Showing results: 8446 - 8460 of 8631 items found.
-
310104477 -
Virginia Panel Corporation
The 9025 is a 25 module receiver designed to fit into a standard 19" rack. This model is equipped with a telescopic handle on the right side. This handle is designed to rest flush against the side of the receiver as a standard handle, or can be extended out to the right up to 3" to accommodate a larger ITA enclosure or other obstruction that may prevent normal handle operation/ engagement.As with the standard 9025, a microswitch is included. Mounting flanges and an instrument bracket are also included for slide mounting. A slide kit is required, but not included. See 9025 procedure sheet/ user manual for instructions on choosing the correct slide kit length for your test rack. *Please note: Consult procedure sheet/user manual for information regarding slight slide mechanism bracket protrusion downward into next U height on test rack on both sides of receiver.
-
Virginia Panel Corporation
The G12x Receiver has four removable rubber feet below the platform and also allows for permanent tabletop mounting. Available with 15" or 20" platforms. The G12x accepts ITAs designed for both the G12 and G12x allowing versatility with your test system.
-
Virginia Panel Corporation
Low profile with 1,440 contact points while only using 1U of rack space. Ideal for in-line test applications. Horizontal layout maximizes module positions and minimizes required rack space.
-
Virginia Panel Corporation
G40x is a two tier, 48 module system that enables pull-thru removal of 40 VPC modules, pull-thru adapters and test instrumentation in one piece. It offers 8 standard/90 Series discrete-wire module slots, plus space for 2 iCon modules, as needed. This solution uses 6.75" Series Pull-Thru Adapters.
-
Virginia Panel Corporation
i2 MX, VPC’s handheld ITA offers a configurable connector in a slim 0.8" footprint and provides EMI protection features. With multiple I/O options to choose from, i2 MX allows you to engineer the ideal connector to meet your test application needs.
-
Virginia Panel Corporation
VPC offers several slide kits that are required for all VPC slide mount receivers. Slide kits are sold by length and length is decided by the depth of the individual test rack. Rack extender kits are available for certain slide kits and receivers. Please note, not all slide kit lengths are appropriate for all receivers. For more information, please consult the individual receiver user manual.
-
Virginia Panel Corporation
The Slide Kits for the S6, G12, and G12x allow access to test instrumentation and wiring. Multiple accessories are available for this configuration such as the Cable Tray, the Keyboard Tray Kit, and Adjustable Leg Kit. Slides can support fixture weights up to 180 lbs [81.65 Kg] and up to 350 lbs [158.76 Kg] with legs
-
ST9001D5 -
Shenzhen Star Instrument Co., Ltd.
The ST9001D5 three-phase energy meter test equipment is full-featured and stable. Optional accuracy classes are 0.05, 0.02 and 0.01. The product series include: universal type, smart meter type, high-class reference meter type, and equipotential isolation type. As divided by structure there are combined type and integrated type. The meter test equipment is controlled via PC-based software. Choices of meter position are 3, 6, 8, 12, 24, 32 and 48.
-
ST2302 -
Shenzhen Star Instrument Co., Ltd.
The ST2302 three-phase energy meter field test analyzer reaches accuracy class 0.02. Its stable performance comes from the embedding technology and digital signal processing. It is Windows CE-based and provides 7 inches color LCD display.
-
ST2303 -
Shenzhen Star Instrument Co., Ltd.
The ST2303 three-phase energy meter field test analyzer reaches accuracy class 0.05. It generates stable signals by using ARM and digital signal processing technologies. Its highlights include compactness, light weight and portability. Various supply options, including measuring circuit, external AC power supply and internal lithium battery are offered.
-
ST9020 -
Shenzhen Star Instrument Co., Ltd.
The ST9020 single-phase energy meter test equipment is full-featured and stable. Optional accuracy classes are 0.1 and 0.05. As divided by structure there are combined type, integrated type and auto wiring type. The meter test equipment is controlled via PC-based software. Choices of meter position are 6, 12, 24, 30, 48 and 60.
-
ST6300 -
Shenzhen Star Instrument Co., Ltd.
The ST6300 portable three-phase meter test equipment is suitable to conduct commissioning and testing for energy meter manufacturers and meter test departments. It adopts modular design and incorporates DSP and PWM switching amplifier technologies. Users are able to control the equipment via keypad or PC-based software. It simultaneously measures the errors of three energy meters. It connects to a meter rack via its COM port.
-
ST9020G3 -
Shenzhen Star Instrument Co., Ltd.
The ST9020G3 single-phase meter test equipment is compact, lightweight and portable. It tests 1 to 3 single-phase active energy meter simultaneously. Users may operate the test equipment via keyboard or PC-based software. It also simultaneously measures the errors of three energy meters. It connects to a meter rack via its COM port.
-
Pickering Interfaces Ltd.
The USB Hub's output ports can be connected or disconnected programmatically to simulate the mechanical connection of a USB device to the module. Additionally, each port has the ability to connect and disconnect the power and data paths separately, enabling the simulation of various connection faults. Take a look at our article, "Bringing USB to the PXI Test Environment" .
-
310104498 -
Virginia Panel Corporation
The 9025 is a 25 module receiver designed to fit into a standard 19" rack. This model is equipped with a telescopic handle on the left side. This handle is designed to rest flush against the side of the receiver as a standard handle, or can be extended out to the left up to 3" to accommodate a larger ITA enclosure or other obstruction that may prevent normal handle operation/ engagement.As with the standard 9025, a microswitch is included. Mounting flanges and an instrument bracket are also included for slide mounting. A slide kit is required, but not included. See 9025 procedure sheet/ user manual for instructions on choosing the correct slide kit length for your test rack. *Please note: Consult procedure sheet/user manual for information regarding slight slide mechanism bracket protrusion downward into next U height on test rack on both sides of receiver.