  • PXI-5114, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope, 64 MB

    779466-02 - NI

    125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope—The PXI‑5114 low-cost PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require flexible measurement configurations and up to 125 MHz of analog bandwidth. The PXI‑5114 also features PXI synchronization and data streaming capabilities.

  • PXI-5114, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope, 256 MB

    779466-03 - NI

    125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope—The PXI‑5114 low-cost PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require flexible measurement configurations and up to 125 MHz of analog bandwidth. The PXI‑5114 also features PXI synchronization and data streaming capabilities.

  • PXI-5114, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope, 8MB

    779466-01 - NI

    125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope—The PXI‑5114 low-cost PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require flexible measurement configurations and up to 125 MHz of analog bandwidth. The PXI‑5114 also features PXI synchronization and data streaming capabilities.

  • PXI-5105, 60 MHz, 8-Channel, 12-Bit PXI Oscilloscope

    779685-02 - NI

    60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXI‑5105 high-density PXI oscilloscope device has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXI‑5105 also features PXI synchronization and data streaming capabilities.

  • PXI-5105, 8-Channel, 12-Bit, 60 MHz PXI Oscilloscope

    779685-01 - NI

    60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXI‑5105 high-density PXI oscilloscope device has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXI‑5105 also features PXI synchronization and data streaming capabilities.

  • PXI-5105, 60 MHz, 8-Channel, 12-Bit PXI Oscilloscope

    779685-03 - NI

    60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXI‑5105 high-density PXI oscilloscope device has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXI‑5105 also features PXI synchronization and data streaming capabilities.

  • PXIe-5105, 60 MHz, 8-Channel 512 MB, 12-Bit PXI Oscilloscope

    783590-03 - NI

    PXIe, 60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXIe‑5105 high-density PXI oscilloscope has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXIe‑5105 also features advanced PXI synchronization and data streaming capabilities.

  • PXIe-5105, 60 MHz, 8-Channel 16 MB, 12-Bit PXI Oscilloscope

    783590-01 - NI

    PXIe, 60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXIe‑5105 high-density PXI oscilloscope has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXIe‑5105 also features advanced PXI synchronization and data streaming capabilities.

  • PXIe-5105, 60 MHz, 8-Channel 128 MB, 12-Bit PXI Oscilloscope

    783590-02 - NI

    PXIe, 60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXIe‑5105 high-density PXI oscilloscope has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXIe‑5105 also features advanced PXI synchronization and data streaming capabilities.

  • Hardy Shaker

    HI-903 - Metrix

    This is our top of the line Hardy Shaker. It provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting vibration tests easier. Tests can be conducted on multiple vibration transducers, and then the saved data can be transferred via USB Flash Drive to be displayed in an automated and customizable report using an Excel template on your computer. In manual mode, the vibration test level and test frequency can be set from 7 Hz to 10,000 Hz. The high accuracy instrument can display the vibration level in terms of g’s peak, velocity peak (in/sec or mm/s) or displacement peak-to-peak (mils or µm). The unit can support payloads up to 800 grams (see frequency limits in the manual). A built-in display reads the output sensitivity, which can be stored in memory. Complete testing sequences and data can be stored in memory for each tested sensor, the unit logs the data on the spot or stores it for later use. For testing of heavy transducers or at high frequencies, the HI-903 automatically corrects the sensitivity calculation for the effects of transducer mass loading. A built-in self-test program checks for accuracy of all calculations. The HI-903 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • Smoke Detection Sensor – 120VAC Wire-In with Battery Backup

    ENVIROMUX-SDS-120V - Network Technologies Inc

    For warning of smoke and invisible fire particles. Ionization smoke detector. Applications from 40°F to 100°F (4°C to 38°C). Front loading battery door. 9V battery backup (included) in case of power failure. One button design for easy testing and HUSH mode activation control. LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode. Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours. Voltage supply: 120VAC. Pre-stripped wiring harness with tinned strands. Audio alarm: 85dB at 10ft. Dimensions: 5" diameter x 1.75" depth. Dust cover prevents false alarms. Tamper resist feature. Links with up to 24 devices. Max distance between first and last device: 1000ft (305m). Alarm memory indicates initiating alarm in interconnected systems. Use compatible relay (ENVIROMUX-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting. ENVIROMUX-RLY-SDS120V includes normally open and normally closed contacts. Contact ratings: 10A at 120VAC, 5A at 30VDC. Regulatory approvals: UL.

  • Circuit Breaker Analyzers & Timers

    CAT Standard Series - IBEKO Power AB

    Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.

  • LVDS Digital I/O with Virtex-6 FPGA - 6U VPX

    Model 58610 - Pentek, Inc.

    - 32 or 64 bits of LVDS digital I/O- One or two LVDS clocks- One or two LVDS data valid- One or two LVDS data suspend- Supports LXT and SXT Virtex-6 FPGAS- One or two DMA controllers move data to and from system memory- Up to 2 or 4 GB of DDR3- PCI Express (Gen. 1 & 2) interface up to x8- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O to the carrier board- Ruggedized and conduction-cooled versions available

  • LVDS Digital I/O with Virtex-6 FPGA - 6U VPX

    Model 57610 - Pentek, Inc.

    - 32 or 64 bits of LVDS digital I/O- One or two LVDS clocks- One or two LVDS data valid- One or two LVDS data suspend- Supports LXT and SXT Virtex-6 FPGAS- One or two DMA controllers move data to and from system memory- Up to 2 or 4 GB of DDR3- PCI Express (Gen. 1 & 2) interface up to x8- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O to the carrier board- Ruggedized and conduction-cooled versions available

  • Resistance Meter - Portable, Precision Resistance Measurement from 0.10 to 1.00 x 10^12 Ohms

    PRS-812B - Prostat Corporation

    - Wide Range Resistance: 0.10 Ω to 1.00x1012 Ω- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Constant Test voltages 10V and 100V for specification measurements to meet international and domestic ESD measurement standards- Auto Resistance Range Control- Auto Test Voltage Control- Uses a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- 120 Data Set Internal Memory- Uses Standard USB Cable for Charging- Charges in 2 Hours- 2-year Limited Warranty on Main Instrument