  • Intrinsically Safe Relay

    SSR-15 - Dwyer Instruments Inc.

    Model SSR-15 Intrinsically Safe Relay offers low power switching with solid state reliability and eliminates explosive conditions. Units are completely encapsulated and impervious to dust, moisture, or foreign material. Model SSR-15 can be mounted in any orientation and is shock and vibration resistant

  • SIL Reed Relays

    Series 105 - Pickering Electronics

    • SoftCenter™ construction• Highest quality instrumentation grade switches• Encapsulated in a plastic package with internal mu-metal magnetic screen• Wide range of switch confi gurations -Form A, 1 Form B, 2 Form A, 1 Form C• Two pole relay requires the same board area as the single pole type• Dry and mercury wetted switches are available with the same pin configuration and footprint.• Many benefits compared to industry standard relays. Learn more here >.• Insulation resistance greater than 10E12 Ohms (1TOhms) for dry Form A devices• 5, 12 and 24 Volt coils are standard, with or without internal diode• 100% tested for dynamic contact resistance

  • Current Protection Relay

    Mors Smitt Group

    The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.The relay is tuned to reject 3rd & higher harmonic frequencies to avoid problems under quiescent conditions. An adjustable time delay is built in to provide stability during switching & other transient disturbances & to allow adequate grading with other protection systems at high fault current levels.

  • Space/Hi-Rel Relays

    Teledyne Defense Electronics Relays & Coax Switch

    For applications where no failure rate is acceptable, Teledyne Relays offers high-performance switching solutions that meet the stringent requirements of aerospace applications. EMR, Coax Switches, and MSSR product lines have been designed for use in space, and are thoroughly tested and screened at the highest levels to ensure optimal performance. ​

  • Measuring and Monitoring Relays

    Bender Inc.

    Various measuring and monitoring relays are available for the purpose of monitoring electrical quantities. In addition to overvoltage, undervoltage, frequency, unbalance, phase sequence, phase failure and loop monitoring, special solutions for specific applications are also possible: extended temperature ranges, sector-specific standards, compact design, country-specific profiles.

  • Protective Relay Testing

    Manta Test Systems

    Choose from Doble’s F6300e and F6350e External Amplifiers for your specific protection testing needs and requirements. These amplifiers are useful in high power protection testing applications when you need additional current and/or voltage sources, for critical high burden relay testing, as well as system modeling.

  • Measuring & Monitoring Relays

    Mors Smitt Group

    XM-series modular electronic monitoring relays *Voltage montoring models (1-phase or 3-phase) *3-phase network monitoring models (phase failure, sequence and asymmetry) *Current monitoring models (AC, DC) *Suited for 35mm rail (DIN) mountingFor general purpose, industrial applications, switching of AC or low DC voltages / resistive loads.

  • Analog Meter Relays

    Hoyt Electrical Instrument Works Inc.

    Hoyt Transistorized Contactless Meter Controllers are complete, self-contained, compact instruments. The CMT Series has a variety of styles and sizes to meet your specific application requirements. These precise instruments continuously indicate any electrical variable. They provide reliable control in a single, self-contained unit, or optionally, a panel-mounted meter with remote amplifier and output relays.

  • Relay Testing Kits

    KINGSINE Electric Automation Co., Ltd.

    Universal Relay Test ApplicationsComplied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc100/1000Mbit Fiber port for SMV and GOOSE simulations6x35A & 4x310V independent high burden output channels13 channels independent low-level signal outputsAC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)Transducer calibration (0.02 class)

  • Automatic Relay Tester

    NRTS-306 - Neutronics Manufacturing Co.

    Model ‘ DY1200 ’ is an ideal, newly developed multifunction relay tester adopting monolithic computer technology. It is composed of auto synchronized digital millisecond timer, logic controlling unit, multifunction digital display, high precision digit collection and processing unit, current-voltage output unit, overload and over range protection unit. Test process is automatic for improved efficiency.

  • Digital Meter Relay

    CSS-4/5 - Chuan Sheng Electronics Co., Ltd.

    ● Measuring DCA, DCV, ACA, ACV, Hz● Process signal mA, Vdc, Strain Gauge, Potentiometer, Pt100Ω● High accuracy and resolution● User function, easily programmed from the front panel by push-button, and set-point by Dip-Switch● Modular design, and popular input range programmable● Three relay ( Hi / Low / Go ) outputs● Optional excitation supply available

  • Relay Testing System

    UNO - EUROSMC, S.A.

    With high power outputs package in an extremely compact and rugged system, the UNO has a tremendous power-to-weight ratio. The design incorporates the latest in modern digital microprocessor technology to achieve unbeatable output characteristics in terms of power, accuracy, low distortion, and dynamic capability. This hi-tech solution enables the testing of many different functions required in relay testing without the need of additional accessories.

  • Automatic Relay Tester

    DYR-II - Neutronics Manufacturing Co.

    Model ‘DYR-II’ is an ideal, newly developed multifunction relay tester adopting monolithic computer technology. It is composed of auto synchronized digital millisecond timer, logic controlling unit, multifunction digital display, high precision digit collection and processing unit, current-voltage output unit, overload and over range protection unit. Test process is automatic for improved efficiency. The tester has a built in printer for printing the results.

  • Relays & Switches - Packaged-InP

    Teledyne Defense Electronics Relays & Coax Switch

    Teledyne Relays' packaged SPDT Indium Phosphide Active RF Switches provide low insertion loss and high linearity, with bandwidths from DC​ up to 60GHz. These switches also maintain excellent signal integrity beyond 40Gbps, and have a very compact package size of 3mm x 3mm x 1mm. Teledyne​'s Active RF​​ switches are ideal for test and measurement systems, microwave communication, and radar applications. ​

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.