40-580-001 -
Pickering Interfaces Ltd.
The 40-580 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 32x8 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
K-1000 Resistive/Reactive -
Kongter Test & Measurement Co., Limited
Resistive/reactive load banks are great choices for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others. A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage.
-
MK Test Systems Ltd.
These specialist Automeg models test the function and integrity of wiring harnesses combined with active components such as relays, switches, contactors, diodes, LEDS, actuators and other active components.Our software takes the complex and traditionally long task of creating functional tests away from the test engineer and allows these to be created automatically, from existing ECAD data and our component library and automated software routines. All the different routes and subtests are automatically calculated in seconds.
-
40-873-002 -
Pickering Interfaces Ltd.
The 40-873-002 is a 4 to 1 RF MUX with 2 banks in a single PXI slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
Mors Smitt Group
Operating records for overhead power lines reveal that most faults are of a transient nature (e.g. lightning induced) & that service interruptions may be minimized by use of automatic reclosing of circuit breakers. An automatic reclosure of the circuit breaker, after the fault clears, provides improved service continuity & system stability. The 1B230 Series Reclose Relay provides for single or double shot automatic reclosing of circuit breakers, following interruption of supply due to a fault in the system.
-
40-873-102 -
Pickering Interfaces Ltd.
The 40-873-102 is a 4 to 1 RF MUX with 2 banks in a single PXI slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
ABB Ltd.
Test switches are designed and manufactured to allow quick and easy multi-circuit testing of switchboard relays, meters and instruments by any conventional system.These test switches and related test plugs have the features necessary for applications involving the measurement of individual currents and voltages associated with substation instrumentation and protection devices. They have been especially designed for the measurement of potential elements, current elements, and make-before-break short-circuit elements related to Current Transformer (CT) circuits.
-
SecuControl inc.
FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.
-
ProDAQ 6140 -
Bustec Ltd.
The ProDAQ 6140 provides a relay matrix which can be fitted between the sensors and actuators on a device under test and the data acquisition and control system. It allows to separately connect/disconnect the signals from either side and to connect them to an internal bus. In this way signals can be routed via the bus to new destinations or the bus can be used to monitor or supply test signals. This allows calibrating and debugging the system without disconnecting and separating channels throughout the system wiring.
-
PCIe-7432 -
ADLINK Technology Inc.
ADLINK PCIe-7432 is a 32CH Isolated DI & 32CH Isolated DO PCIe Card, featuring robust 2,500V isolation protection, suitable for most industrial applications. Input range up to 24V makes it easy to acquire status of external devices (PCIe-7432HIR output range is from 5 to 35V), making it suitable for relay driving and industrial automation applications. Also provided are two easily configurable interrupt sources on digital input channels.
-
782385-13 -
NI
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-14 -
NI
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
ABex TM-1149Cx-FXT -
Konrad Technologies GmbH
The ABex TM-1149Cx-FXT is an ABex terminal module for the Göpel Boundary Scan Controller SFX/PXI(e) 1149/C4-FXT-X. It is connected to the BSCAN-Controller with an adapter-paddle-card.In combination with the above Göpel Boundary scan card it’s possible to connect up to four JTAG/Boundary Scan TAPs. All differential signal wires on the PCB are impedance controlled. In addition, all other digital signals (PIP, TRG, Aux, I/O) and Ground can be switched off via relays.
-
ABex TM-JT37x7 -
Konrad Technologies GmbH
The ABex TM-JT37x7 is an ABex terminal module for the JTAG Technologies Boundary Scan Controller PXI/PXIe JT 37×7. In combination with the JT 2147/ABex from JTAG Technologies it integrates the POD functionality into the module.In combination with the PXI/PXIe JT 37×7 and the JT 2147/ABex it’s possible to connect up to four JTAG/Boundary Scan TAPs. All signal wires on the PCB are impedance controlled. In addition, all signals can be switched off via relays.
-
MODEL DPM-3 -
Transducer Techniques, Inc
The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.