Showing results: 1 - 15 of 170 items found.
-
Techimp HQ S.r.L
Techimp Capacitive PD Couplers offer both the PD and sync signals references, allowing a thorough investigation of the signal originating inside the asset they are connected to.Techimp Couplers are individually tested according to the following international standards: IEC60358; IEC60694; IEC60270.
-
Power Diagnostix Systems GmbH
he versatility of the Power Diagnostix line of PD detection equipment is due in large part to the range of accessories available for the ICMseries instruments. Each ICMseries data acquisition unit can be combined with different accessories to suit specific applications.
-
Techimp HQ S.r.L
PDCAL has excellent pulse-with stability; scale calibration factors are permanently stored inside its flash memory. Thanks to on board photo coupler PDCAL output pulse can be synchronized with the actual line frequency through external surrounding electrical light source systems.
-
TECHIMP PD Hub™ -
Techimp HQ S.r.L
Techimp’s Partial Discharge (PD) Monitoring systems usually consists of a Central Unit and distributed Data Acquisition Units – the PD Hub™ - able to acquire and process the PD signals locally detected through PD sensors installed on each of main electrical assets (generator, transformer, HV cables and GIS).
-
Megger Group Ltd.
Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.
-
TEM -
Mess- & Prüfsysteme GmbH
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
ASM-P -
IPEC Ltd.
The ASM-P can be configured with up to 32 PD sensor channels. If excessive discharge is detected, the ASM-P raises an alarm that can be configured either locally or by email/SMS. This enables the long-term assessment of plant conditions to be carried out quickly and easily, from any remote computer.
-
Power Diagnostix Systems GmbH
This group of instruments offer partial discharge measurement functions of different performance level. Devices for test and research laboratories as well as systems for on-site PD analysis are available. Stand alone units, computer controlled systems or wireless operating acquisition sets are shown in this area.
-
AQUILA -
Altanova Group
A compact and portable Partial Discharge acquisition unit, which allows to detect and analyze partial discharge activities in all electrical assets: from power cables to transformers, rotating machines and switchgears, together with the right combination of sensors and accessories. AQUILA comes with a full range of options, ideal for field testing.
-
Shanghai Himalayal Co.
1. Number of channels: 2/4 electric signal interfaces & 1 EXT interface 2. Sampling frequency: maximum 200MGa/s 3. Sampling precision: 12bit 4. Range: 0.1mV~20V 5. Range switch: 1mV, 2mV, 5mV, 10mV, 20mV, 50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V 6. Frequency band range: 1Hz-60MHz 7. Range non-linear error: 5% 8. Range of capacitance for test object: 6pF~250µF 9. Power source mode: internal lithium cell / AC 220V 10. Display: 6.5 inches TFT LCD 11. Resolution: 640×480 12. PV: 4GB 13. Hard disk: 32G stiff disk used for storing the test data
-
Weshine Electric Manufacturing Co., Ltd
TEV partial discharge inspection instrument uses two emerging technologies, transient-to-ground voltage (TEV) measurement and ultrasonic (US) measurement, to detect faults in switchgear. The equipment is portable and easy to operate. The TEV sensor is attached to the wall of the box, and the US sensor scans and detects along the gap on the switch cabinet.
-
Power Diagnostix Systems GmbH
Partial discharge monitoring systems can be used for permanent surveillance of insulation systems on GIS, transformers, rotating machines, motors, cables, or other high voltage equipment. These instruments are designed for long term data recording, alarm handling, event recognition, and system integration.
-
Power Diagnostix Systems GmbH
Offers high speed data acquisition via optical fibers on multiple channels in parallel. Each channel acts as an independent transient recorder with its own storage and settable acquisition speed.
-
Sifos Technologies, Inc.
*Flexibly Mimic Class 0 to 4 Powered Device Per PSA/PSL-3000 Test Port*Configure up to 192 Simultaneous IEEE 802.3 PD’s*User-Defined Class 0 - 4 Powered Device Modeling with or without Cable Loss*Emulate 802.3at PoE-LLDP Negotiations and Power Adjustments*Monitor Multi-Port Live Emulation Status*Available to PSA-3000 and PSL-3000 Platforms as optional license feature
-
PD-SGS -
BAUR Prüf- und Messtechnik GmbH
Quick identification of PD activities in switchgear and cable accessories. The BAUR PD-SGS handheld online PD detector is used to conduct rapid initial tests for PD activities on live switchgear. Potential weak points are immediately signalled acoustically and numerically.* Initial rapid condition evaluation of switchgear and cable accessories during mains operation* Ideal for quick checks of MV and HV switchgear* Two integrated sensors:TEV sensor records PD on the surfaces of switchgearsAcoustic sensor records PD inside switchgears* Greater safety for test personnel switchgear tested for safety risks before starting work