Filter Results By:

Products

Applications

Manufacturers

Power Sources

Supply stable and consistant electrical or light energy.


Showing results: 946 - 960 of 974 items found.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • UVA/UVC Light Meter/Datalogger

    Extech SDL470 - Extech Instruments Corporation

    The SDL470 is a UVA/UVC Light Meter and Data logger. The SDL470 can measure both long wave and short wave UV irradiance under UVA and UVC light sources respectively. This meter features a cosine correction filter, data logging to Excel format, offset adjustment for relative measurements, type K/J thermocouple input for temperature measurements (probe sold separately), record/recall modes, min and max readings, data hold plus auto power off with disable function. This product comes with a built-in tilt stand, SD memory card, UVA light sensor with protective cover, UVC light sensor, hard case, universal AC adaptor, and 6 x AA batteries.

  • OTDR Tester

    M-OTDR-502 - Fuzhou Metricu Technology Co Ltd

    Optical Time Domain Reflectometer Wavelength 1310 / 1550nm, max test range 150KM, Dynamic range 28 / 26dB, SOR standard data saving, create PDF/EXCEL format report, stable laser source, support CW/270/330/1000/2000Hz, Test fiber's length, loss, attenuation parameters and event map, locate connection point/fusion point, Automatic analysis of various linkers/fusion points, easy analyze of various events,Support saving curves number ≥30000pcs, loss test, detect the optical or optical components loss value, etc. Test IP camera, optical power meter, visual fault locator, RJ45 cable TDR test, cable tester, cable tracer, etc.

  • Solar Array Simulator

    LXinstruments GmbH

    Among other things, solar array simulators are required for testing satellite power supplies. An SAS (Solar Array Simulator), consisting of an interconnection of several Solar Array Simulator modules, maps the solar panels and displays the individual strings connected in parallel. Optionally, the individual SAS modules are monitored by a Second Level Protection, so that the test object is not damaged in case of errors with the voltage sources. Additional circuitry is implemented via project-specific test modules. The signal path to the DUT can be separated, e.g. for dynamic current measurements.The Keysight Solar Array Simulators used were specially developed for satellite applications and cover the significantly higher requirements regarding the control speed of MPP tracking compared to terrestrial applications.

  • Radiator Flow Test Machine

    8601 - Hydraulic Technology, Inc.

    The Radiator Flow Test Machine P/N 8601 meets all requirements of military specification MIL-F-45955A (AL). It is completely self contained and requires only connection to a source of shop electrical power to place in operation. A power cable complete with three prong grounding plug is permanently attached to the machine for this purpose. The unit consists of a water storage tank, a pumping system, a flow measuring system, a support and workstation, and the required hose adapters for connection to different size radiators. The complete unit is mounted on swiveling casters. The flow rate is infinitely adjustable from 0 to 120 gallons per minute by means of a panel mounted control valve. The machine is constructed from heavy 10 gauge steel, is double welded and is coated externally and internally with a water-resistant epoxy coating. Flow measurement is accomplished by a digital panel meter with a calibrated accuracy of plus or minus 3 percent of scale between 5 and 120 gallons per minute. Higher flows available on request.

  • Wide Mechanical Tuning Bandwidth Gunn Oscillators

    ERAVANT

    Wide mechanical tuning bandwidth Gunn oscillators utilize high performance GaAs Gunn diodes and various cavity designs to yield near full band frequency coverage. Unlike dual-tuner oscillators, frequency and power optimization are accomplished by a single micrometer. Furthermore, these oscillators can be modified into electrically tunable oscillators by replacing the micrometer with an electrical actuator. The wide tuning bandwidth of these oscillators offers a low cost, high performance means of signal generation, making them ideal test sources for labs and antenna ranges. While standard models offer a waveguide interface, a coaxial interface is also available. When used with a Gunn oscillator regulator/modulator (SOR series), these oscillators can produce AM or FM modulated signals for many test applications.

  • Quad RF Driver

    Spectronix

    The Quad RF Driver contains four independent RF channels, each with an RF synthesizer, variable attenuator, and 1W power amplifier.  The RF signal can originate from either the internal synthesizer or an external source via SMA input.  All channels have independent frequency, phase, and gain settings and can be operated in one of two modes.  The “Wideband” mode operates from 35MHz to 2GHz with a 3.472KHz resolution; over this range the frequency roll-off is approximately 0.5dB/100MHz.  “Int-N Phase Adjust” mode allows the user to set and maintain a fixed  phase relationship between all four channels.  This mode is designed to operate between 300 and 460MHz with a 2MHz resolution.  Two additional inputs are provided for an external frequency reference and digital modulation.

  • Chassis - Controls up to 16 8x1 Modules, 32 4x1 Modules or Mixtures or 8x1's, 4x1's, 2x1's and 2x2 Modules in Any Combination or Configuration up for up to 128 Relay Drives

    CXM/128-MF - Cytec Corp.

    These Chassis controls up to 16 8x1 modules, 32 4x1 modules or mixtures of 8x1"s, 4x1"s, 2x1"s and 2x2 modules in any combination or configuration for up to 128 relay drives. LEDs on the front panel show switch and power status. Add Switch Modules, display / driver modules and a Control Module to complete the system or simply buy the chassis wired out to D connectors to control your own relays. A manual control is optional. Chassis is available with sink or source relay drivers from + 5 to + 28 volts, ot TTL drivers for programmable attenuators. Firmware commands for Fade and Handover for WiFi, Cell Phone and WiMax labs. Fully custom systems built with little to no NRE.

