Showing results: 3481 - 3495 of 4017 items found.
-
PL2003 -
Ektron Tek Co., Ltd.
Designed and manufactured in accordance with ASTM F414, DOT571.109, F870 & JIS D4230 standards. New generation of PL-2000X series Plunger Testers, equipped with servo-hydraulic system to control the testing speed, are available fpr customers to select the suitable model. Test functions including Radial elasticity test, Tread footprints test, Tire dimension test, Bead unseating test, Lateral elasticity test and Pressure distribution analysi for Footprints.
-
RW-30X / RW-31X -
Radian Research, Inc.
RADIAN RW-30/31X Meter Site Analyzers deliver comprehensive three-phase field testing and site analysis utilizing the Radian Research RX Xytronic series reference standard as its measurement engine. The RW-30/31X provides for testing meters with integrated, precision, true three-phase voltage and current sources or using customer’s load. Choose the RW-30/31X NS (no source) model to test using customer’s load only.
-
LTR600 Series -
Smartech Inc.
Level Test & Calibration Rig – a boon to Petrochemical Refineries & other process Industries – relies on state of the art simple design for Primary & Interface liquid level testing & calibration of various types / models of Level Measurement (& control) devices including Float / Displacer / Radar / Capacitance / Ultrasonic / Magnetic – for both In-built & External Chamber types. Available Ranges / Span are 1000mm / 1500mm & 2000mm (1 / 1.5 & 2 Meters).
-
AM3200-Series -
Maury Microwave Corporation
AMCAD Engineering has created professional, industry-proven pulsing technology for both standalone IV-testing (Pulsed IV, PIV) as well as pulsed-bias load pull (Pulsed Load Pull, PLP) and high-voltage power semiconductor applications. Systems come equipped with a mainframe controller which includes integrated power supplies. Input and output pulser modules (probes, pulsers) are selected for specific applications and are available in bipolar ±25V/1A and high-voltage 250V/30A models.
-
WMA-IB-LN -
Falco Systems
The WMA-IB-LN can be used to double the output voltage of two high voltage amplifiers by driving them in bridge mode, or as high impedance input buffer while maintaining precision and ultra-low noise. The WMA-IB-LN model has been designed specifically for the Falco Systems WMA-200 high voltage amplifier. Two WMA-200 amplifiers combined with one WMA-IB-LN provide unprecedented noise performance and output voltage range.
-
ATI-100 -
Matrix Test Equipment Incorporated
Now, with our ?New? Model ATI-100 you can turn your existing Matrix Signal Generator and Switchable Filter Bank into a full-blown DTS (Distortion Test System). Plug and play is the word, just plug in your Multiple Frequency Signal Generator, Switchable Filter Bank, Spectrum Analyzer, Oscilloscope, Power Meter, Frequency Counter, etc. to allow the following automatic testing with a single insertion of DUT (device under test
-
PowerMAX™ 365 Series -
Spectronics Corp
PowerMAX 365 Series flood lamps feature a panel of 16 powerful UV-A (365 nm) LEDs specially engineered for non-destructive testing applications. These versatile, stationary light sources can be installed overhead or in-line, and can be ganged together to provide an even wider coverage area. UV-A LED panel flood lamps are also available in two standard-intensity models that are designed for NDT inspection applications requiring limited UV-A output.
-
SMX-4XXX (Matrix Switches) -
AMETEK VTI Instruments
The VTI SMX-4xxx Series of matrix cards deliver exceptional performance and reliability by implementing extensive signal path shielding, isolation and built-in health monitoring. Available models with software configurable switch subsystems increase flexibility and help control costs by allowing a single module to be used for different testing requirements. Embedded virtual schematic control further simplifies setup and debugging, allowing all relays to be engaged independent of application software.
-
RDP-20C -
TEGAM Inc.
TEGAM''s Humitran duct probes provide a reliable, accurate, and low cost method for monitoring relative humidity plus temperature. Solid state sensors supply excellent sensitivity, fast response and long term stability. Simple hook up and linearized output permit interfacing with most display or control devices. Model RDP-20C outputs a 4-20 mA current loop for long virtually unlimited cable distances.
-
819A -
TEGAM Inc.
The Model 819A digital thermometer is compatible with type K, J, or T thermocouple probes to provide a wide range of temperature measurements, (-346F to 2502F). The heavy-duty case is specifically designed for durability and resistance to contaminants such as dust and chemicals. It also features a tilt bail for hands-free or bench top operation. An optional protective rubber boot & belt clip, PN#8204, is available to protect the meter against drops and other physical stresses.
-
Kvtester Electronics Technology Co.,Ltd
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
-
KATC-C2 -
The Eastern Specialty Company
Got older, slower equipment? Knopp’s Automatic Current Transformer Comparator (KATC-C2) is faster, more robust and more accurate! Knopp’s KATC-C2 is a high accuracy current comparator that is compatible with all older generation Knopp comparators, and is designed to be a direct, plug-in replacement requiring no modification of the existing Knopp Current Transformer Test Systems. Save time and money on service by upgrading your comparator to our new next generation model!
-
Teledyne Defense Electronics
Teledyne RF & Microwave offers a capable range of high performance IQ Modulators and Image Reject Mixers as well as IQ (Quadraphase) Modulators which can be used on applications from commercial test equipment to space qualified projects. IQM products can be used either as an IQ modulator or IQ demodulator and cover several frequency bands from 1.4 GHz to 18 GHz. Click on the model number to view the available datasheets.
-
DSOX1EMBD -
Keysight Technologies
The IC, SPI, and UART/RS-232 serial decode option for InfiniiVision 1000 X-Series oscilloscopes (DSO models) displays responsive, time-aligned, on-screen decode of Inter-Integrated Circuit (IC), 3-wire Serial Peripheral Interface (SPI), and UART/RS232 serial communication buses. Because it is hardware-based, this option provides the fastest throughput solution for triggering on and analyzing IC, SPI and UART/RS-232 serial buses found in a wide variety of embedded designs.
-
N9935C -
Keysight Technologies
Capture elusive signals with up to 120 MHz gap-free, real-time bandwidth.Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup.Perform over-the-air measurements for 5G NR and LTE.Use GPS/GNSS for geolocation and timestamping.Carry one lightweight unit at 3.4 kg (7.4 lb).What's included:Base model: spectrum analyzer (SA)AC/DC adapterLocalized power cordRechargeable Li-ion batterySoft carrying case with backpack and shoulder straps