induction (F) method is used to measure the thickness of non-magnetic coating on ferrous metal- Eddy current (N) method is used to measure the thickness of non-conducting coating on non-ferrous materials- Automatic recognition of substrate- Automatic selection of measuring methods- 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)- Upper-lower limit setting and sound alarm- Data output to printer or PC by RS232 cable- 500 readings can be stored- 2 measuring modes: continuous / single- 2 stop ways: Manual/automatic