  • USB Controlled RF Signal Generators

    Windfreak Technologies, llc

    Windfreak Technologies provides high value radio frequency devices such as RF Signal Generators, RF Synthesizers, RF Network Analyzers, RF Power Detectors, RF Mixers, and RF Frequency Converters. These devices can be used as RF Test and Measurement Equipment and controlled by Labview in an Automated Test Equipment (ATE) setup, or used as bolt-in RF modules in RF communications equipment. All products have innovative, powerful feature sets controlled by internal microprocessors so any settings can be memorized and used with or without a PC. Windfreak hardware also comes with the Labview GUI source code saving the end user hundreds of hours programming custom software.  Use one of our RF Signal Generators or other products risk free.  Return it if you dont like it.

  • Medical Leakage Current Tester

    2675Y - Shenzhen Chuangxin Instruments Co., Ltd.

    The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.

  • LED Solar Simulator

    LumiSun-50 - Innovations In Optics Inc.

    The LumiSun-50™ is a high power, multi-wavelength LED solar simulator that meets IEC 60904-9 Class AAA for spectral match, uniformity of irradiance, and temporal stability. The LumiSun-50 achieves a spatially uniform illumination field from a chip-on-board (COB), multiple-wavelength LED die array. The field of illumination is 50 x 50 mm at a working distance of 200 mm. The LumiSun-50 includes a driver/controller which individually provides constant current to each die in the COB array. Total irradiance of 1.1 sun units is provided and can be decreased to 0.1 suns. The LED light source of the LumiSun-50 is contained within an air-cooled housing that can rotate the angular beam alignment. Adjustment and setting of the optimum light path working distance is visually facilitated by a converging pair of red dot laser pointers.

  • Signal Splitters

    Becker Nachrichtentechnik GmbH

    Becker Nachrichtentechnik GmbH offers a comprehensive portfolio of active multicouplers and bi-directional signal splitters for duplicating RF signals from common sources. The multi-couplers are designed in 50 ohm technology and are available as a 19 ", 1 U devices as well as slot-in modules for our 'Modular RF Systems' platform. With help of the slot-in modules, larger scale distribution structures can be realized in a space-saving and cost-effective manner. Some devices are available in variants for AC or DC power supply and provide service-friendly remote monitoring capabilities. For use in the production of infotainment components special multi-couplers with integrated HF and DC test functions are available. The multi couplers are used in applications like radio monitoring and direction finding, in product development, validation, manufacturing, quality assurance and in the field of research.

  • Multi-Wavelength Planar Lightwave Circuit Splitter (PLC Splitter)

    PLC-1 × 口口口 - Hangzhou Huatai Optic Tech. Co., Ltd.

    Huatai Planar Optical Waveguide Optical Splitter (PLC Splitter) is an integration waveguide optical power distribution device that based on quartz substrate, featured with small size, wide working wavelength range, high reliability and excellent uniformity of optical split, etc. It is especially suitable for connecting local unit with terminal unit in passive optical network (EPON, BPON, GPON, etc.) to achieve optical signal splitting. The main design divide optical signal in optical communication system into multi-way output. The component that we manufactured is with high stability to light source and temperature. And diversified packages can meet customers’ different requirements in application. According to the various requirements, our PLC splitter is with various types: bare fiber type, miniature type, fan-out type, module type, tray type, plug-in type , Blade package type, rack-mounted type, etc.

  • Multi-Wavelength Planar Lightwave Circuit Splitter (PLC Splitter)

    PLC-2 × 口口口 - Hangzhou Huatai Optic Tech. Co., Ltd.

    Huatai Planar optical waveguide optical splitter (PLC Splitter) is an integration waveguide optical power distribution device that based on quartz substrate, featured with small size, wide working wavelength range, high reliability and excellent uniformity of optical split, etc. It is especially suitable for connecting local unit with terminal unit in passive optical network (EPON, BPON, GPON, etc.) to achieve optical signal splitting. The main design divide optical signal in optical communication system into multi-way output. The component that we manufactured is with high stability to light source and temperature. And diversified packages can meet customers’ different requirements in application. According to the various requirements, our PLC splitter is with various types: bare fiber type,miniature type, fan-out type,module type, tray type, plug-in type , Blade package type, rack-mounted type, etc.

  • Safety Compliance Test System

    EN 60601 - LXinstruments GmbH

    Test system for electrical safety compliance testing of medical products in accordance with EN 60601-1, 3rd edition.The system is equipped with three test fixtures which are connected in parallel order to reduce the number of setup tasks for different variants in the course of day-to-day manufacturing processes. Its purpose is to test medical products, e. g. patient monitors, which are employed at hospitals to monitor heartbeat and oxygen saturation.Based on the integrated electrical safety tester by Associated Research, in combination with an AC power source and a switching matrix, it is possible to fully automate tests like for instance AC/DC high-voltage tests, insulation resistance measurements, earth connection tests and leakage current measurements.The required occupational safety is provided by a high-voltage safety hood in accordance with EN 501191. The entire safety technology, as well as the control PC, is mounted in an aluminum-profile cart.

Get Help