Tektronix, Inc.
8 out of 10 engineers around the world trust Tektronix to help them debug and test tomorrow's designs faster. With the broadest portfolio of digital oscilloscopes available, the richest set of product features, the most extensive analysis capability and our award-winning service and support, Tektronix has the right oscilloscope to meet your needs. Learn more about the different types of oscilloscopes available.
-
Tektronix, Inc.
An oscilloscope is quite possibly the most used piece of test equipment on an engineer’s bench. They are used by electrical engineers or anyone else wishing to measure electrical characteristics of electronic devices. However, you need more than just an oscilloscope to complete your job - you also need one or more oscilloscope probes to make accurate measurements.
-
OT700 series -
Shanghai Tarluz Telecom Tech Co., LTD
SM OTDR, MM OTDR, visual fault locato), PON online test, Optical Power Meter, Optical Laser Source, Fiber Microscope, Ready for all kinds of environment.
-
GAO Tek Inc.
An Optical Time Domain Reflectometer (OTDR) tests the integrity of a fiber optic cable. Using a fiber OTDR, a technician can verify splice loss, identify length, and very easily locate faults in the cable. Another use is to verify the accurate installation of a fiber optic cable when it’s newly installed. If/when problems arise or if an issue is suspected in the future, a fiber OTDR can then compare the images from the original trace to the present state of the cable.
-
Texas Co.
Probes connect the input of the oscilloscope to test points on the device under test (DUT). There are many types, including: high impedance passive, low capacitance, single-ended active, differential active, high voltage, and current probes. This is the first in a series of three articles on probe selection and application, and will focus on passive probes. Part 2 and part 3 will address active probes and current probes, respectively.
-
Aveno Technology CO., LTD.
Other AVENO Test Equipment, including mask & protective cloth testers, cooker & knife testers, battery testers, helmet testers, paper & carton testers, and consumables and tools testers.
-
-
UI-FT36 -
Unuo Instruments
Outsole Belt Flexing Tester, which is also named as Bata Belt Flex Tester, is used to test sole flexing resistance ability. Belt Flex Tester is designed and applicable to SATRA TM133 Resistance to crack initiation and growth–belt flex method.
-
CETECOM GmbH
As a CATL (CTIA Authorized Test Lab), CETECOM is accredited to perform OTA measurements following the specifications of the Test Plan for Mobile Stations Over-theAir Performance. OTA measurements are a requirement to obtain PTCRB certification and compulsory for wireless devices that are launched on the North American market. The globally recognized GCF Regime has similar requirements regarding OTA measurements.
-
O2 -
Bacharach, Inc.
The O2 sensor is used in Bacharach portable combustion analyzers to measure the percentage content of oxygen levels in flue gases. The range of the oxygen sensor is 0 – 20.9%. O2 measurement is used in conjunction with the chosen fuel to calculate the CO2 levels in flue gases. Bacharach portable combustion analyzers only calculate CO2 when oxygen levels are below 16%. Bacharach uses O2 and other readings in determining efficiency rather than CO2 for a more accurate measurement. Measuring oxygen content in the excess air lets you know if you have too much air or too much fuel, allowing you to tune your furnace or boiler to maximum efficiency. Measuring O2 directly can save fuel, and save time during a combustion tune-up test.
-
EKT-2001OZ-HCLSX -
Ektron Tek Co., Ltd.
Designed and manufactured in accordance with ASTM D1149, ISO1431 & JIS K6259 standards. Providing precise and accurate ozone (OZ) concentration environment for rubber and polymer test. Widely applied to (1) Accelerated ageing research (2) Quality control and assurance tests and (3) R&D laboratory formula experiments for cracking resistance.
-
EKT-2001OZ-HCSTX -
Ektron Tek Co., Ltd.
Designed and manufactured in accordance with ASTM D1149, ISO1431 & JIS K6259 standards. Providing precise and accurate ozone (OZ) concentration environment for rubber and polymer test. Widely applied to (1) Accelerated ageing research (2) Quality control and assurance tests and (3) R&D laboratory formula experiments for cracking resistance.
-
EKT-2001OZ-HCSSX -
Ektron Tek Co., Ltd.
Designed and manufactured in accordance with ASTM D1149, ISO1431 & JIS K6259 standards. Providing precise and accurate ozone (OZ) concentration environment for rubber and polymer test. Widely applied to (1) Accelerated ageing research (2) Quality control and assurance tests and (3) R&D laboratory formula experiments for cracking resistance.
-
EKT-2001OZ-HCSLT -
Ektron Tek Co., Ltd.
Designed and manufactured in accordance with ASTM D1149, ISO1431 & JIS K6259 standards. Providing precise and accurate ozone (OZ) concentration environment for rubber and polymer test. Widely applied to (1) Accelerated ageing research (2) Quality control and assurance tests and (3) R&D laboratory formula experiments for cracking resistance.
-
EKT-2001OZ-HPSSX -
Ektron Tek Co., Ltd.
Designed and manufactured in accordance with ASTM D1149, ISO1431 & JIS K6259 standards. Providing precise and accurate ozone (OZ) concentration environment for rubber and polymer test. Widely applied to (1) Accelerated ageing research (2) Quality control and assurance tests and (3) R&D laboratory formula experiments for cracking resistance.