Filter Results By:

Products

Applications

Manufacturers

Illumination

the effect of lighting.

See Also: Light, Lighting, Lightning, Lightwave, Daylight, Streetlight, Illuminance Meters, Illuminance, Illuminators


Showing results: 166 - 180 of 187 items found.

  • Thermal Night Vision Rifle Scope

    ThermoSight® R-Series - Teledyne FLIR

    Built by the leader in infrared technology, the FLIR ThermoSight R-Series is the world''''s first line of thermal night vision rifle scopes for non-game hunting starting under $3,500. Compact and easy-to-use, the ThermoSight R-Series combines the features you want with the thermal performance you expect. The ThermoSight R-Series is the ideal night vision scope because it detects heat energy, instead of light. Conventional image intensified (I2) night vision scopes require illumination from moonlight or other sources, and can''''''''t reveal what''''''''s hiding in the shadows or in low-contrast environments like the R-Series.

  • Phase Indicators

    Kyoritsu Electrical Instruments Works, Ltd.

    New technology permits safe testing, without the need of direct contact between probes and live wires. The insulated crocodile clips can clip insulated cables from 2.4 to 30mm. Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones. The instrument can be fixed to a metal panel via the magnet on the back side. Wide measuring range for 3 phase installations from 70V to 1000V AC. Super brightness function permits clear LED''''s indication also in sunshine. Complies with IEC 61010-1 CAT IV 600V and CAT III 1000V.

  • 3D Micro Coordinate Measurement Machine and Surface Roughness Measurement Device

    InfiniteFocusSL - Alicona Imaging GmbH

    With the InfiniteFocusSL you are able to measure form and roughness of your components with only one system. In addition, color images with high contrast and depth of focus are achieved. The robust frame and the intelligent illumination technology provide fast and high-resolution measurement in the laboratory and a production near environment. The measurement system is particularly attractive due to its cost effectiveness, measurement speed and usability. The long working distance in combination with the above average measurement field allows a wide range of applications. Measurements are achieved within seconds, and features, such as a coaxial laser for quick and easy focusing, enhance its usability.

  • Light Meter - Digital and Analog display of light in Foot-candles or Lux

    Extech LT300 - Extech Instruments Corporation

    Insufficient lighting can create security risks or result in OSHA crackdowns. The Extech LT300 light meter can determine whether you have adequate illumination to protect workers, students, visitors, patients or attendees of different venues. This handheld instrument measures up to 40,000 Fc (or 400,000 Lux) utilizing a remote light sensor connected via 12 in. coiled cable (expandable to 24 in.). A prominent LCD readout displays a digital calculation and complementary analog bar graph for quick, reliable assessments. Complete with 9V battery, light sensor with protective cover, protective holster, and soft case.

  • Climatic Test Chambers

    Dongguan Amade Instruments Technology Co., Ltd

    Climatic test chambers are also referred as environmental test chambers, which is the general name of various test chambers that simulate the natural climate environment of raining, high temperature, low temperature, constant temperature, illumination, dewing etc, products including constant temperature chamber, constant humidity chamber, ozone aging test chamber, UV accelerated weathering tester, vacuum hot air oven, salt spray chamber, steam aging tester, rain test chamber, dust proof test chamber, ventilation aging chamber, xenon lamp weathering test chamber and so on.

  • Laser Distance Meter

    KM 973 - Kusam Electrical Industries Limited

    • Measuring Range : 0.05 to 40M (KM 973) , 0.05 to 70M (KM 975), 0.05 to 100M (KM 976) • Measuring Accuracy : ± 2 mm• Display Accuracy : 1 mm• Laser Classification : Class 2M II• Laser Type : 620-690nm, <1mW• Protection against splashes and dust : IP 54• Temperature range for Operation : 0°C to +40°C• Temperature range for Storage : -20°C to +70°C• Laser Switch-OFF Automatically : After 30 Seconds• Instrument Switch-OFF Automatically : After 3 Minutes• Area, Volume Measuring.• Indirect (Pythagoras) Measurement.• Plus-Minus Method.• Continuous Measurement.• Minimum / Maximum Measurement.• Display illumination.• Show beep.• Battery Life : 5000 to 8000 Measurements• Battery Selection : Lr6 (AA) 2 x 1.5V• Dimensions : 121(L) x 56(W) x 28(H) mm• Weight : 150g

  • AFM (Atomic Force Microscope) Optical Platform

    HORIBA, Ltd.

    The AFM platform allows fully-integrated use of confocal Raman microscopy and AFM for Tip-Enhanced Optical Spectroscopies (such as Tip-Enhanced Raman Spectroscopy (TERS) and Tip-Enhanced PhotoLuminescence (TEPL)), but also for truly co-localized AFM-Raman measurements.The myriad of AFM (Atomic Force Microscope) techniques that allow study of topographical, electrical and mechanical properties can be performed with any laser source available in Raman spectrometer, or with other external illumination (e.g., solar simulator or other tunable or continuum source). TERS and TEPL can provide nanoscale chemical and structural information, making the AFM-Raman platform a two-way road; where complimentary techniques provide novel and unique imaging capabilities to each other.

