Showing results: 5956 - 5970 of 8487 items found.
-
2112/D/H/S-7/HG/Pylon -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 1190Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 13,50 kg
-
MA 2112/D/H/S-7 -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 1190Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 11,30 kg
-
Maschinenbau Haldenwang GmbH & Co. KG.
Test bench for small vehicles with 2 wheelsRoad load simulationDetermination of maximum speedMeasurement and evaluation of speed, speed, distance traveledDisplay of wheel power at test speedDisplay on your PC monitorExpression of test resultsCustomer and vehicle databaseEuro system console MCD 2000 with switching elements for roller setPort for external devices
-
FX Series -
Kyoritsu Testsystem Co., Ltd.
Each FX module is specified one which is suitable for 5 inches bay.You can operate each module on the specified software in PC. It is used USB connection between modules and PC.You can connect MAX 16 modules which include digital IO module,relay module and so on.In case you want to use function inspection system which are combined with several modules, it will implement by our environment generation software(FX-Builder) easily.It is possible to implement by your own software as each module is compatible for Active(X).(Notes)ActiveX is compatible for latest Windows 7 32bit.
-
Genuen
Genuen provides a full range of off-the-shelf and custom dyno test cell solutions. We offer turnkey test cell integration services and test cell upgrades and modernization for all types of dynamometers used in automotive, aerospace, industrial, commercial, off-highway, and agricultural markets. Our broad-based expertise includes dynamometer test systems ranging from AC motor, hydrokinetic, hydrostatic, electric AC/DC, eddy current, and hysteresis brake.
-
ECU-TEST -
Tracetronic GmbH
ECU-TEST is the software for automation tests used in the validation of embedded systems within the automotive industry. It can be used when designing, implementing, and evaluating different tests. It will generate intuitive test reports.
-
Maccor Series 4000, Model 4200, and Model 4300 Automated Test Systems -
Maccor, Inc.
The Maccor Series 4000, Model 4200, and Model 4300 Automated Test Systems can be configured with an M option. This option adds a Multiplexer to the test system which allows the channels to be connected to a Princeton Applied Research PARSTAT 4000 or Solartron Analytical 1260/87 impedance analyzer. With the impedance analyzer connected to the test system via the multiplexer the user can then program impedance tests in the Maccor test procedure which when reached will cause the test system to automatically disconnect the Maccor test channel from the device and connect the impedance analyzer to the device. When the impedance test is completed the test system will then automatically disconnect the impedance analyzer from the device and connect the Maccor test channel back to the device and continue with the programmed test procedure. For the Series 4000 Automated Test System, multiple multiplexers and impedance analyzers may be connected to a single test system. Contact the Maccor sales department with any questions concerning this option and for information concerning other supported models of impedance analyzers.
-
MA 2112/D/H/S-7/GR228x-15/7 -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 1190Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 17,30 kg
-
Circuit Check, Inc.
Flash programming stations allow you to offload flash programming from functional test systems, increasing test throughput while improving capital utilization. Circuit Check flash programmer fixtures support multiple programmer types and multiple I/O configurations.
-
DU7216/7218 -
Delta United Instrument Co., Ltd.
Inductance, Q factor, Leakage Inductance, AC Resistance, Capacitance, DC Resistance, Balance,Turn ratio, Open/Short check
-
PV-215 -
HT Italia Srl
The multifunction device PV-215 allows quickly and safely carrying out the electric safety tests provided for a PV system (section in DC) and the functional test of modules/strings the system consists of according to the requirements of Standard IEC/EN62446.
-
Flexcon Test Connectors
Pin and socket sizes 22, 20, 16, 12 and 8 conform to MIL Spec dimensions. Whenever connector reliability is important, you’ll find NASA-approved FLEXCON test connectors. Applications include electronic, electrical and communications systems, computers, space vehicles, missiles, aircraft and other military equipment.
-
York EMC Services Ltd
The Harmonics & Flicker Generator (HFG01) has been designed for the purpose of verifying harmonic and flicker test equipment. It provides an easy and reliable way to externally check the performance of the measurement system to the EN/IEC 61000-3-2 harmonics and EN/IEC 61000-3-3 flicker standards; particularly important as these tests rely on software control and calculation, and for which there is no intuitive sense of the response.
-
IEC61000 -
Newtons4th Ltd
N4L are the only IEC61000 EMC test system manufacturer in the world* with an on site UKAS ISO17025 calibration laboratory offering accreditation to IEC61000-3-2, IEC61000-3-3, IEC61000-4-7 and IEC61000-4-15. Calibration and trace-ability are a vital aspect of any EMC test solution and the coverage provided through N4L’s UKAS Laboratory is comprehensive. N4L’s IEC61000-4-15 calibration procedure is particularly noteworthy as it covers the entire test protocol detailed in Annex C of IEC61000-4-15. It is commonplace for specific parameters within IEC61000-4-15 (d parameters are frequently omitted from calibration procedures) to remain untested during typical flicker calibration due to the difficulty in providing trace-ability for such measurements. All tests within the test protocol of Annex C are included within the scope of accreditation and calibration procedures at N4L.
-
DU-9001 -
Delta United Instrument Co., Ltd.
The 10 capacitor - LCC/DZ/R in order to automatically scan test improve the test reliability and test efficiencyEach test channel can be opened / short circuit return to zero with high precision.Wide range scan box can be used to test 3mm~35mm 10 capacitorsSuitable for high voltage capacitance test, 450V330uF 10 capacitors can be smooth test