Showing results: 586 - 600 of 803 items found.
-
60-772-003 -
Pickering Interfaces Ltd.
The 60-772 is a family of integrated RF matrices suitable for use up to 2.4GHz in a 50 ohm transmission line system. The matrix design permits any single Y input to be connected to any single X input, permitting the concurrent connection of 4 RF paths. All signal paths are bi-directional permitting any connection to be used as an input or an output.
-
60-770-003 -
Pickering Interfaces Ltd.
The 60-770 is a family of integrated RF matrices suitable for use up to 2.4GHz in a 50 ohm transmission line system. The matrix design permits any single Y input to be connected to any single X input, permitting the concurrent connection of 16 RF paths. All signal paths are bi-directional permitting any connection to be used as an input or an output.
-
60-771-004 -
Pickering Interfaces Ltd.
The 60-771 is a family of integrated RF matrices suitable for use up to 2.4GHz in a 50 ohm transmission line system. The matrix design permits any single Y input to be connected to any single X input, permitting the concurrent connection of 8 RF paths. All signal paths are bi-directional permitting any connection to be used as an input or an output.
-
60-771-002 -
Pickering Interfaces Ltd.
The 60-771 is a family of integrated RF matrices suitable for use up to 2.4GHz in a 50 ohm transmission line system. The matrix design permits any single Y input to be connected to any single X input, permitting the concurrent connection of 8 RF paths. All signal paths are bi-directional permitting any connection to be used as an input or an output.
-
60-772-004 -
Pickering Interfaces Ltd.
The 60-772 is a family of integrated RF matrices suitable for use up to 2.4GHz in a 50 ohm transmission line system. The matrix design permits any single Y input to be connected to any single X input, permitting the concurrent connection of 4 RF paths. All signal paths are bi-directional permitting any connection to be used as an input or an output.
-
60-770-002 -
Pickering Interfaces Ltd.
The 60-770 is a family of integrated RF matrices suitable for use up to 2.4GHz in a 50 ohm transmission line system. The matrix design permits any single Y input to be connected to any single X input, permitting the concurrent connection of 16 RF paths. All signal paths are bi-directional permitting any connection to be used as an input or an output.
-
Lotix -
Teledyne LABS
TOC users from around the globe requested an instrument that meets the following criteria: simplicity, performance, and durability.The Lotix TOC Combustion analyzer is designed to accurately measure carbon content in aqueous matrices down to the ppb level. It uses proven high temperature combustion, oxidation of carbon material into carbon dioxide, and detection using a new Non-Dispersive Infrared (NDIR) detector.
-
40-552-002 -
Pickering Interfaces Ltd.
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
40-552-011 -
Pickering Interfaces Ltd.
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
40-552-012 -
Pickering Interfaces Ltd.
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
40-552-001 -
Pickering Interfaces Ltd.
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
Pickering Interfaces Ltd.
Our low-density PXI switch matrix modules are a cost-effective solution for applications that require relatively small matrices in the PXI format. These low-density switch matrices can be expanded by connecting together multiple modules, however, we recommend that users look at the higher density switch matrix modules that involve less user configuration. Reed relay versions use high quality sputtered ruthenium relays that exhibit excellent contact performance under low and medium level switching conditions. For general purpose applications that also require higher power handling, the range of electro-mechanical relays provides an ideal solution.
-
34904A -
Keysight Technologies
The Keysight 34904A module for the 34970A/34972A Data Acquisition/Switch Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your DUT at the same time. Rows or columns may be connected between multiple modules to build 8 x 8, 4 x 16 or larger matrices, with up to 96 crosspoints in a single frame.
-
BIRSTâ„¢ (Built-In Relay Self-Test) -
Pickering Interfaces Ltd.
Verification and diagnosis of complex switching operation in a test system has always been an issue. BIRST (Built-In-Relay-Self-Test) diagnostic test tool provides a quick and simple way of finding relay failures available on some of our LXI and PXI switch matrices.
-
BIRST -
Pickering Interfaces Ltd.
Verification and diagnosis of complex switching operation in a test system has always been an issue. BIRST (Built-In-Relay-Self-Test) diagnostic test tool provides a quick and simple way of finding relay failures available on some of our LXI and PXI switch matrices.