Showing results: 16 - 30 of 152 items found.
-
Thorguardian -
THOR GUARD
The THORGUARDIAN is the first, totally integrated advance warning system for lightning. The sensor continuously monitors the atmosphere's electrostatic energy as far away as 15 miles and evaluates the potential for lightning within an area of approximately 2 miles in radius.
-
STT-LSG-7K16A -
Beijing KeHuan Century EMC Technology Co,.LTD
The lightning surge generator STT-LSG-7K16A provides a common basis for evaluating the performance of equipment power lines and internal connecting lines when they are subjected to high-energy transient interference from switching and natural lightning strikes. The performance meets the requirements of IEC61000- 4-5 and GB/T17626.5 standards.
-
LSS Series -
Noise Laboratory Co.,Ltd.
A simulator to reproduce “High energy induced lightning noise” which is induced by potential change on the ground, or done to power lines or telephone lines as result of lightning current.This immunity test is required by major standards including IEC61000-4-5 and JEC 210/212 and is widely used in many industries.
-
CDR-401 -
Cirprotec, S.L.
CDR-401 is the new counter which complies with the latest applicable Lightning Protection related Standards.
-
Boltek Corp.
Check out all of our accessories for a perfect compliment to any of our lightning detectors. They are designed fora wide range of applications and installation setups, and even for a more personalized custom setup, or simply tohave on hand for spare replacement parts.
-
SkyScan -
Xtreme Research Corp.
The SkyScan detects electromagnetic emissions from individual lightning strokes, and can be detected at long range by use of ad hoc sensors. It is a hand-held instrument with an electronic system to detect the presence of lightning/thunderstorm activity occurring within 40 miles of your location.
-
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
SKS-0506IA -
Shanghai Sanki Electronic Industries Co., Ltd.
The lightning surge generator SKS-0506IA fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; it provides pulse test voltages up to 6kV; both AC and DC samples can be tested. The rated voltage of the equipment under test can reach 380V, and the rated current can reach 32A; 7-inch color LCD touch screen, friendly human-computer interaction interface, higher intelligence and more user-friendly operation; the software is built with the level specified by the IEC standard Mode, can be called directly.
-
SKS-0506IB -
Shanghai Sanki Electronic Industries Co., Ltd.
The lightning surge generator SKS-0506IB1 fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; provides a pulse test voltage of up to 6kV; both AC and DC samples can be tested , subject to The rated voltage of the test equipment can reach 400V, and the rated current of the three-phase equipment is higher than 32A; 7-inch color LCD touch screen, friendly human-computer interaction interface, more intelligent and more user- friendly operation; the software is built in the IEC standard Level mode can be directly called.
-
SEN-39001 -
Playing With Fusion Inc
Breakout board for the AS3935 digital lightning sensor based on the AMS reference design. Includes specially tuned antenna, SPI or I2C interfacing, and a wide 2.4V to 5.5V standard operating range. This innovative sensor is designed to interface with most current development systems and boards, including all current Arduino modules. The breakout board features an inductor (antenna) specially designed for this application, and the board ships fully calibrated. This ensures that you don't have to write a massive back-end to support low-level IC calibration, just focus on your final application!
-
SKS-0510I -
Shanghai Sanki Electronic Industries Co., Ltd.
The lightning surge generator SKS-0510I fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; it provides pulse test voltages up to 10kV, which can meet the severity levels of various product standards; Covers the two surge waveforms specified in the standard 1.2/50ms (short-circuit current is 8/20μs) and 10/700ms (short-circuit current is 5/320μs), and a variety of internal resistances are built-in for customer use; Two kinds of surge waveforms, and built-in a variety of internal resistances for customers to use; AC and DC samples can be tested, the rated current can reach 32A.
-
CDN-5811 -
Shanghai Sanki Electronic Industries Co., Ltd.
CDN-5811 signal line/data line coupling and decoupling network is suitable for 1.2/50us symmetrical high-speed communication line, designed according to Figure 11 of the new standard IEC61000-4-5.Ed3.
-
CDN-58A4 -
Shanghai Sanki Electronic Industries Co., Ltd.
CDN-58A4 signal line/data line coupling decoupling network, suitable for surge pulse and ring wave pulse unshielded symmetrical communication line, according to the new standard IEC61000-4-5.Ed3. Appendix A Figure A4 design. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.
-
CDN-5810 -
Shanghai Sanki Electronic Industries Co., Ltd.
CDN-5810 signal line/data line coupling decoupling network, unshielded symmetrical communication line suitable for surge pulses and ringing wave pulses, designed according to Figure 10 of the new standard IEC61000-4-5.Ed3. It also satisfies ringing Figure 10 requirements of wave standard IEC61000-4-12.Ed2. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.
-
CDN-5809 -
Shanghai Sanki Electronic Industries Co., Ltd.
CDN-5809 signal line/data line coupling decoupling network, unshielded asymmetric communication line suitable for surge pulses and ringing wave pulses, designed according to Figure 9 of the new standard IEC61000-4-5.Ed3. It also satisfies vibration Figure 9 of the ring wave standard IEC61000-4-12Ed2 requires unshielded asymmetry. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.