Showing results: 451 - 465 of 4831 items found.
-
-
Sper Scientific
ORP (Oxidation Reduction Potential) measures a system’s relative state for gaining or losing electrons. ORP values are affected by all oxidizing and reducing agents, not just acids and bases that influence pH measurement. In practice, ORP measures the ability of a lake or river to break down waste products, like contaminants and organic matter. When the ORP value is high, there is lots of oxygen present in the water.
-
Wuxi IMHOO Technology Co., Ltd.
1. Residual capacity of battery(Ah or mAh) 2. Capacity percentage and totem pole display 3. Battery voltage 4. Battery current 5. Power output 6. The remaining time of charging and discharging
-
burster präzisionsmeßtechnik gmbh
Developed to monitor hand lever presses. One button operation and data for different processes on PLC-slotcards allow every user quick changes of press fitting procedures. Attractive low cost device for precise quality monitoring.
-
Mk VI -
Versaperm Ltd.
Our broad range of permeability measurements instruments are at the cutting edge of technology and give precise, reliable, easy and fast result. The instruments can be configured for almost any gas or gasses, including water vapour, hydrocarbons, O2, CO2, N2, H2 and He.
-
633 -
Red Phase Instruments Australia Pty Ltd.
This instrument is designed to demonstrate the properties of phasors and real/imaginary number notation for electrical engineering students. This instrument gives the phase displacement and magnitude of the parameter under investigation. The unit has filters to eliminate harmonic distortion affecting phase angle measurement.
-
pH 705 -
Tecpel Co., Ltd.
3 1/2 Digit , Large LCD Display, Max Display 1999. Measuring Range: pH 0.01~14.00 PH. Temperature: 0.1 C~ 65 C ,Millivolt: 1mV¡ã1999m
-
MRC ltd.
* Three reading modes* Smart-Read function. More stable the reading with auto recognition end-point* Cont-Read function. It is clear to read the sample changing in measurement process* Timed-Read function. Auto timed to store the reading* Auto upgrade hardware* Power-off protection, protect your data* Remind the electrode performance and calibration.
-
-
I 520 -
LMT Lichtmesstechnik GmbH
display range 0.01 nA (last digit) to 7 999 μA4-digit display (0-7999) with dimmer for brightness controlV.24-(RS 232-) Interface, analog outputranging auto/manual or remote programmableapprox. 2.5 readings/s, attenuator 100% to 0dark current compensationpower supply for thermostatic stabilized LMT photometer headspower supply 230 V, 50-60 Hz, power cable with Euro plug
-
SX1100 -
Diamond Antenna Corp.
Frequency range:S1 (1.8-160MHz)S2 (430-450MHz/800-930MHz/1240-1300MHz)Power display range:5W/20W/200WAccuracy at full scale:±10% (F.S.)Minimum power at SWR
-
X-COM Systems
All Bird Plug-In Elements are calibrated in accordance with meticulous Bird calibration procedures supported by a long history of mean deviation values to assure adherence to advertised specifications of current instruments, as well as field interchangeability with equipment purchased, used and trusted in all the years since its introduction.
-
-
Kane International Ltd
Suitable for difficult applications such as flue draft measurement & measuring differential pressure of gas/air ratio valves on high efficiency boilers
-
Sparling Instruments
Measures accurately over a flow range of 10:1 or greater.± 2% of rate accuracy, guaranteed by certified wet calibration at three test points in.Sparling’s National Institute of Standards and Technology (NIST) traceable hydraulic flow lab.Sturdy cast or fabricated steel construction.Operating temperatures are over 100° F(unless higher temperature construction is specified).Suspended solids are over 0.5% of volume.Easily maintained with standard tools.Registration can be furnished in any standard Engineering Unit.