Filter Results By:

Products

Applications

Manufacturers

O2

A non metal highly reactive chalcogen.

See Also: Oxygen


Showing results: 76 - 85 of 85 items found.

  • Sample Conditioner

    PCA-400 - Bacharach, Inc.

    Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

  • Optical Oxygen Sensors

    Barben Analytical

    The analyzer is suitable for direct field installation (NEMA 4X) in hazardous area (Class I, Division 2). The optical fiber sensor platform allows small inline sensors to be installed into sample tubing lines (1/4”), flow cells using NPT fittings, or directly into tanks or process lines using our retractable “hot tap” sensor design. BOS optical oxygen sensors are impervious to typical O2 poisons (H2S) and interferences (combustibles, magnetic, CO2 and H2) with high accuracy and long-term stability measurements without the need for complex or advanced sample conditioning systems. The threaded version of the optical sensor has optional Dual Seal (ANSI/ISA 12.27.01) classification for high pressure applications up to 1200 PSIG (82.7 BAR).

  • Motor Vehicle Testing Instruments

    Foshan Analytical Instrument Co, Ltd.

    Possess all manufacturing technology and independent intellectual property right. It conforms to international standards such as OIML R99 and ISO3930Class I. It meets the requirement of dual idle instrument ofGB18285-2005.HC、CO、CO2 are measured by NDIR method and O2,NO are measured by electrochemistry method. Highaccuracy, with automatic compensation for pressure and temperature. With high stability and autom-atic zeroing, there is no need to frequentlycalibrate it with standard gas.It can be used to measure the vehicle using LPG,CNG and alcohol as its fuel,It can be powered by the vehicle battery for the mobile testing station (By using additional power converter,optional part).With bigLCD screen,built-in printer,it has an automatic recording and testingfunction.The rotating speed can be measured viathe cigarette lighter or battery.The two/four gas analyzer can be upgraded to fivegas analyzer.

  • Stack Gas Analyzer

    ENDA-7000 Series - HORIBA, Ltd.

    After decades of experience in precise stack gas measurement, HORIBA's brand new ENDA series represents the ultimate stack gas analyzer. With enhanced lower cost and reduced maintenance time, high sensitivity, and usability, we focused on the users' point of view. The ENDA-7000 is designed to continuously measure the concentrations of NOX, SO2, CO, CO2, O2, and NH3 in stack flue gas streams. The model is offered in dozens of combinations based on your measurement requirements. The ENDA-7000 uses an extractive method which measures undiluted sample gases, and is very suitable to stack gas measurements such as shale gas, LNG, or biogas and other combustion applications. The ENDA-7000 is an excellent choice for measurements in power generation facilities, boilers, furnaces, steel manufacturing, cement plants, pulp and paper mills, etc.

  • Stack Gas Analysis System

    ENDA-5000 series - HORIBA, Ltd.

    Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.

  • Three-Channel Version of Rapidox 3100

    Rapidox 3100 OEM-3 - Cambridge Sensotec Ltd

    The Rapidox 3100 OEM-3 is a three-channel version of our high-performance zirconia oxygen (O2) analyser. Supplied in a metal controller box, the Rapidox 3100 OEM-3 comprises three individual zirconia sensors on bespoke length cables with several options for gas fittings. All three sensor channels are controlled by a single RS485 digital communications link to a PC or PLC using a high-speed USB EasySync device which is included as standard. A special version of our Rapidox software is provided giving full LCD emulation and datalogging of all three channels simultaneously. In addition, a full set of analogue outputs and alarms are provided for each separate channel for more traditional communications needs. We offer a bespoke scope of supply service for customers, which gives a flexible, seamless and cost-effective integration into machinery, products or processes. Please ask us about this service.

  • Oxygen Analyser

    Rapidox 1100 - Cambridge Sensotec Ltd

    The Rapidox 1100 oxygen gas analyser is the company’s most cost-effective and versatile range of gas analysers fitted with either zirconia or electrochemical type gas sensor.The zirconia oxygen sensor is the most common solution providing fast and accurate gas analysis over the range 1ppm to 30% O2 and is particularly suitable for aggressive industrial applications.Users have a choice of two electrochemical oxygen sensors: one for low ppm measurements of 1ppm up to 1% and another for high percent measurements in the 1ppm to 30% oxygen range. Electrochemical sensors are ideal for high oxygen applications or ppm applications where VOC’s, flammable gases, CO, H2 or He is present in the gas sample. A special “oxygen clean” version of the high range analyser is also available.Together the three sensor types offer an oxygen measuring solution for almost any application possible.

  • High Range Chemiluminescence Oxides of Nitrogen Analyzer

    Model T200H - Teledyne Monitor Labs

    The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200H comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

  • ​Mid-Range Chemiluminescence Oxides of Nitrogen Analyzer

    Model T200M - Teledyne Monitor Labs

    The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 ​​converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers. The T200M may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.​

  • Gas Analyzers

    Snap-on Inc.

    Independent Handheld 5 Gas Analyzer or use with MODIS™ Link, VERDICT® and VERUS® Bluetooth® link. Fully Portable 5 Gas Analyzer, go anywhere, use anywhere 110 V AC and 12 V powered Internal rechargeable battery, up to one hour of use Ideal for road testing and mobile use Measures exhaust emissions for CO, CO2, HC, O2, NOx and AFR/Lambda Provides an instant assessment of an engine vehicle exhaust and catalytic converter MODIS, VERDICT® and VERUS® Link for enhanced real-time viewing Setup required with included software on USB stick Gather all the evidence required for effective and accurate vehicle diagnostics on one screen in real time View, graph, save and recall data Monitor and reduce vehicle emissions, improve driveability and fuel efficiency There are 255 memory locations in the analyzer to track and print data for the same or many different vehicles Compatible with gasoline, CNG, propane and diesel fuel types Annual calibration and sensor replacement performed at Crystal Lake Northern Repiar enter Meets required industry standard

Get Help