Filter Results By:

Products

Applications

Manufacturers

Test

to find acceptable or limits of.

See Also: Testers, Testing, Specimen


Showing results: 2461 - 2475 of 14436 items found.

  • BARE BOARD TEST PROBES

    Test Connections Inc.

    Probe Technical DataMechanicalMINIMUM CENTERS: .100 (2.54)FULL TRAVEL: .160 (4.06)WORKING TRAVEL: .107 (2.72)OPERATING LIFE: 1,000,000 cyclesElectricalMAXIMUM CURRENT: 5 amps continuousat working travel, non-inductiveRESISTANCE: At 35 mA test current60 18 mOHMS mean63 60 mOHMS meanMaterials and FinishesPLUNGER: Heat treated beryllium copper60 24 Kt gold plated over nickel63 24 Kt gold plated over nickelBARREL: Nickel silver60 24 Kt gold plated ID and OD over nickel63 No FinishSPRING: Music Wire, 24 Kt gold platedover nickel

  • METES - Meter Test Systems

    KoCoS Messtechnik AG

    Dramatic advances in the field of measurement technology and the use of state-of-the-art micro-electronics have led to the development of a new generation of electricity meters which are far more accurate than their predecessors of just a few years ago. As well as measuring the exact amount of energy used, a high level of integration enables electronic meters to perform a number of additional functions. As a result, these meters are also more sensitive to network irregularities. This means that regular testing is the only way to ensure that a meter functions correctly, both during final factory tests and during the entire life span of a meter.

  • DC High-Voltage Test Device

    PGK 80 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

  • DC High-Voltage Test Device

    PGK 50 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 50. The portable, one-piece PGK 50 high-voltage test device for generating negative DC voltage up to 50 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

  • Camera Barrel Test System

    BK8612 - BaKo Co., Ltd

    We designed the BK8612 2 Channel Noise Test System to provide noise and vibration testing for your digital camera barrel DC Motors. Because it is based on the BaKo BK2120B DAQ, it is capable of monitoring a microphone and an accelerometer concurrently to obtain data from the motor. Because you can change the parameters of functions and limits, it is versatile but still quick and easy to set up. In addition, you can look at data in real time and also store it for future analysis. Easy to use and set up, fast and accurate; if you need to maintain the quality of your camera barrel motors, this is the tester you want.

  • IVTS In-Vehicle Test Set

    LXinstruments GmbH

    The in-vehicle test set was developed to successively measure several active RF amplifiers installed in the vehicle as well as different antenna structures. It offers the possibility to connect 12 DUTs. The DUTs can be connected to an external spectrum analyser via a 1 to 12 RF multiplexer. Each DUT can be individually switched and supplied with an adjustable voltage via a bias-tee integrated in the system. The individual bias voltages and currents are recorded by the IVTS and can be called up on an interactive control panel or via Ethernet and SCPI commands. The complete system can be powered by rechargeable battery and can be operated either via Ethernet, fibre optics or WLAN.

  • Portable Meter Test Kit

    UTEC 430 - Radian Research, Inc.

    The UTEC 430 is the first Portable Meter Test Kit to support both the Radian Dytronic (RD) and the installed base of Radian Metronic (RM) reference standards. The ability to support both reference standards makes the 430 the ideal budgetary solution for traditional on-site meter testing using Phantom Load current sourcing. Do not let its compactness fool you, the UTEC 430 has three 30 Amp current output elements for performing single-phase or three-phase meter testing. When each element is combined using the optional open link cable harness, the UTEC 430 can source up to 90 Amps.

  • Frequency Tripling Test Transformer

    SBF - Wuhan Sangao Electrical Test Installations Limit Co.

    Specificationstripping test transformer1.easy to operate, with stable features.2.Can meet the induced voltage withstand request ofTtripping est transfromer,frequency tripling transformer, frequency tripling generator, frequency power generatorproduct features1.Easy to operate, with stable features.2. Can meet the induced voltage withstand request of the transformer, mutual inductor.product parameters1. Output voltage: three phases 380V 50HZ2. Input voltage: single phase 0~300V/0~500V(continuously adjustable) frequency:150HZ3. Output capacity: 5KVA and above.Harmonic distortion:<5%-8%4. No-load running time:≤5minutes5.duration of the measured equipment under rated voltage: 40 seconds

