Showing results: 136 - 150 of 226 items found.
-
LineTroll 111K -
Nortroll
The unit mounts 3-5m below the conductors and monitors all three phases. The indicator is powered by replaceable long-life lithium batteries which have a lifeexpectancy of 10-15 years. It provides a 360 degree visibility for indication both for transient faults and permanent faults.
-
Weshine Electric Manufacturing Co., Ltd
Transformer K Factor, Power factors(PF)and displacement factors, Short-term voltage flicker, .Three phase unbalance (Current and Voltage), Waveform real-time display(4 channels voltage /4 channels current) True RMS values of voltages and currents
-
ALPS -
GE Digital Energy
ALPS is a multi-function digital protective relay system intended toprovide distance protection for HV or EHV transmission lines. It maybe applied on or adjacent to series compensated lines. It is availablefor single or three phase tripping applications. Typical operatingtimes are to 1 cycle.
-
MegaPhase, llc
Our test & measurement cables provide customers with a competitive edge over ordinary cable designs by addressing three important criteria for testing electronic components and systems: phase stability, insertion loss stability and repeatable measurements for the cable’s useful life.
-
TE30 Lite -
Calmet Smart Calibration Devices
Electricity meters tester class 0.02%. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
M-200 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*The unique U type CT enabled to measure the load current of single or three phase cable without separating the cable to the wires.*33mmφCT window and ultra compact size.*Data-hold function. Especially useful when working in dark or hard to get areas.
-
MEATEST, s.r.o.
Three or single phase electric power/energy calibrator with power quality functions for calibration and testing of grid measuring appliance like power meters, power transducers or power quality analysers.
-
TE30 -
Calmet Smart Calibration Devices
Electricity meters tester class 0.05 and 0.1. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
61800 -
Chroma Systems Solutions, Inc.
Power rating: Up to 300kVA, single or three phase outputOutput Voltage: 0~330V L-N / 0~570V L-L0~400V L-N / 0~692V L-L opt. without using a transformerOutput Frequency: DC, 30Hz~100HzMaximum power delivered down to 200VAC L-NFull 4 quadrant, fully regenerative up to 100% of output current ratingSpecifically designed for PV inverter, Smart Grid and EV related test applicationsProgrammable slew rate settings for voltage and frequencyProgrammable voltage and current limitsTurn on, turn off phase angle controlLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetParallel output for higher power applications (three phase only)
-
Ametek Power Instruments
RF hybrids are used for combining multiple power line carrier (PLC) TX/RX units together onto one cable without causing interference between transmitters and receivers. They are also used for splitting PLC signals to go to two or three phases of a power line.
-
TR-1 / TR-1P -
Raytech AG
Raytech Single Phase Transformer Turns Ratio Meter TR-1/P was designed to be a rugged and reliable automatic transformer Ratiometer. This system has a high degree of accuracy and will test ratios to 4000:1. The design of this test system is based upon the popular Raytech Automatic Three Phase test set: TR-Mark III.
-
HID -
GE Digital Energy
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.
-
Calport 100 Plus -
Calmet Smart Calibration Devices
Three phase instrument transformers and electricity meters tester class 0.1 or 0.2. It makes possible CT and PT testing on site or in the laboratory. We recommend a new replacement - TE30 Working Standard
-
Shanghai Himalayal Co.
Transformer turn ratio meter is special designed for power transformer (single phase & three phases) and instrument transformer testing, suitable for testing in substation, transformer manufacturer, meter manufacturer. It helps to detect faulty transformer winding and tap changer position. It’s fully automatic device, can recognizes winding connection and vector group number of transformer winding. The user only need connect measuring cable and press start button and come out the test result.
-
2J6 -
The Eastern Specialty Company
The Type 2J6 Knopp Uniload Voltage Transformer Test Set consists of three major parts: When the Knopp Precision Transformer in the 2J6 set is compensated for, and used with, a secondary burden of 15 volt-amperes, for example, the ratio of this precision transformer is well within 0.02% and the phase angle is well within 2 minutes. The transformer, in common with other Knopp Precision Multirange Transformers, is wound so that it has practically the same ratio and phase angle accuracy on all ranges.