Showing results: 2791 - 2805 of 8655 items found.
-
260-8 & 260-8P -
Simpson Electric Company
Nothing beats a Simpson 260-8 for monitoring fluctuating trends and rates. Portable yet with benchtop accuracy, the 260-8 is ideal for use anywhere -- workshop, lab or in the field. The 260-8P features an additional resettable overload protection circuit and audible continuity checking. Both versions come with batteries, manual and full-size test leads with threaded probe tips and screw-on alligator clips.
-
TEST-GUIDE -
Tracetronic GmbH
Test execution in development projects leads to the accumulation of various reports and data. Test automation intensifies this, producing very high numbers of test executions, which are distributed over several users and test environments. This multitude of test results from different sources can be efficiently managed and analysed using TEST-GUIDE.
-
CAT Advanced Series -
Amperis sl
Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:
-
Selendroid -
Dominik Dary
Selendroid is a test automation framework which drives off the UI of Android native and hybrid applications (apps) and the mobile web. Tests are written using the Selenium 2 client API - that's it! Full compatibility with the JSON Wire Protocol/Selenium 3 Ready.
-
Beijing KeHuan Century EMC Technology Co,.LTD
(7m × 4m × 3m) RF shielding EMC laboratory (anechoic chamber) is constructed by attaching ferrite tiles and microwave absorbing materials after the RF shielding room is built (7m × 4m × 3m) The simple 3m test distance EMC laboratory can perform EMC tests in the frequency range of 30MHz-18GHz.
-
Microwave Factory Co,Ltd.
Anechoic Chamber room of most suitable Automotive devices EMI/EMS test of the method of ALSE, which meet the global standard like a 2004/104/EC, several emmission standard like a CISPR25 which automotive manufacturers in EU/USA refer to, Immunity standard like a ISO11452 and others for the Automotive devices.
-
Eltel Industries
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Eltel Industries
The ANSI Potential Transformer Burden Model PB-96-ANSI is designed for loading the Voltage transformers during accuracy tests as per ANSI standard C57.13. The PB-96-ANSI is a dual input ANSI burden providing the inputs of both 120V & 69.3V. It can be used along with the ELTEL Automatic Instrument transformer Test Set. AITTS-98 to test VTs as per ANSI standards.
-
Eltel Industries
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Model 2399 -
ICS Electronics
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
EM-6917B-1 | 30 MHz To 3 GHz -
Electro-Metrics Corp.
The EM-6917B-1, a hybrid combination of the industry standard biconical and log periodic antennas, delivers an unmatched combination of frequency coverage and high power handling capability. Featuring exceptionally broad frequency coverage of 26 MHz to 3 GHz, the EM-6917B-1 eliminates the need for adjustments or switching antennas in most test applications up to 3 GHz, and it does so without compromising power handling capability for transmit applications.
-
EM-6917C-1 | 26 MHz – 1 GHz -
Electro-Metrics Corp.
The EM-6917C-1, a hybrid combination of the industry standard biconical and log periodic antennas, delivers an unmatched combination of frequency coverage and high power handling capability. Featuring exceptionally broad frequency coverage of 26 MHz to 1 GHz, the EM-6917C-1 eliminates the need for adjustments or switching antennas in most test applications up to 1 GHz, and it does so without compromising power handling capability for transmit applications.
-
-
Concentric Technology Solutions, Inc.
RF Antenna Couplers help create the ideal environment for shield boxes by providing a consist, stable and reliable environment for repetitive over the air (OTA) tests.
-
EM-6946 | 300 MHz – 3 GHz -
Electro-Metrics Corp.
The EM-6946 offers an exceptional combination of frequency coverage of 300 MHz –3 GHz and high power handling capability without compromising the consistent performance versus frequency that makes the log periodic antenna so desirable for test applications.