Showing results: 136 - 150 of 154 items found.

  • Calometric Power Meter

    M1-25M/XXE - Elmika

    The M1-25M/XXE series instruments are high precision broadband Calorimetric Sensors operating in millimeter and sub-millimeter wave range on a principle of substitution of microwave power by direct current power, using an autocompensating transistor transducer. Calorimetric Sensor is supplied with Calorimetric Power Meter M1-25M (measurement and indicator block), which provides PC connection via USB interface.Calorimetric Power Meter with Calorimetric Sensor provides accurate absolute power measurements in single mode and multimode waveguides (Metal Dielectric Waveguide) which could be a priority for terahertz physics and technology.

  • Reflection Meter

    RC-088 - Rinch Industrial Co.,Limited

    This instrument is a special equipment for measuring the reflectivity of rearview mirror (or similar product) of motor vehicle. The product composes intelligent measuring instruments, optical integrating sphere, parallel lamp, standard light source, constant current source etc. It is easy to operate,it can measure the reflectivity quickly and accurately. On instrument structure, it adopts standardized modulation design. It takes latest single chip as its digital central processing element. After the measuring signal is converted by modulus, CPU will do some computation and compensation. The instrument can display the reflectivity of device which is measured in rear time. It operates simply and quickly, the indication is direct and accurate. It’s good for quality examination &control in the production scene as well as laboratories. This product has the convenience &quick demarcation way, can meet requirement of different occasion. It is applicable for measuring light reflection on mirror and not mirror parts.

  • High-Dynamics PIMag Linear Stage

    V-522 • V-524 • V-528 - Physik Instrumente GmbH & Co. KG

    Reference-class linear stage. Linear positioning stages with magnetic direct drives largely dispense with mechanical components in the drivetrain and the drive force acts directly on the motion platform. Together with precision bearings, a high travel accuracy and longer lifetime is achieved. The linear positioning stages are particularly suitable for scanning applications. PIMag® Voice Coil. Voice coil drives consist of 2 essential components: A permanent magnet and a coil, which is located in the air gap of the magnetic field. When current flows through the coil, it moves in the magnetic field of the permanent magnet. The direction of motion depends on the polarity. Thanks to their low weight and friction-free drive principle, voice coil drives are particularly suitable for applications, which require high dynamics and high velocities at limited travel ranges. High scan frequencies and precision positioning are also possible with these drives, because they are free of the effects of hysteresis.

  • Power Analyzers

    PCE Instruments

    At PCE Instruments you will find a power quality analyzer to measure the power in W, kWh or to analyze and measure harmonics. This power analyzer is a multi-function power analyzer device that measure precisely direct current, alternating current, AC-voltage, DC-voltage the intensity of DC or AC, phase rotation and idle, apparent and effective power. The reading of AC power is considered the real value and has a maximum range of 6000 Watts. While a reading is being taken, the polarity changes automatically, if negative values are taken then a minus sign will appear on the device display.Nowadays, power quality analyzers have many features such as, insulated current input, measurement of harmonics, AC and DC current measurement, AC and DC voltage measurement, frequency measurement, phase rotation measurement and idle, apparent and effective power measurement. All this data can also be logged and analyzed with the delivered PC-Software. Power analyzers of the type PCE PA 6000 can determine the energy in single-phase systems.Power quality analyzers of type PCE-GPA 62 allow the energy measurement in symmetrically loaded three-phase systems. Power analyzers of type PCE-PA 8000, PCE-360 and PCE-830 support professional power and energy measurements in single and three-phase systems.Apart from being used as energy-measuring devices, power analyzers like the PCE-830 can also be used for network analysis and the determination of harmonics and phase rotation. On our website you will find other power analyzers used in the field of electronics.

  • Thermitest

    THW-L2 - Thermtest Instruments

    Designed with speed and operational simplicity in mind, the Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. In less than 2 seconds, a single measurement of small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. Using a non-stationary measurement approach, the THW-L2 uses rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a 60 mm heating wire that is fully inserted into an isothermal sample. A constant current source (q) is used to heat the sensor wire and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) is determined from the plot of temperature rise vs. logarithm of time and is used in the calculation of thermal conductivity (λ). Liquid samples of high thermal conductivity will have a lower slope, while liquid samples with low thermal conductivity will have a higher slope.

  • 28-CH PPI Module

    ND-6058 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 3-CH RTD Input Module

    ND-6013 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 15-CH Isolated Digital Output Module

    ND-6056 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Analog Input Module

    ND-6017 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Relay Output Module

    ND-6063 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • RS-422/RS-485 Repeater

    ND-6510 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • RS-232 to RS-422/RS-485 Converter

    ND-6520 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • USB to RS-422/RS-485 Converter

    ND-6530 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Relay Output & Digital Input Module

    ND-6060 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Astronomy Solutions

    Thales SESO, SAS

    For more than 40 years, Thales has delivered high accuracy optics for ground-based Astronomy all around the world. These optics range from single, but challenging, unmounted optical components up to fully integrated opto-mechanical systems. Our design heritage and past experience in this field cover the design, manufacture and AIT activities of many optics and sub-assemblies used in Telescope instrumentation, such as focal plane assemblies as well as the direct production of telescope mirrors themselves. Several major achievements of Thales ground-based Astronomy products were the Optical wide field corrector for the Dark Energy Survey (lien), the Reference Body for future Deformable Secondary Mirror of the VLT (lien) and different challenging spectrograph optics (Collimator and Cameras) for different Observatories (lien). One advantage Thales has with this activity is that most part of the manufacturing steps involved (i.e. opto-mechanical design, milling/grinding, lightening, polishing and coating) are directly under our control in our own facility. Our current capabilities for the production of optics for ground-based Astronomy are from a few centimeters size up to 2 meters. Thanks to the continuous efforts in R& D and investments into new production machines, Thales is now ready for future industrial challenges including the optical production of some key elements of the E-ELT, GMT and TMT programs.