  • Light Sources

    Inframet

    There are many low cost artificial light sources used for illumination or for industrial applications: tungsten or halogen bulbs, fluorescent lamps, LED lamps etc. Some of these sources have regulated intensity of emitted light. However, there very few calibrated light sources of precisely known parameters. A light source can be considered as calibrated when its user can precisely regulate its photometric/radiometric parameters like luminance (or illuminance), radiance (or irradiance) at defined spectrum of interest. Such light sources are needed in many applications among them, in systems for testing night vision devices, VIS-NIR cameras and SWIR imagers. Inframet offers a series of calibrated light sources that can be divides into three groups:

  • Enhanced UV Light Source

    Model 30E - OAI

    The Model 30E Enhanced UV Lightsource is highly efficient and may be utilized in a variety of applications. Light is collected by an ellipsoidal reflector and focused on an integrating/condensing lens array to produce uniform illumination at the exposure plane. This UV light source is available in various beam sizes up to 24 inches square with output spectra ranging from 220 nm to 450 nm, using the appropriate lamp (included). Output power ranges from 200 watts to 5 kilowatts. All OAI UV Lightsources are easily equipped with quick-change filter assemblies, enabling the user to customize the output spectrum with little effort. Optional remote exhaust fans are available.

  • Adjustable Length Linear Backlight, 300 mm to 2100mm

    Vitech A1905 - ViTec Co. Ltd

    Modules A1905 are designed for pulsed or continuous illumination of objects in machine vision systems. The time of ignition (90%) and blanking (10%) of the module is less than 1 μs with jitter of the front(jitter) no more than 2 μs, which allows the modules to be used for exposure with "slow" cameras.The control input is compatible with npn, pnp, "open collector", TTL, LVTTL, RS422 (Basler racer) outputs.Modules can be made with light-emitting diodes of the following colors:Infrared - wavelength 730 or 850 nm;Red - wavelength 620-630 nm;Green - wavelength 520-530 nm;Blue - wavelength 460-470 nm;Ultraviolet - wavelength 365 or 400 nm;White - with a color temperature of 5000K.

  • Biconic Logarithmic Periodic Antennas

    Stacked LPDA - Schwarzbeck Mess Elektronik

    The stacked Logarithmic Periodic Dipole Antenna consists of two ordinary Log.-Per. structures. The excellent characteristics (flat gain over a large bandwidth, low SWR) of the ordinary Log.-Per. designs could be maintained using the stacked LP design. The stacked design helps to focus the directional pattern of the H-plane somewhat, resulting in a typical gain improvement of ca. 2-3 dB compared to an ordinary LPDA. This is especially important for immunity testing, where a maximum fieldstrength and a good field uniformity is required. The beamwidth in the E-plane and the H-plane are nearly identical, providing an optimised illumination of the EuT with minimised ground reflection influence. Further the STLP 9128 C has an excellent cross-polar rejection.

  • Solar Simulation Systems

    Photo Emission Tech., Inc.

    PET Solar Simulators consist of a Light Source with a built-in Lamp Power Supply. The Solar Simulator has an ellipsoidal reflector that surrounds the lamp and collects most of the lamp output. The radiation from the lamp is focused onto an optical integrator that helps produce a uniform diverging beam. The beam is diverted 90° by a mirror onto a collimating lens. Special filters are placed between the mirror and the collimating lens to shape the radiation spectra to match various air masses. The output is a uniform beam that closely matches the sun's radiation spectra for a given air mass. Various models offer different areas of illumination. Each model can be manufactured to simulate the sun's radiation for different air masses.

  • Digital Video Microscope

    BVM-1010 - BYC Industrial Ltd

    M-LCD Video Microscope has renovated the traditional way of microscopic observation and adopted a modern way of electronic imaging. This patented microscope makes the observation more comfortable and thoroughly resolves the fatigue caused by using a traditional microscope at work for a long time. It features high performance of CCD image capturing, high resolution of LCD display and reverting genuine images. Based on 2D observation, 3D angle attachment is added to obtain 3D multi-angle observation. Laser locating function can easily identify the position of observation. This unit integrates magnification, imaging, display, LED illumination and laser locating functions. Compact design, light weight and low power consumption make the operation simple and convenient. M-LCD Video Microscope can be conveniently applied to testing and inspecting in product assembly, research and teaching fields.

  • Compact Antenna Test Range

    700.00 MHZ – 110000.00 MHZ - MVG

    A Compact Antenna Test Range (CATR) allows electrically large antennas to be measured at a significantly shorter distance than would be necessary in a traditional far-field test range. Compact ranges use a source antenna (feed) to radiate a spherical wave in the direction of a parabolic reflector, collimating it into a planar wave for aperture illumination of a Device under Test (DUT). It's lowest operational frequency is determined by the size of the reflector, its edge treatment and the absorbers. The two edge treatments available are serrated edge for general purpose applications, and rolled edge to achieve higher accuracy for special applications. Multiple-feed systems may be used to improve the far-field characteristics. A compact range test system also allows system level testing of a complete device architecture.

  • Multi Function Testers

    Kyoritsu Electrical Instruments Works, Ltd.

    Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs

Get Help