Filter Results By:

Products

Applications

Manufacturers

Frequency Standards

Devices that produce a known frequency.

See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks


Showing results: 331 - 345 of 482 items found.

  • Passive Probes

    Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

  • Automatic Frequency Sweep Signal Generator

    GVS7116 - Hangzhou JiGao Electroacoustical Science and Technology Co.,Ltd

    GVS7116C automatic frequency sweep signal generator is an instrument designed for detecting various electroacoustic components (Rattle & Buzz) and its dynamic test. It is suitable for use in the R & D department, quality control department and production line of manufacturers of speakers, headphones, receivers, buzzers, sirens, etc., as well as for the inspection of incoming materials in factories that manufacture various electroacoustic products. Such as audio factory, telephone factory, earphone factory, speaker factory, computer multimedia factory, etc. Standard sine wave, low distortion, best for listening to noise from speakers.

  • Computer-Based Instruments

    GT210PXIe - Guide Technology, Inc.

    With the GT210PXIe you can determine any frequency to 0.01 part per million (eight digits) in just 1 mS, and resolve each time measurement to 8pS. Couple that with 2300 measurements per second, one of the fastest rates available and you can acquire more data in a single second than a typical GPIB counter can in one minute! Faster measurements and higher resolution, along with built-in statistics functions give you a more thorough analysis of your signal. Standard deviation, peak to peak jitter, or a graph of the measurements are available at the push of a button.

  • Computer-Based Instruments

    GT210PCIe - Guide Technology, Inc.

    with the GT210PCIe you can determine any frequency to 0.01 part per million (eight digits) in just 1 mS, and resolve each time measurement to 8pS. Couple that with 2300 measurements per second, one of the fastest rates available and you can acquire more data in a single second than a typical GPIB counter can in one minute! Faster measurements and higher resolution, along with built-in statistics functions give you a more thorough analysis of your signal. Standard deviation, peak to peak jitter, or a graph of the measurements are available at the push of a button.

  • Computer-Based Instruments

    GT210PCI - Guide Technology, Inc.

    with the GT210PCI you can determine any frequency to 0.01 part per million (eight digits) in just 1 mS, and resolve each time measurement to 8pS. Couple that with 2300 measurements per second, one of the fastest rates available and you can acquire more data in a single second than a typical GPIB counter can in one minute! Faster measurements and higher resolution, along with built-in statistics functions give you a more thorough analysis of your signal. Standard deviation, peak to peak jitter, or a graph of the measurements are available at the push of a button.

  • Power Quality Analyzer

    PQM-703 - Sonel S.A.

    Power quality analyzer PQM- 703 is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x . In relation to the PQM -702 has new functions like recording of transients with max. sampling frequency 10 MHz (rapid changes in voltage) and control signals. Minimal transient capturing time is 650 ns. It is intended for a very wide range of users who need to control the quality of power with a mobile device , which fulfills the requirements of a multi-sheet standard IEC 61000 for class A analyzers. This applies to measurement accuracy, measurement methods, and synchronization of time with a standard signal. The last condition is met with a built-in GPS module with an internal antenna. If the analyzer is installed inside, it is possible to use an additional antenna with a 10m-long wire. If the antenna is situated outside, GPS signal will be attainable without any problems and used for the synchronization of an internal clock.

  • Universal Amplifier Heatsinks

    ERAVANT

    A universal heatsink, which is designed and fabricated for Eravant's active device applications with up to 15-watt power dissipation. The heatsink consists of the main heatsink body, a DC fan and a heat spreader. The heat spreader is also known as adapter, which is used to bridge the mounting gap between the heat sink main body and the to-be-heat-sunk devices, such as power amplifier, frequency active multiplier, oscillator, transmitter and transceiver due to various mounting hole locations. The heat spreader offers various mounting patterns to accommodate more than 15 product models. This heatsink is not only designed for Eravant's standard products and Uni-Guide™ featured products, but also for many industrial standard microwave and millimeter wave products offered by other manufacturers. Other heatsinks with different power dissipation capacities are offered under different model numbers.

