Filter Results By:

Products

Applications

Manufacturers

PD

voltage discharge within an insulator causing dielectric breakdown.

See Also: Partial Discharge, Partial Discharge Detection, Partial Discharge Monitors, PD Test, Partial Discharge Test


Showing results: 136 - 150 of 171 items found.

  • Laser Diode Drivers

    Arroyo Instruments

    Arroyo Instruments offers a broad range of laser drivers to meet your exact test needs. From 100 milliamps to 100 Amps, all of Arroyo Instruments' LaserSource benchtop laser drivers include unique features not found on competing products such as optically isolated photodiode and modulation inputs, programmable PD bias, and both RS232 and USB computer interfaces. The LaserSource also has laser diode protection circuits such as interlock, ESD protection, and hardware limits for current and voltage.

  • PPS Clamp Transformer

    Techimp HQ S.r.L

    PPS2 provides power supply to the PD detectors installed on HV cable when low voltage AC power is not available. The PPS2 takes the required power directly from the High Voltage power line under monitoring by means of units clamped on the HV power cable(s).PPS2 is designed to withstand High Voltage line failure events such as temporary overload and short circuit conditions. An internal detection and self limiting circuitry guarantees that PPS2 and the connected equipment survives in case of such events.

  • Multi Jet Oil Meter

    Smartech Inc.

    Smart Positive Displacement Flow Meters Design Excellence Always Leads To Better Performance. Among the many PD flow meter design principles available today, the oval gear still holds a top place both in simplicity and field proven performance. Smartech Inc offers robust positive displacement oval gear flow meter range incorporating patented innovations & features with Flomec sensor and very strong electronic measurement that brings many benefits to market.

  • Partial Discharge Inductor

    Tracy - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories

  • RFI & Acoustic Signal Surveyor

    DFA300 - Doble Engineering

    Use the Doble DFA300 to identify and locate insulation defects.This surveying tool combines radio frequency interference (RFI) and acoustic emission (AE).The The DFA300 partial discharge detector can locate partial discharge (PD) in a few seconds. Designed for surveying live, high voltage apparatus, its versatility makes it the perfect, multi-purpose tool for condition-based maintenance programs.

  • Partial Discharge Tester

    19501-K/19500 - Chroma ATE Inc.

    Chroma 19501-K partial discharge tester combines hipot test and PD (partial discharge) detector functions in one instrument. The device is capable of a maximum 10kV AC output with leakage current measurement range of 0.01uA and a minimum partial discharge detection of 1pC. The tester is specifically developed to test high voltage semiconductor components and high insulation materials.

  • TEV Antenna

    Techimp HQ S.r.L

    TEV sensor is a partial discharge sensor whose working principle is based on a direct Capacitive coupling with a Switchgears earthed metal case. The two ends of TEV sensor can be coupled magnetically to virtually any opening on a metal Surface. It picks up the electric signal given by PD activity onto the two metallic surfaces. Thanks to its special design has high sensitivity, larger than other single ended TEV sensors. His compact and robust design (passive sensor) makes the TEV the optimal sensor for direct installation on medium voltage Switchgears.

  • PMA Suite For The PSA/PSL-3000: 802.3at (30W) PSE's

    Sifos Technologies, Inc.

    *In-Depth System Testing of 802.3at and 802.3bt 2-Pair PSE's Using PSA-3000 or PSL-3000 instruments*Concurrently Analyze Up To 192 PSE Ports*Robust Emulation of Type-1, Type-2, and Type-3 (Class 4) PD's Including PoE LLDP*Assess PSE Power Administration Decisions*Assess PSE Power Management Behaviors*Static and Transient Reserve Capacity Analysis*Per-Port Variation and Uncertainty Analysis*Assess PSE Power Reliability Over Time*Colorful and Graphical Pop-Up Spreadsheet Reporting*Available to PSA-3000 and PSL-3000 as part of the Live PD Emulation license feature

  • 40Gb/s Coherent Receiver

    Optoplex Corporation

    The integrated 40-Gb/s DP-QPSK receiver incorporates two 90° optical hybrids with four pairs of balanced photodetector (PD) and four linear TIAs into a single butterfly package. Unlike other technologies in which the polarization beam splitter (PBS) and/or the power splitter (BS) are not included, Optoplex’s receiver includes both of them with the optical hybrids, PDs and the TIAs to offer a fully integrated solution which will benefit users in terms of completely removing fiber routing and the skew management. The integrated receivers work at the symbol rate up to 12.8GBaud/s.

  • 100Gb/s Coherent Receiver

    Optoplex Corporation

    The integrated 100-Gb/s DP-QPSK receiver incorporates two 90° optical hybrids with four pairs of balanced photodetector (PD) and four linear TIAs into a single butterfly package. Unlike other technologies in which the polarization beam splitter (PBS) and/or the power splitter (BS) are not included, Optoplex’s receiver includes both of them with the optical hybrids, PDs and the TIAs to offer a fully integrated solution which will benefit users in terms of completely removing fiber routing and the skew management. The integrated receivers work at the symbol rate up to 32GBaud/s.

  • Gas Filled Hv Test Transformer

    YDQW-50KVA/250KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Gas-Filled Hv Testing Transformer

    GTU-300KVA/600KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time. Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Inflatable High Voltage Testing Transformer

    GTU-250KVA/500KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Cable Diagnostic Tools

    High Voltage Inc.

    For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.

  • Battery Cell Insulation Tester

    Chroma 11210 - Chroma Systems Solutions, Inc.

    Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.

Get Help