  • Test Data Investment Services

    PDF Solutions

    PDF Solutions Professional Services offerings cover every major project phase. Available for a specific phase of your project needing a custom solution, or an end-to-end implementation, PDF Solutions Professional Services produces results fast.Realize quicker ROI from your semiconductor test data investmentOffering a broad range of planning, education, design engineering, implementation and support, our team of highly trained semiconductor data integration engineers and analytics consultants can help you build your solution with confidence. These experts can assist your team with:Business Practices AssessmentsBest Practices ImplementationYield AnalysisProduct Characterization SetupSystem DeploymentSite PlanningFlow AnalysisCustom Parser Development

  • Squeak And Rattle Test Solutions

    MB Dynamics Inc.

    sandrAnnoying noises like squeaks and rattles have become a significant quality issue for customers of passenger vehicles, light & heavy commercial vehicles, increasingly off-road vehicles, and even airplane applications. These unwanted sounds are a problem for numerous reasons including customer dissatisfaction, sizeable warranty expense, and the overlying difficulty to diagnose and fix. MB Dynamics offers an innovative line of Buzz, Squeak & Rattle (BSR) or Squeak and Rattle (S&R) Test Solutions, focused on helping to eliminate annoying noises through prevention, design verification testing, and production verification testing, before the product reaches the customer.

  • Communications Manufacturing Test Set

    CMW100 - Rohde & Schwarz GmbH & Co. KG

    The R&S®CMW100 communications manufacturing test set is based on the R&S®CMW platform. The flexible RF interface permits simultaneous testing of up to eight devices. The R&S®CMW100 remote control and measurement concepts are compatible with the R&S®CMW500. The R&S®CMW100 is optimized for cost-effective calibration and verification of wireless devices in non-signaling mode (analyzer/generator). The tester provides a new eco-friendly hardware concept, featuring extremely low energy consumption and a very compact size, making it ideal for use in fully automated robotic production lines. It supports LTE, 5G NR, WLAN, Bluetooth® and IoT technologies, making it ready for today and tomorrow.

  • Universal Launcher Test Set

    TS-217 - Marvin Test Solutions, Inc.

    The TS-217 is an I-level and Depot-level Universal Launcher test set supporting fighter aircraft launchers including the LAU-127, LAU-128, and LAU-129 (AMRAAM), LAU-117 and LAU-88 (Maverick), and LAU-7 (Sidewinder) missile launchers, launcher electronic assemblies, launcher power supplies, and circuit cards. The TS-217 is also used as a depot-level tester for F-18 armament including launchers (LAU-127, LAU-7, LAU-115, and LAU-116), bomb racks (BRU-32), and aircraft pylons (SUU-62 and SUU-63). Additionally, the TS-217 supports MAU-169 Paveway kits, subassemblies, and circuit cards. The TS-217 performs full parametric functional testing as well as troubleshooting to the faulty LRU (I-Level configuration) and SRU (Depot-Level configuration). The TS-217 can be used as an I-Level tester or as a Depot / Acceptance tester for launcher subassemblies.

  • Qualification and Quality Control Tests

    Techsquare - Techimp HQ S.r.L

    New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.

  • Test Bench for Starters and Alternators

    MS004 COM - MSG Equipment

    Compact tabletest bench is used for quick and quality diagnostics of starters, alternators and voltage regulators without applying any additional measuring devices. The test bench possess high power, thus, units can be diagnosed under different loads. The equipment has small dimensions, it can be placed both in small service centers and big shops specialized in selling equipment.The bench includes the following diagnostic functions: testing of 12V and 24V alternators under load, 12V and 24V voltage regulators, 12V and 24V starters in idle running mode.Power supply is single-phase 220V, thus, there is no need industrial power supply.The device carries out testing of different alternators under load up to 100A.Connection of the 2nd battery is conducted from outside to the terminals on the bench body to achieve power supply of 24V for more convenient connection. Thus, usage of the 2nd battery is optional.New algorithms of testing have been implemented, meter accuracy has also been improved.

  • Radiator Flow Test Machine

    8601 - Hydraulic Technology, Inc.

    The Radiator Flow Test Machine P/N 8601 meets all requirements of military specification MIL-F-45955A (AL). It is completely self contained and requires only connection to a source of shop electrical power to place in operation. A power cable complete with three prong grounding plug is permanently attached to the machine for this purpose. The unit consists of a water storage tank, a pumping system, a flow measuring system, a support and workstation, and the required hose adapters for connection to different size radiators. The complete unit is mounted on swiveling casters. The flow rate is infinitely adjustable from 0 to 120 gallons per minute by means of a panel mounted control valve. The machine is constructed from heavy 10 gauge steel, is double welded and is coated externally and internally with a water-resistant epoxy coating. Flow measurement is accomplished by a digital panel meter with a calibrated accuracy of plus or minus 3 percent of scale between 5 and 120 gallons per minute. Higher flows available on request.