  • Vehicle Electromagnetic Field Exposure Test System

    SEM-400 - Beijing KeHuan Century EMC Technology Co,.LTD

    Vehicles are our daily public transportation. Electromagnetic pollution in vehicles has attracted more and more public attention. The newly revised compulsory standard GB27630-201X "Passenger Car Air Quality Evaluation Standard" intends to require the electromagnetic field in the car as one of the indicators, according to GB/T37130-2018 "Measurement method of vehicle electromagnetic field relative to human exposure" The measurement method is to measure the intensity of the magnetic field in the car. In the frequency range of 10Hz-400kHz, the electromagnetic field measurement result should meet the public limit requirements of GB8702-2014 for electromagnetic exposure.

  • Standalone Modules

    Optical Zonu Corp.

    Optical Zonu’s RF over Fiber product line contains multiple stand-alone modules which are designed to integrate easily with your application. Each of our stand-alone modules is a Transceiver (TRx), but it may also be configured as individual Transmitter (Tx) or Receiver (Rx) units. A pair of these transceivers creates two-way bidirectional RF to Optical and Optical to RF link. Standard operational frequency ranges between 47 MHz and 3 GHz but can be extended to from 10 KHz to 3.3 GHz. OZ816 and OZ1606 modules have ultra-broadband capability that ranges from 47MHz to 7 GHz.

  • Power Monitor

    Extech PM120 - Extech Instruments Corporation

    Monitor and record power usage of home and work appliances for energy conservation and cost reduction analysis with the Extech PM120 Power Monitor. This helps you determine if the electrical device should be replaced with a higher efficiency unit. The PM120 has a large dual LCD. The primary display shows voltage, current, power, power factor, and frequency readings. The secondary display shows total time, cost (cost of operation per minute, day, or week), set, or energy. Design includes a standard, North American 3 prong plug, front socket connection, and backup battery that saves customized programs.

  • 2-Channel 400MHz DDS Signal Generator

    2940A - Novatech Instruments , Inc.

    The 2940A is a two-channel 400MHz DDS Signal Generator that generates two independent sine wave output frequencies simultaneously from 200kHz to 400MHz in 1Hz steps. A Clock Generator configuration with ECL or LVDS clock outputs is also available. The 2940A is lockable to an external frequency standard or is used with its internal TCXO. Optional internal amplifiers and 60dB step attentators available. Set all parameters with front panel controls and LCD display or by computer using the RS232 serial interface. All settings can be saved into non-volatile EEPROM memory upon power down. Windows software included.

  • Switchable Optical Interleaver

    Optoplex Corporation

    In a switchable interleaver, there are two operation modes: *Mode A: All pass *Mode B: InterleaverIn Mode A, the system operates at any channel spacing, in which all channels pass through the device and output from one of the two output ports as if there is no extra device inserted. When the system is switched to Mode B, the device operates as a normal optical interleaver, such 50-100GHz interleaver. The working principle is schematically shown below. In Mode B, the device could be a standard symmetric interleaver, or an asymmetric interleaver. Channel spacings are not limitted to 50-100GHz. They can be any frequency pair: between N-GHz and 2N-GHz.

  • Multifunction Electrical Installations Meter

    MPI-520S - Sonel S.A.

    The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.

  • Phase Noise Generator / Calibrator

    PNG-A - Noise eXtended Technologies S.A.S.

    The PNG-A is a high precision generator used in Test and Measurement instruments calibration. It is a Signal Generator with precisely computed phase and amplitude noise characteristics. With its wide frequency offset range, 1Hz to 1 MHz offset, and its programmable Phase and Amplitude noise in real time, this is the ideal standard to calibrate phase noise analyzers, Signal Source Analyzers and Spectrum Analyzers.

  • PXI-5671, 2.7 GHz RF Vector Signal Generators

    779079-04 - NI

    2.7 GHz, Digital Upconverter Included, PXI Vector Signal Generator—The PXI‑5671 features quadrature digital upconversion, which reduces waveform download and signal generation time. It is a general-purpose vector signal generator that can generate standard modulation formats such as AM, FM, PM, ASK, FSK, MSK, GMSK, PSK, QPSK, PAM, and QAM. The PXIe‑5671 delivers a highly flexible and powerful solution for scientific research, consumer electronics, communications, aerospace/defense, and semiconductor test applications as well as emerging areas including software-defined radio, radio frequency identification (RFID), and wireless sensor networks. For specific communications standards, you can use various software add-ons to generate modulated signals according to standards such as WCDMA, DVB‑H, and ZigBee

Get Help