Filter Results By:

Products

Applications

Manufacturers

Test

to find acceptable or limits of.

See Also: Testers, Testing, Specimen


Showing results: 9421 - 9435 of 14455 items found.

  • FiberPulse OTDR

    XO1 - Yamasaki Optical Technology

    FiberPulse OTDRs send pulses down fiber optic networks from one end of the fiber, displaying a trace and reporting all detected events such as splices, connectors, macrobends and fiber ends and breaks. The total fiber length is reported along with name, location, loss and reflectance of detected events. The intuitive keypad design features integrated shortcut keys designed for quickly positioning and analysing events. Another feature of this unit is the Live Optical Signal Detect Function, which tests if the fiber is live before sending the pulse, this can effectively prevent accidental damage to the OTDR and attached communication equipment.

  • Fibre Channel, Ethernet, & MIL-Firewire Protocol Analyzer

    Cipher - Avionics Interface Technologies

    Supports Multiple Network Protocols including Ethernet, FibreChannel, & MIL-Firewire (AS5643) - High Performance Filtering & Search - Built-in protocol decoders for: FC-AE-ASM, FC-AE-RDMA, FCAE-1553, AS5643, Ethernet, IPv4, IPv6, UDP - User defined “protocol decoders” for custom & proprietary protocols - Database architecture for handling very large data sets - Multiple, Simultaneous views of data sets with time correlation of data across multiple views. - Compatible with common network analysis tools such as - Wireshark (e.g. Imports/Exports to PCAPNG) - Compatible with AIT’s Fibre Channel Test - Instruments for live capture, triggering, and filtering.

  • High Frequency Current Transformer

    HFCT Ø 140mm - Techimp HQ S.r.L

    Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).

  • Live Recorder

    Undo Ltd.

    Live Recorder allows Linux programs to make a detailed recording of themselves while they are running, and to load the resulting Undo Recording in a specially configured UndoDB - our reversible debugger for Linux. An Undo Recording allows UndoDB to completely reconstruct everything a program has done, including every memory access and every instruction executed. By using Live Recorder, developers can debug an exact copy of the original program''s execution, allowing them to track down bugs without needing to reproduce them in-house, write test cases or make time-consuming visits to customer sites.

  • Low-Temperature Impact Device

    DWC-1 - Lisun Electronics Inc.

    This low-temperature impact device is compliance with standard requirement of IEC60245, IEC60227, IEC60540, GB5013-2008, GB5023-2008 and GBT2951-2008. It’s used to test all kinds of PVC sheathed cable, wire, soft wire and no sheath of parallel soft PVC insulated impact resistance at low temperature. Specification: • Working temperature: -15℃±1℃ • Impact height: 10~200mm adjustable • Length of specimen: 5D~150D • Material: 304 stainless steel • Completion time once: 3~5s • Completion number of units for once: ≥2pcs • Weight: 100/200/300/400/500/600/750/1000/1250/1500g • Low temperature box to match additionally

  • Miller 400A

    44500 - M. C. Miller Company

    Rugged, lightweight case - safe to use on wet ground• Weatherproof, even with lid removed - IP67 rating for dust and water intrusion• Convenient case lid removal for ease of movement, with test leads attached, to new measurement locations• Resistance measurement range from 0.01Ω to 1.1MΩ • Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 97Hz (the unit’s operating frequency)• Runs on a set of C-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source

  • PCI Express Mini Card Products (mPCIe)

    Acces I/O Products, Inc.

    PCI Express Mini Card, commonly abbreviated as mPCIe, or Mini PCIe, is a newer form-factor for PCI Express devices. Designed with the older Mini PCI standard in mind they are the same basic form-factor (commonly used in small-form-factor devices like laptops and other portables) but lack the retention clips of Mini PCI. Unlike the original PCI Express bus, Mini PCIe provides both the standard PCI Express and USB 2.0 signals, allowing flexibility in peripheral design. The standard is highly suitable for industrial automation and test in vehicle, mobile, or any other shock / vibration sensitive application.

  • Saluki S2106 Series OTDR (up to 45dB)

    Saluki Technology Inc.

