Filter Results By:

Products

Applications

Manufacturers

Relay

electromechanical or semiconductor switches.

See Also: General Purpose Switch


Showing results: 3466 - 3480 of 4056 items found.

  • Ethernet To Parallel Digital Interface Boards

    ICS Electronics

    ICS's Ethernet Parallel Digital Interface boards provide the user with a wide range of IO signals that can be user configured to match virtually any application. These Ethernet boards are available with high power relay driver boards and with optional firmware designed to simplify switching applications. The 80x3 boards have high-power TTL signals that can sink 48 mA and source 24 mA. Pullup resistors make it easy to interface with CMOS logic and to sense contact closures. User configures data byte direction and polarity. The 80x3 boards are VXI-11 compliant for operation with NI or Agilent VISA, LabVIEW and VEE and support raw socket connections. The new 8113 board is a CMOS close of the 8013 board with user set 3.3 or 5 V logic levels. Pinouts and command set is the same as the 8013 board. The 8113 communicates with TCP/IP(Raw Socket) protocoland and also has a RS-232 Serrial Port. All boards are designed for mounting against the rear panel or inside a chassis and use our Ethernet Wiring Kit for easy connection to a Ethernet Connector on the rear panel.

  • High Voltage Isolator for Logic Analyzers

    LX-08 - Link Instruments

    The LX-08 series of high voltage logic analyzer adapters provides a safe isolated method of measuring high voltage control signals with a low voltage logic analyzer. All inbound signals are optically isolated and attenuated to a safe level for the delicate inputs typically found on logic analyzers. The inputs on the LX-08 are capable of withstanding voltages up to +/- 300V AC/DC, higher voltage configurations are available upon request. Rather than probing with multiple neon screwdrivers, the LX-08 can provide simultaneous viewing of up to 8 circuits in the STANDALONE mode via the indicator array. Need to catch a transient event or map out a timing sequence? Just add a logic analyzer to the outputs of the LX-08 and turn it into a high voltage logic analyzer. High voltage signals that were hazardous for a logic analyzer can now be measured safely. Typical outputs of a high speed PLC sequencer can be precisely timed and measured from both sides of the control relay. With the built in user selectable AC filter circuit, an AC signal can be measured as DC events or AC cycles.

  • Load Cell Transmitter

    MODEL SST-HV - Transducer Techniques, Inc

    The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.

  • Load Cell Transmitter

    MODEL SST-LV - Transducer Techniques, Inc

    The SST-LV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-LV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-LV may be powered from 12-30 Vac or 10-48 Vdc. The SST-HV Has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.

  • High Voltage Switching Systems

    HXV Series - Cytec Corp.

    HXV products are high voltage systems intened for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Stand HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2x4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banaba jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.

  • Digital Micro OHM Meter

    Neutronics Manufacturing Co.

    NMC's Digital Micro Ohm Meters are low cost, compact, light weight, 3½ digit resistance meter suitable for measurements of resistances of cables, wires, transformers, motor windings, coils and contact resistance of switches, connectors, relays and track resistance of PCB's etc. The value of resistance is displayed on 7 segment LED display. Four terminal measurement systems provide measurements free from errors due to contact resistance and test lead resistance.

  • Digital Panel Meter

    MW(Q)-5A - Chuan Sheng Electronics Co., Ltd.

    Mx-5A meter to provide power (Watt or Active Power or Re-active Power or Power Factor), high-precision measurement, display and remote communication capabilities.Additional purchase: 1 group of relay outputs, 1 analog output, an RS485 communication output (the Modbus RTU Mode) interface, so that can be installed in power management, remote input and output, alarm and variety of remote communication control the use of needs.120mm (D) is ideal for assembling in panels with limited penetration depth.

  • Digital Panel Meter

    MPF-5A - Chuan Sheng Electronics Co., Ltd.

    Mx-5A meter to provide power (Watt or Active Power or Re-active Power or Power Factor), high-precision measurement, display and remote communication capabilities.Additional purchase: 1 group of relay outputs, 1 analog output, an RS485 communication output (the Modbus RTU Mode) interface, so that can be installed in power management, remote input and output, alarm and variety of remote communication control the use of needs.120mm (D) is ideal for assembling in panels with limited penetration depth

  • 10 Digit Rate/Batch Counter (Analogue)

    CS2-TM-Analogue - Chuan Sheng Electronics Co., Ltd.

    The CS2-TM Totalizer controller provide high accuracy measurement, display, control and communication (Modbus RTU mode) of 0~10V/4~20mA from flow meter or mV from Shunt for Amp-Hour.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.

  • PXI Single 8x2 1-Pole 10A Power Matrix

    40-551-002 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI 2A Multiplexer, 4-Bank, 4-Channel 8-Pole

    40-614-009 - Pickering Interfaces Ltd.

    The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.

  • PXI 2A Multiplexer, 2-Bank, 8-Channel 8-Pole

    40-614-013 - Pickering Interfaces Ltd.

    The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.

  • PXI 2A Multiplexer, 1-Bank, 16-Channel 8-Pole

    40-614-018 - Pickering Interfaces Ltd.

    The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.

  • PXI 2A Multiplexer, 4-Bank, 32-Channel 1-Pole

    40-614-006 - Pickering Interfaces Ltd.

    The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.

  • PXI 2A Multiplexer, 1-Bank, 4-Channel 32-Pole

    40-614-020 - Pickering Interfaces Ltd.

    The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.

Get Help