Filter Results By:

Products

Applications

Manufacturers

PD

voltage discharge within an insulator causing dielectric breakdown.

See Also: Partial Discharge, Partial Discharge Detection, Partial Discharge Monitors, PD Test, Partial Discharge Test


Showing results: 76 - 90 of 171 items found.

  • Horn Antenna

    Techimp HQ S.r.L

    Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.

  • HV Test Transformer

    GTU-800KVA/220KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.

  • Substation Series Testers

    GTPD-92 - Kingrun Instrument Co., Ltd.

    Partial discharge(PD) is a pulsed discharge that produces a series of physical phenomena and chemical changes such as light, sound, electrical and mechanical vibrations in and around electrical equipment.

  • Shielded Rooms

    HIGHVOLT Prüftechnik Dresden GmbH

    Electromagetic field and line-conducted interference needs to be eliminated in order to measure low-intensity partial discharges with a PD background noise level (≤ 1 pC) in accordance with IEC 60270.

  • Smart Sensorgrid NG

    Techimp HQ S.r.L

    Smart Sensorgrid belongs to the smart sensor family devised for on-line monitoring of diagnostic quantities in electrical assets. It provides traffic-light alerts to SCADA systems / asset and maintenance service. Smart Sensorgrid is a state-of-art PD analyzer, exploiting the TECHIMP T-F Map technology (patented). Such feature allows noise rejection and automatic alarm warning based on amplitude and repetition rate trend relevant to statistical parameters. The PD sensor, a HFCT, is integrated in the smart sensor body.

  • Diodes

    Hitachi, Ltd.

    Development target specification*PD=5W class*Capability for load dump surge:ISO7637-2, JASO A-1*Reliability standard:AEC-Q101*Package size:[W×L×H] 12.0×9.6×4.3(mm)

  • Partial Discharge Testing Equipment

    3i - Scope T&M Pvt, Ltd.

    The portable multipurpose 3i device (Intellectual Insulation Indicator) is for eff ective high-voltage equipment insulation monitoring on-line. The 3i device measures and analyses partial discharges (PD). For eff ective PD measurement and noise rejection, there are two types of sensors used in the device: the acoustic sensor and the TEV sensor. Both the sensors are built into the device case, and so do not need any connection cables. The device is supplied in a strong metal case; at the faceplate there are the colored screen and two buttons: power button and function button.

  • LLDP Emulation And Analysis

    802.3at and 802.3bt PD Emulation and Protocol Analysis - Sifos Technologies, Inc.

    *Integrated PoE LLDP and Load Emulation in a Single Instrument*IEEE 802.3at and 802.3bt LLDP Compliance Analysis*Independent, Per-Port 802.3at and 802.3bt LLDP Emulations*Flexible Single and Dual Signature PD LLDP Emulations*One-Click LLDP Protocol Capture and Analysis*Pop-Up Excel Spreadsheet Reports Assess Protocol Content and Timing*Enables One-Click Emulated Power-Ups and Standard Waveforms with LLDP Power Granting PSE's*Enables 2-Pair and 4-Pair PSE Conformance Test Suties with LLDP Capable PSE's*Enables 2-Pair Multi-Port Suite with LLDP Capable PSE's*Available for PSA-3000 and PSL-3000 Platforms

  • Inductive Sensor

    HFCT Ø 30-39-50mm - Techimp HQ S.r.L

    Techimp HFCT is an inductive sensor for partial discharge measurements. It is suitable for on/off line PD tests on many electrical systems (cables, transformers, rotating machine, etc..). It has to be applied to the ground connection of the system to be tested.

  • High Frequency Current Transformer

    HFCT Ø 140mm - Techimp HQ S.r.L

    Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).

  • Sensor Technology

    Power Monitoring and Diagnostic Technology Ltd.

    PMDT is the only manufacturer to utilize all 5 types of online partial discharge sensor technology. Using multiple sensing methods ensures that PD activity is always discovered, located, and characterized. PMDT's handheld PDetector and PDStar units have more capability than the high-end diagnostic equipment of the past. The small handheld, battery powered unit can completely perform the test and analysis without the need of a PC. PDetector, PDStar, and PDiagnostic instruments feature high-resolution phase-resolved analysis of PD signals (PRPD and PRPS) in real time, so you get your test results instantly!

  • 1200kVA High Voltage Testing Transformer

    GTU-1200KVA/600KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.

  • 800 Kv High Voltage Testing Transformer

    GTU-800KVA/800KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.

  • Spiral Antenna UHF Trafo

    Techimp HQ S.r.L

    UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes Spiral antenna the optimal sensor for direct installation on high voltage Transformers. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces. Contact our sales department for consulting.

  • Temperature Controller

    2500 - Dwyer Instruments Inc.

    The Series 2500 Temperature Control provides an impressive array of features in an economical 1/4 DIN package. Features include on-off, time proportioning, proportional, PI, PD, or full PID control, programmable from the front panel, or use Self-Tune PID.

Get Help