    Saluki S2106 Series Optical Time Domain Reflectometer is a high performance multi-function test instrument designed for the FTTx network. The product has a range resolution of up to 0.05m and a ultra-short event blind zone of 0.8m. This product integrates OTDR, LS, OPM, VFL, Event Map (iONM), OLT and OFD function all in one. It adopts touch and button dual operation mode. The product has rich external interface, which can realize remote control through Ethernet interface or two different USB interface for external USB flash drive, printer and data communication with PC.

  • temperature Measurement

    Educated Design & Development, Inc.

    Up to 8 resistance reading channels, 4-wire methodUp to 12 temperature reading chanels, use of Type K, 24 AWG, Teflon thermocouplesIn the Box:8 - data cable (Cat5e) to connect the isolation modules to the Resistance Reading Channels8 - Isolation Module connected between the HOT-30 and EUT (Equipment Under Test) to isolate high voltage8 - Banana Jack Sets (2 red, 2 black), to replace Kelvin Leads in tight places8 - Kelvin Probe Set12 - 72 inch K Type Thermocouple1 - USB2.0 Type A (standard) to Type B USB cable

  • 3D Semiconductor & MEMS Process Modeling Platform

    SEMulator3D - Coventor

    SEMulator3D® is a powerful 3D semiconductor and MEMS process modeling platform that offers wide ranging technology development capabilities. Based on highly efficient physics-driven voxel modeling technology, SEMulator3D has a unique ability to model complete process flows. Starting from input design data, SEMulator3D follows an integrated process flow description to create the virtual equivalent of the complex 3D structures created in the fab. Because the full integrated process sequence is modeled, SEMulator3D has the ability to predict downstream ramifications of process changes that would otherwise require build-and-test cycles in the fab.

  • Break Strength Testing

    National Technical Systems

    To determine the failure point or break strength, you will need to define what a break is (break detector). Generally, there are two common types of breaks: the sharp break is referred to the measurement when load or force drops by 5% from its peak load measurement. A percentage break is another form of break and is generally determined by the sample material and its relationship to load degradation from a peak load measurement. A plastic material will likely have a load drop of 5%, but not represent a break. In this case, a percentage break would need to be applied. In a tensile test, the breaking load is the break strength.

  • Solder Joint Reliability Testing

    National Technical Systems

    Solder joint reliability is defined as the ability of your product’s solder joints to function under given conditions and for a specified period of time without exceeding acceptable failure levels.Whether you are trying to implement a new solder type or new component types, solder joint reliability testing is essential in providing confidence that your product will perform within its intended operating limits. The results from different test programs can be compared to provide an understanding of design requirements for adequate reliability. This provides you with useful technical information for future designs, saving you time and money.

  • Millimeter-Wave Noise Source, R-band, 26.5 to 40 GHz

    R347B - Keysight Technologies

    The Keysight R347B noise source covers a 26.5 to 40 GHz frequency range. This waveguide noise source allows you to make accurate and convenient noise figure measurements on millimeter-wave devices. The R347B provides highly precise broadband noise at the input of the system or component under test. The noise figure meter then processes the ON/OFF ratio of noise power present in the system IF, and provides an accurate reading of noise figure and gain. The R347B noise source has remarkable ENR stability over time, which allows longer recalibration cycles and more accurate noise figure measurements.

  • Noise Source, 10 MHz to 18 GHz, nominal ENR 15 dB

    346B - Keysight Technologies

    The Keysight 346B noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 18 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. The 346B's high ENR, low SWR, and variety of connectors make it a general-purpose noise source. Add special option H01 for high ENR (21 dB typical) to measure high noise figure devices, or option H42 for measuring Direct Broadcast Satellite (DBS) low noise block converters.

  • Instrument Bracket Kit, w/ Strain Relief, Slide Configuration, for 28"+ Slide Kits

    310113002 - Virginia Panel Corporation

    Instrument Bracket Kit, w/ Strain Relief, Slide Configuration, for 28"+ Slide Kits Similar to instrument bracket p/n 310113453, but includes cutout to accommodate air intake on NI PXIe-1088 chassis. Only compatible with slide configurations 28" and longer. Not compatible with cable tray. Not recommended for use with 2+ tier 90 Series systems (905, 9075, etc.).Used to mount testing instrument to slides and also allows test instrument to slide out for maintenance access. Provides strain relief in front area of bracket. Compatible with chassis (see drawing for more information)

Get Help