Filter Results By:

Products

Applications

Manufacturers

Welding

bonding together by melding.

See Also: Weld


Showing results: 76 - 77 of 77 items found.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TT Series - IBEKO Power AB

    RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • All in one system 32KWH LiFePO4 Lithium Battery with AC Charger and 15KW Inverter for mobile vehicle application

    SPVLI-32KWH-INV15KW - Zhejiang Sandi Electric Co., Ltd

    Our All in one system 32KWH LiFePO4 Lithium Battery with AC Charger and 12-15KW 120/240V Inverter for mobile vehicle application ESS including LiFePO4 Lithium Battery with BMS, off grid pure sine wave inverter, AC/DC charger.All-in-one design, high integration and space saving installation;Using high-performance lithium iron phosphate cells, laser welding, good cell consistency, designed service life of more than 10 years; Charging and discharging are controlled separately, which is convenient and reliable to control charging and discharging. The discharge port will not be disconnected when over-charging, and the charging port will not be disconnected when over-discharging, the system has good stability;Master-slave mode, passive equalization, can manage the equalization resistance, can set the equalization start voltage difference, and monitor the equalization resistance temperature, more intelligent and safe, and reduce the impact of barrel effect on system energy storage;BMS adopts NXP(USA) automotive-grade high-performance chips, with strong anti-interference, good reliability and wide temperature range;CAN2.0 communication interface, has the advantages of strong real-time performance, long transmission distance, strong anti-electromagnetic interference ability;System parameters can be set through the host computer, such as fan start/stop temperature, charger maximum current setting, charge and discharge current correction, SOC correction, with insulation leakage detection function to prevent oil leakage and short circuit of the cell;Integrate Solar charge controller or AC charger optional, BMS communication control, more safe and reliable;Cell temperature management, can be automatically controlled with the air conditioner heater according to the cell condition to make the cell works at the most suitable temperature, and can be linked with the fire protection system as neededModel SPVLI-30KWH-INV12KWIsolation mode Low Frequency TransformerInverter PartBattery Input Rated Voltage (Vdc) 307VDC Voltage range (Vdc) 278-400VAC Output Rated output power 12KW Output waveform Pure Sine Wave Rated Voltage 120/240VAC Phases Split phase + N + PE Rated current (A) 50A(Phase Current) Frequency 60Hz Power Factor (PF) >0.95 Inverter Efficiency >92% Display LCD Overload Ability 150%, 35 secondsAC-DC Charger PartAC Input Voltage range(Vac) 180-240VacDC Output Rated voltage(Vdc) 330Vdc Rated current(A) 20ALithium Battery PartCell/Number 105AH/96PCSRated voltage 307VMax charge current 20AMax discharge current 100ACharge temperature range 0℃ ~ 50℃Discharge temperature range -20℃ ~ 50℃Cell charge end voltage 3.6VCell discharge end voltage 2.7VProtection Function Protection Input reverse polarity, under voltage, over voltage, output over-current, short circuit, overheating etc. Cooling method Fan-cooledDegree of protection IP20(indoor)Mechanical Dimension Depth* Width * Height 645x891x767mm Weight (Kg) 378Kg

Get Help