Showing results: 3811 - 3825 of 4056 items found.
-
SHI Series -
Teledyne Defense Electronics Relays & Coax Switch
Your product description goes here.Series SHI relays are designed to switch high voltage (high power) DC loads. These devices feature the latest generation of High Voltage IGBT Technology. This SSR comes with built-in Diagnostic features. The SHI Series is built with many protection features including protection for transient voltage bursts, overload and short circuits of the load.Available options include:SHI75DC50-6 50A, 750 Vdc Load; 24-48 Vdc ControlSHI75DC50-9 50A, 750 Vdc Load; 72-110 Vdc Control
-
CM1-CT -
Chuan Sheng Electronics Co., Ltd.
CM1-CT multifunction counter(position) display controller, is design to have 2 pulse input, for proximity switch, photoelectric sensor, encoder etc.. Counting increase or decrease, positioning batch count etc.. display, with External input and Modbus communication port.Multiple types of input mode, trip mode setting to fulfil easy usage and requirement for counter controller. For different requirement, the meter can be with 2 relay or 1 Analogue output or 1 RS485(Modbus RTD mode) communication. (Choose 1 kind of output from the 3 options)
-
CS2-VA -
Chuan Sheng Electronics Co., Ltd.
CS2-VA Voltage/Current Meter is designed with high accuracy measurement, display and communication of 0~600V or 0~10A for DC/AC/TMRS.● ADTEK builds flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also build in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.
-
CS2-RL -
Chuan Sheng Electronics Co., Ltd.
CS2-RL RPM Indicator has been designed with high accuracy measurement, display and communication of pulse (Frequency).The innovation feature is auto-range input from 0.01Hz~ 100KHz (option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of testing and machinery control applications.
-
Pickering Interfaces Ltd.
Our LXI modular chassis are available in 7-slot or 18-slot and support over 1,000 of our PXI modules, additionally our 2-Slot USB/LXI Chassis allows most of our 1 or 2-slot PXI modules to be controlled via USB or Ethernet. These range from: PXI general purpose relays, matrices, multiplexers and RF switches to special PXI switching functions such as fault/signal insertion. Also supported are a selection of T&M modules such as programmable resistors, digital I/O, power supplies, battery simulators and attenuators.
-
40-549-001 -
Pickering Interfaces Ltd.
The 40-549 is a single pole power matrix module, suitable for switching inductive/capacitive loads up to 5A with 110VDC/250VAC hot switching and 400VDC/250VAC cold switching. It is available in single 16x4, single 8x8, dual 8x4 or single 8x4 configurations. Connections are made via a front panel 25 way D-type male connector. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. The module is suitable for applications requiring switching of either mains voltage or DC current.
-
40-662-002 -
Pickering Interfaces Ltd.
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
40-523-021-S -
Pickering Interfaces Ltd.
The 40-523 module is configured as a 44x4 high density matrix with available reedrelay formats of 1-pole, 2-pole and 1-pole screened. The screened version is suitablefor switching signals up to 50MHz. Model 40-524 is a similar matrix, available insingle pole 46x4 format. Typical applications include signal routing in FunctionalATE and data acquisition systems. These PXI matrix cards are constructed using highreliability Ruthenium Electro-Plated Reed Relays, offering >10e8 operations togive maximum switching confidence with long life and stable contact resistance.
-
40-662-012 -
Pickering Interfaces Ltd.
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
40-662-003 -
Pickering Interfaces Ltd.
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
40-662-013 -
Pickering Interfaces Ltd.
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexers. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
40-662-001 -
Pickering Interfaces Ltd.
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
40-662-014 -
Pickering Interfaces Ltd.
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
40-662-011 -
Pickering Interfaces Ltd.
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
MagD -
Scope T&M Pvt, Ltd.
SCOPE proudly introduces Step-Up Transformer - MagD, specially designed to cater the needs of testing of instrument Transformers. Before new systems are put into service or after any occurrence of fault, the instrument transformers need to be tested for their outputs. It is to be ensured that these instrument transformers are giving proper outputs to the protective relays. MagD is used to plot excitation curves for instrument transformers. Inbuilt voltmeter and ammeter, eliminates the need of external meters for plotting of curves. It can also be used for de-magnetization of transformer cores and also turns-ratio tests can be conducted using MagD.