  • Transformers

    Vertical Space - SV Probe, Inc.

    With our TrioTM vertical and LogicTouchTM fine pitch vertical technologies an interconnect, otherwise known as a space transformer (ST), is used between the printed circuit board and the probe head, transferring the test signal. SV TCL provides a variety of space transformers, each with its own specific benefits and applications. SV TCL offers a number of space transformer options including:

  • Transformer Short Circuit Impedance Tester

    JYW6300 - Kingrun Instrument Co., Ltd.

    This instrument is mainly applicable to low voltage load impedance test of 35kV and above power main transformers (single phase or three phases) in ex-works routine tests, overhaul tests, pre-tests, and acceptance tests.

  • Load Length Meter

    NeonPro

    Design for finding out the total voltage of neon tubes in a circuit, help to Choose correct rating of neon transformer;- Easy to use just like a neon transformer;- With color LED indicators, clearly shows the test result;- With build-in over voltage protection circuit.

  • Current Transformer Tester

    CTT - ndb Technologies Inc.

    The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.

  • Transformer Degaussing Analyzer

    KRI6691 - Kingrun Instrument Co., Ltd.

    The KRI6691 transformer degaussing analyzer injects current into the test winding by applying ±90V voltage, and collects the terminal voltage and winding current to draw the hysteresis characteristic curve. Linear quantitative analysis of transformer remanence can be performed, and rapid demagnetization can be achieved by tracking the hysteresis curve.

  • Gas-insulated AC Test System

    Yangzhou Power Electric Co., Ltd

    The test system is used to do AC voltage withstand test and PD measurement for high voltage insulation products, combined electrical equipment, instrument transformers, etc.

  • AC/DC Hipot Tester

    HDYD-5kVA/50kV - HD Power Test Equipment Co.ltd

    The Hipot test is a nondestructive test which is effective way to determine the insulation strength for electric equipment . Our Hipot Tester can check dangerous flaws and make sure electric equipment continuous working. It is widely used on transformers, switchgear, cables, capacitors,aerial motors platforms and other related equipment like vacuum interrupters, blankets,instruments transformers generators.

  • Handheld Turns Ratio & Winding Resistance Tester

    TWR-H Series - IBEKO Power AB

    Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Switch Module

    STCS PLUS - Altanova Group

    The external module STCS Plus allows to run automatically and with a single set up, any kind of tests on power transformer.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • 1200kVA High Voltage Testing Transformer

    GTU-1200KVA/600KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.

  • 800 Kv High Voltage Testing Transformer

    GTU-800KVA/800KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.

  • OLTC Tester

    JYK-I - Kingrun Instrument Co., Ltd.

    JYK I on-load tap changer tester,OLTC tester,adopting the complete new test principle and microcomputer technology, the instrument can test the performance of the on OLTC of various kinds of power transformers without disassembling transformers, and hoisting OLTC by indicating and printing the parameters such as transition waveform, transition resistance, transition time and three phase simultaneity, which are used to judge the quality of the OLTC.

  • Transformer Ratio Meters

    Handheld Turns Ratio & Winding Resistance Tester TWR-H - Amperis sl

    TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.