Showing results: 1 - 15 of 27 items found.
-
McLAREN Applied Technologies
The output of the fluid level sensor is a voltage which changes in direct proportion to the level of fluid in the probe. The difference in permittivity between air and the fluid being measured changes the capacitance between the probe's two concentric tubes as the level changes. An RS232 connection to a PC allows the user to calibrate the fluid level and thermal drift compensation. The probe is factory replaceable, allowing the electronics to be re-used should the probe become damaged or if a new probe length is required.
-
LXinstruments GmbH
Multifunctional function tester with parallel test function based on the LXinstruments OTP2 system platform. The system is used for assembly, final test and calibration of liquid and level sensors for commercial vehicles, construction machinery and shipbuilding in a high mix / medium volume environment.
-
Skyray Instruments
Is an analytical technique that can be used to measure elements at trace levels in biological fluids.
-
Omega Engineering, Inc
Measure and control fluid levels in a contained area or facilitate automatic filling and emptying operations with Omega's dependable single and multi-sensor level controllers.
-
Model 2100 -
Electrolab, Inc.
The Model 2100 DLS with High Level Shut-In delivers consistently accurate measurements of different types of fluids in both hazardous and non-hazardous environments. Multiple fluid densities and temperatures do not affect measurement. The DLS with High Level Shut-In effectively measures the level and temperature of a variety of liquids, including Crude oil, Diesel, Kerosene, Condensate, Gasoline, Water, and Others.
-
Omega Engineering, Inc
Designed for continuous level measurement of conductive, non-conductive liquids and other fluid types. Available in many sizes and with a variety of features.
-
TE Connectivity Ltd.
TE Connectivity (TE) offers distinct fluid property sensor technologies to measure fluids. Our tuning fork technology is coupled with efficient software algorithms for accurate measurement of viscosity, density, and dielectric constant. Dedicated applications for our DEF sensors include oils quality sensors (engine, hydraulic, transmission), fluid monitoring, and others. Our urea quality SCR sensors, based on Ultrasonic Technology (UST), perform an analysis of the Diesel Exhaust Fluid (DEF) fluid to provide urea concentration and secure mis-filling protection to the Selective Catalytic Reduction systems. Our highly reliable reed switch technology is combined with temperature measurement for DEF level sensing.
-
1227 -
Dwyer Instruments Inc.
Use Series 1227 as a regular U-tube manometer to read high-range pressure on the right leg, or as an inclined manometer to read low-range pressure on the bottom leg. Simply incline manometer until fluid levels read zero. No spirit level required
-
ifm efector, inc.
*High reliability due to the elimination of mechanical components*Different function principles: Guided wave radar, capacitive and hydrostatic*Devices for limit level detection or continuous level measurement*Clearly visible LED display*Suitable for all common industrial and process fluids
-
ABB Ltd.
ABB's magnetic level gauge switches for point level alarm and/or control can mount to a KM26 magnetic level gauge or an LS Series cage level switch.These switches are completely isolated from the process fluid as they are magnetically activated by a magnet equipped float (KM26) or attraction sleeve (LS Series). The unique magnetic coupling action eliminates seals, diaphragms, springs, and torque tubes common to other level switching alternatives since there is no physical contact with the process fluid. The magnetic coupling also eliminates process connections to the switch; therefore, no isolation valves are required to block off the switch for maintenance. The switch "set point" is easily adjustable without changing any process piping and the result is a more reliable and easier way to maintain level system.
-
Texas Instruments
Ultrasonic sensing is the measurement of the time between an ultrasonic signal being sent and received. The interval between these two signals is typically referred to as time-of-flight (ToF) and depends on the distance the ultrasonic wave travels until it is reflected due to an impedance change and the speed of the ultrasonic wave. The basic equation time = distance / speed can be used to measure fluid level, fluid identification/concentration, flow, or proximity.
-
AMETEK Drexelbrook
The ClearLine in-Line fluid detector is a point level switch that mounts directly into the process piping between two flat-faced flanges. This product is best suited for pump protection and low-level indication below vessels.
-
iCountPD -
Parker Hannifin Corp.
The Parker iCountPD is a highly compact, permanently mounted laser detection particle size monitor that enables continuous monitoring of contamination levels in hydraulic and fluid circuits.Capable of communicating results in ISO4406 / AS4059 or NAS1638
-
iCountOS -
Parker Hannifin Corp.
The iCountOS is a highly rugged portable particle size monitor that can be used for measuring contamination levels in fuels and/or hydraulic fluids. Capable of operation online (direct connection to system) or offline (sampling from tank or reservoir).
-
EZ-10 -
Panasonic Industrial Devices Sales Company of America
The EX-10 is a special Thru-Beam Sensor that was designed for two purposes; to check fluid levels and to detect the level of liquids containing water. The emitter on the EX-10 Sensor uses a particularly strong IR beam to not only penetrate transparent, but also semitransparent or colored containers such as PFA packages or shampoo bottles. Also, the sensitivity of the Sensor is adjustable to allow it to focus on a target, such as distinguishing foam from liquid in drinks, as an example.