Showing results: 31 - 45 of 53 items found.
-
E1834J -
Keysight Technologies
The E1834J is a 67% beam splitter in a high performance horizontal mount that offer the high pointing stability for Keysight laser interferometer measurement system. The 8 flexure feet are designed for stable beam pointing.
-
5517FL -
Keysight Technologies
The Keysight 5517FL is used primarily in VME and PC based laser interferometer systems where the velocity of motion is faster, such as semiconductor lithography and flat panel applications. Please contact Keysight for custom requirements.
-
5517EL -
Keysight Technologies
The Keysight 5517EL is used primarily in VME and PC based laser interferometer systems where the velocity of motion is faster, such as semiconductor lithography and flat panel applications. Please contact Keysight for custom requirements.
-
10785A -
Keysight Technologies
The Keysight 10785A Height Adjuster and Post is used to precisely position optics devices associated with the 5530 Laser Calibration System, such as the 10766A Linear Interferometer. The height adjuster and post also facilitate adjustments in measurements such as pitch and yaw.
-
10780C -
Keysight Technologies
The Keysight 10780C is a highly-sensitive, lowest-cost Keysight receiver used with laser interferometer positioning systems. One receiver is used per measurement axis (including wavelength tracker). Configured with Keysight electronics, laser heads, cables and optics, the Keysight 10780C receiver allows you tailor a precise positioning system for your exact application requirements.
-
55281A -
Keysight Technologies
The Keysight 55281A Angular Optics Kit adds pitch and yaw measurement capability to the 5530 Laser Calibration System. Ideal for use in precision calibration applications, it includes the 10770A Angular Interferometer and the 10771A Angular Reflector. Together the high-accuracy plane mirror interferometer and the angular reflector measure pitch and yaw motions along each axis that a machine tool or measuring machine travels. Results are displayed directly in arc-seconds or in mm/mm (in/in).
-
Pratt & Whitney Measurement Systems, Inc.
The most popular ID/OD instrument in the world. Automatic probe movement with a push of a button. High accuracy is maintained by its laser interferometer, zero Abbe offset design, and large measuring table with swivel, center, tilt, and elevation control knobs.
-
10736A -
Keysight Technologies
The Keysight 10736A Three Axis Interferometer is used in multiple axis applications where linear and angular control of the stage is required. It combines in a single package the functionality of an optical bench with multiple beam benders, beam splitters, and three interferometers. The interferometers split an incoming laser beam into three beams to measure linear distance, pitch and yaw, or linear distance, roll and yaw. Three linear measurements provide the basis for calculating two angular measurements. The inherent beam parallelism ensures that there is essentially no cosine error between the three measurements and also ensures angle accuracy for pitch and yaw measurements. Other characteristics include:
-
10735A -
Keysight Technologies
The Keysight 10735A Three Axis Interferometer is used in multiple axis applications where linear and angular control of the stage is required. It combines in a single package the functionality of an optical bench with multiple beam benders, beam splitters, and three interferometers. The interferometers split an incoming laser beam into three beams to measure linear distance, pitch and yaw, or linear distance, roll and yaw. Three linear measurements provide the basis for calculating two angular measurements. The inherent beam parallelism ensures that there is essentially no cosine error between the three measurements and also ensures angle accuracy for pitch and yaw measurements. Other characteristics include:
-
1200 -
Adcole Corp.
The Adcole Model 1200 Cylindrical Coordinate Measurement Machine (CCMM) is a highly accurate gage for measuring camshafts, crankshafts and other cylindrical parts that feature tight part tolerances. The system employs a proprietary laser interferometer technology to deliver precise radial and length measurements.
-
HighFinesse GmbH
HighFinesse/Ångstrom offers sensitive and compact wavelength meters with a large spectral range for high speed measurement of lasers. The optical unit consists of temperature-controlled Fizeau-based interferometers that are read out by photodiode arrays. The high absolute accuracy is achieved by use of solid state, non-moving optics.
-
10780F -
Keysight Technologies
The Keysight 10780F Remote Receiver with fiber-optic pickup provides maximum layout flexibility for Keysight laser interferometer positioning systems. Remote pickup capabilities allow mounting of the heat-dissipating receiver electronics away from measurement areas, resulting in high measurement stability, accuracy, and repeatability.
-
10897D -
Keysight Technologies
The 10897D High-resolution VMEbus laser axis board provides excellent resolution of up to 0.3 nm with a high resolution interferometer. The data age uncertainty is dramatically reduced allowing extremely accurate measurement and control of moving systems. The very high data rates accommodate high-bandwidth and high-performance closed-loop applications. Configured with appropriate lasers and optics components, the 10897D supplies unsurpassed positioning accuracy for dynamic measurement.
-
10753B -
Keysight Technologies
The Keysight 10753B Tripod provides a mounting for the Keysight 5519A/B laser head. The tripod allows Keysight 5530Laser Calibrationsystem optics to be located remotely from the laser head, yielding greater accuracy and simplifying fixturing. The remote setup also eliminates heat-caused distortions. The Keysight 10753B adjusts for height, rotation, tilt, and lateral offset. The tripod is collapsible, covers a height range of 900 mm (35.5 in) to 1630 mm (64.0 in), and has a net weight of 14 kg (31 lb). The Keysight 10753B tripod complements a family of measurement optics and lasers that comprise Keysight laser interferometer calibration systems.
-
55280A -
Keysight Technologies
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.